3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

never ending problem... electrical issue!

Thread Tools
 
Search this Thread
 
Old 10-06-03, 09:51 AM
  #1  
Senior Member

Thread Starter
 
Cihuuy's Avatar
 
Join Date: Jan 2002
Location: Myanmar
Posts: 658
Likes: 0
Received 0 Likes on 0 Posts
never ending problem... electrical issue!

I have had many problem wiv my car lately... the recent one is the bloody fan fuse!! It not only blown on me once but 3 bloody consecutive time in the past 1.5 month!?!

i know that it is nothing compared as a broken seal or not as painfull as a dying turbo... but driving around WITHOUT your fan working, stress me out!! luckily everytime it happens i paid attention to my gauges! *PHEW*

so at the mean time, i picked upsome spare fuse (60A)just in case it will happens again... but how can i remedy this problem?? any inputs needed
Old 10-06-03, 03:08 PM
  #2  
RX-7 Bad Ass

iTrader: (55)
 
DaleClark's Avatar
 
Join Date: Jan 2002
Location: Pensacola, FL
Posts: 15,399
Received 2,438 Likes on 1,509 Posts
That will likely be a tricky one to find. Probably an intermittent short in the fan wiring - look to see if the harness is rubbed through anywhere.

Dale
Old 10-07-03, 06:03 PM
  #3  
Senior Member

Thread Starter
 
Cihuuy's Avatar
 
Join Date: Jan 2002
Location: Myanmar
Posts: 658
Likes: 0
Received 0 Likes on 0 Posts
i found out that it only happens when i run hard!! i know this because the fuse blew again... i guess your right, DCFC3S. maybe the wiring is lose or rubs again something... *sigh* ill try and take a look
Old 10-08-03, 01:02 AM
  #4  
Full Member

 
twinturboy's Avatar
 
Join Date: Apr 2002
Location: Orlando, Fl
Posts: 171
Likes: 0
Received 0 Likes on 0 Posts
I have dealt with similar electrical problems which kept snowballing on me. It started with my fans acting up, then the turn signals, then the room fuse, then check engine lights, then my computer fried, then I almost thought it toasted my motor. After months of diagnosis, I finally a damaged section of my front harness under the passenger fender liner. Seems the wheel has been rubbing against the harness for the last year or so and slowly cutting and shorting out a bunch of different wires. It was a real pain in the *** to diagnose since I had spent so much time going through wiring diagrams, testing circuits, and not finding my problem. I only luckily spotted one of the frayed wires sticking out Only a few days ago I finally got the car back on the road.

Anyhow, as for your problem, you need to get the service manuals from iluvmyrx7.com and start testing the fan system. You could have a short in the wiring, bad relay, bad fan control module, bad e/l unit. If you have any specific questions about the fan system, I am pretty familiar with it. You can PM me. If all else fails, you can rewire the fans, and any problems in the harness, etc can be bypassed. You can just have a switch to enable the relays. Hope that helps a little.
Aneel
Old 10-08-03, 02:54 AM
  #5  
-

iTrader: (3)
 
rockshox's Avatar
 
Join Date: Nov 2002
Location: SF Bay Area
Posts: 624
Likes: 0
Received 0 Likes on 0 Posts
i kept blowing a fan relay and it was a nearly siezed up fan motor drawing too much current. try to turn your radiator fans by hand with the car off and see if they spin freely.
Old 10-08-03, 04:54 AM
  #6  
Junior Member

 
Join Date: Aug 2002
Location: Southern Hemisphere
Posts: 49
Likes: 0
Received 1 Like on 1 Post
Cihuuy,

Greetings. Heard of a problem similar (but not exactly) like yours here in KL. Apparently the fan wires were somehow "worn" and "rusted". This guy replaced his fan wiring entirely and it worked fine after that. Your relay could have broken due to the regular switching. Hope this helps.

Kace
Old 10-08-03, 06:16 AM
  #7  
Senior Member

Thread Starter
 
Cihuuy's Avatar
 
Join Date: Jan 2002
Location: Myanmar
Posts: 658
Likes: 0
Received 0 Likes on 0 Posts
wow... tanx for the many inputs u guys...

i havent find where the short is... but i tried spinning both of the radiator fan and its spin freely, so it seems the fans are alright.

i might have rubbed some wires when I installed my turbo back, but i dont see how!?! the only way is to take the I.C. and everyting else that covers the fan and inspect from there... hopefully is a minor problem

would collant disintegrated the wires? cz sometimes i overfill the radiator filler neck and tank which is on top of the fan...?
Old 10-09-03, 11:25 PM
  #8  
Junior Member

 
Join Date: Aug 2002
Location: Southern Hemisphere
Posts: 49
Likes: 0
Received 1 Like on 1 Post
Cihuuy,

I get coolant all over my wires and nothing has happened yet to those wires.

Also, what's the cost of parts like in Brunei? I know it's relatively cheap in Kuala Lumpur. Why not just purchase some old fans and just install them in? Don't think your 60A fuses will be that cheap!

Kace
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Th0m4s
Build Threads
25
02-26-19 02:04 AM
C. Ludwig
Single Turbo RX-7's
49
01-30-19 06:31 AM
rexhvn
3rd Generation Specific (1993-2002)
0
08-19-15 02:59 AM
befarrer
2nd Generation Specific (1986-1992)
4
08-14-15 04:18 PM



Quick Reply: never ending problem... electrical issue!