Single Turbo RX-7's Questions about all aspects of single turbo setups.

How to test external wastegate?

Thread Tools
 
Search this Thread
 
Old Mar 13, 2014 | 10:38 PM
  #1  
MuRCieLaGo's Avatar
Thread Starter
Forever blown!
Tenured Member 15 Years
iTrader: (14)
 
Joined: Jul 2007
Posts: 1,370
Likes: 13
From: Trois-Rivieres (QC)
How to test external wastegate?

Having a hard time trying to adjust my boost, it is stuck to 11 psi. Changed boost controller, without any effect. Is there an easy way to test the external wastegate?
Reply
Old Mar 13, 2014 | 10:44 PM
  #2  
Zero R's Avatar
Just in time to die
Tenured Member 10 Years
iTrader: (1)
 
Joined: Nov 2001
Posts: 4,143
Likes: 2
From: look behind you
Manual hand held vacuum/pressure pump with a gauge on it. Mightyvac comes to mind.

~S~
Reply
Old Mar 14, 2014 | 08:19 AM
  #3  
MuRCieLaGo's Avatar
Thread Starter
Forever blown!
Tenured Member 15 Years
iTrader: (14)
 
Joined: Jul 2007
Posts: 1,370
Likes: 13
From: Trois-Rivieres (QC)
I need details!
Reply
Old Mar 14, 2014 | 11:47 AM
  #4  
Zero R's Avatar
Just in time to die
Tenured Member 10 Years
iTrader: (1)
 
Joined: Nov 2001
Posts: 4,143
Likes: 2
From: look behind you
You need a mighty vac. You connect it to the bottom port on the gate and apply pressure with the pump, the gate should open and you will be able to tell when it does by the gauge on the mighty vac.

~S~
Reply
Old Mar 14, 2014 | 03:49 PM
  #5  
cewrx7r1's Avatar
Eye In The Sky
Tenured Member: 25 Years
iTrader: (2)
 
Joined: Feb 2001
Posts: 7,941
Likes: 133
From: In A Disfunctional World
Hook up only the lower-side port to the boost source before the TB which already should be like that. Do not connect the top port hose which is the one used to control boost.
Boost should not go more than 1 psi above the WG spring pressure.

Most likely either your WG setup is wrong or your EBC setup is wrong.

Most of the time operator error is the problem.
Reply
Old Mar 16, 2014 | 08:01 PM
  #6  
MuRCieLaGo's Avatar
Thread Starter
Forever blown!
Tenured Member 15 Years
iTrader: (14)
 
Joined: Jul 2007
Posts: 1,370
Likes: 13
From: Trois-Rivieres (QC)
I don't understand very well so I think I'll go in a local garage, I'm suppose they're able to do it.
Reply
Old Mar 17, 2014 | 08:09 AM
  #7  
0110-M-P's Avatar
Too Many Projects
Tenured Member: 20 Years
iTrader: (10)
 
Joined: Feb 2003
Posts: 1,410
Likes: 2
From: Atlanta, GA
Could you post up a diagram of how you have the vacuum hoses routed between the wastegate, boost controller, and pressure source?

Setting up the vacuum hoses to/from the wastegate isn't all that complex and your problem is probably simple to fix. It is very easy to swap one vacuum hose and completely change how the system functions.