need some figres
#1
Rotary Freak
Thread Starter
Join Date: Jan 2004
Location: tampa
Posts: 1,899
Likes: 0
Received 0 Likes
on
0 Posts
need some figres
had a long dissucsion with the ac delco rep about some heater core warrenty claims we made. long story short they are saying improper grounding which led to electrolysis eating away the welds.
cool car
take a volt meter put the - lead on the - batt terminal
put the pos in the coolant , not touching the metal just coolant
start car and what reading do you get?
turn on all elec loads and what is the reading then?
mine was .002 with no load
and was .039 with full ac etc.. just curious if you can do it and reply thanks. the rep said anything over .2 will quickly eat up a cooling sys. we did have a caddy that read 2.8 volts. 2 ground wires from the radiator and block to body brought it to .027
cool car
take a volt meter put the - lead on the - batt terminal
put the pos in the coolant , not touching the metal just coolant
start car and what reading do you get?
turn on all elec loads and what is the reading then?
mine was .002 with no load
and was .039 with full ac etc.. just curious if you can do it and reply thanks. the rep said anything over .2 will quickly eat up a cooling sys. we did have a caddy that read 2.8 volts. 2 ground wires from the radiator and block to body brought it to .027
Thread
Thread Starter
Forum
Replies
Last Post
rurouni2071
2nd Generation Specific (1986-1992)
5
07-05-07 10:01 PM