Looking for some sound advice:

Just finished installing some upgraded parts - gredddy smic; fluidyne rad, greddy airinx, installed RESpeed Oil pedestal & FC water thermosensor, replaced oil press sender, and also installed 2nd oil press sender and water temp sender.

About 2 weeks ago, just as I was pulling into the office, the stock water temp and oil press gauges went dead. When it was time to drive home, I lost all instrument gauges, warning lights and even odometer. When checking the fuse bank, the Meter Fuse was blown. Replace it and as soon as the car was set to ON, the fuse blew again.

Great, so I have a short on hand. I've been digging thru the schematics searching for shorts but have no luck thus far. I've ohmed out the fan relays, disconnected the cooling fans, removed the alt, disconnected the turbo timer, ohmed out the turn signal switch and the interconnect harness to the turbo timer. So far everything checks good-all 4 relays are normally open and the coils appeared to read 90ohms (except for relay 1 - 75ohms).

Thanks for the help guys!
Reply
Old Jul 30, 2006 | 11:10 PM
  #2  
xcelir8's Avatar
Full Member
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 181
Likes: 0
From: St. Louis
I Had the same problem. I had to tear apart the dash and trace out the wires. It turned out to be a shorted back up lamp switch.
Reply
Old Jul 31, 2006 | 06:18 AM
  #3  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
were your back up lights always on? I'll have to check it out. Any one else have similar problems with different causes?
Reply
Old Aug 2, 2006 | 12:25 AM
  #4  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
anybody else has similar experiences?
Reply
Old Sep 7, 2006 | 05:17 PM
  #5  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
Please bring some light and life back to this thread! Your help would be greatly appreciative in locating the short in the Meter fuse circuit. This is what I've done:

Disconnected ALT, Cooling Fan, H20 thermosensor (wire broke off-damn!), reverse light switch, turbo timer. With all these disconnected, the Meter fuse still blew when the ignition switch is set to ON.

I have also removed the instrument cluster and disconnected all cables on the front side of the fuse box, making some attempt at ohming wires.

This has become quite frustrating and very time consuming. If you've "been there and done that" my attention is all yours. Thanks again in advance for the help!
Reply
Old Sep 8, 2006 | 11:33 AM
  #6  
dhcernese's Avatar
Dan Cernese
Tenured Member 15 Years
 
Joined: Aug 2001
Posts: 208
Likes: 0
From: Pepperell, MA
Fsm?

Originally Posted by Gen2n3
Please bring some light and life back to this thread! Your help would be greatly appreciative in locating the short in the Meter fuse circuit. This is what I've done:

Disconnected ALT, Cooling Fan, H20 thermosensor (wire broke off-damn!), reverse light switch, turbo timer. With all these disconnected, the Meter fuse still blew when the ignition switch is set to ON.

I have also removed the instrument cluster and disconnected all cables on the front side of the fuse box, making some attempt at ohming wires.

This has become quite frustrating and very time consuming. If you've "been there and done that" my attention is all yours. Thanks again in advance for the help!
What about the fan relays? They all go through the same damn fuse. Read the electrical manual that lists all the things connected to the "meter" fuse. I just love it, short a gauge and you can overheat your car :-)
Reply
Old Sep 8, 2006 | 12:49 PM
  #7  
scotty305's Avatar
~17 MPG
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (2)
 
Joined: Jan 2004
Posts: 3,478
Likes: 334
From: Bend, OR
According to page Z-20 of the Wiring Diagram (which can be downloaded from the FSM's sticky here on the forums https://www.rx7club.com/3rd-generation-specific-1993-2002-16/94-fsms-available-download-449950/ ), the Meter fuse protects the following circuits:


Coolant Fan system (low-power relay side, not high-power fan side)
Instrument Cluster & Warning Lights
Transmission Control (if AT)
Rear Wiper & Washer
Turn & Hazard Warning lights
Rear lights (brakes, reverse lights)
Rear window defroster, cigarette lighter,
Power antenna
ECU
Cruise control system



The Meter fuse only has power when the ignition switch is set to ON.


If the water temp & oil pressure gauges went dead first, I would look at those wires, because they're very close to each other. You might have caused problems when you installed the oil pedestal. Those are both sensor lines, they should never be directly connected to ground, ever. When you say the gauges 'went dead', did the lights turn off or did the gauges read 0?

-s-
Reply
Old Sep 8, 2006 | 04:11 PM
  #8  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
By gauges went dead = gauges read 0 (ZERO).

Today's Update:
I removed all fuse box connectors and ohmed out each pin on the fuse box to the Meter Fuse pin. All checks good. I ohmed out each wire from each JB connector to the respective system. All relays were removed and individually ohmed (80 ohms across coils). Contacts are open. Cooling fan motor connectors are also disconnected. There appears to be a short from JB-04 pin I to GND.

Now the question is where is the short located?!!!
Reply
Old Sep 9, 2006 | 08:53 AM
  #9  
dhcernese's Avatar
Dan Cernese
Tenured Member 15 Years
 
Joined: Aug 2001
Posts: 208
Likes: 0
From: Pepperell, MA
wft does "ohmed out" mean?
Reply
Old Sep 9, 2006 | 09:59 AM
  #10  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
an Ohm is a unit of electrical resistance, represented by the greek leter omega; ohming out a circuit is a short way to say taking resistance readings usually with a DMM (digital multimeter) or equivalent.
Reply
Old Sep 9, 2006 | 10:08 AM
  #11  
dhcernese's Avatar
Dan Cernese
Tenured Member 15 Years
 
Joined: Aug 2001
Posts: 208
Likes: 0
From: Pepperell, MA
Originally Posted by Gen2n3
an Ohm is a unit of electrical resistance, represented by the greek leter omega; ohming out a circuit is a short way to say taking resistance readings usually with a DMM (digital multimeter) or equivalent.
I passed all my EE courses with flying colors. I just couldn't quite figure out what the phrase meant. Resistance or continuity or either.. or whatever.
Reply
Old Sep 9, 2006 | 04:37 PM
  #12  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
after visual inspection of the front harness, i haven't been able to locate the short. any probable points for a short?
Reply
Old Sep 9, 2006 | 08:28 PM
  #13  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
any spots to check for a chaffed/melted wire on the front harness? Under the driver wheel well, frame rails by nose and around headlights look clean. Aside from digging thru wiring harness, anyone have a time domain reflectometer to use?
Reply
Old Oct 28, 2006 | 04:40 PM
  #14  
Gen2n3's Avatar
Thread Starter
Super Moderator
Veteran: Navy
Tenured Member: 20 Years
Liked
Community Favorite
iTrader: (1)
 
Joined: Jun 2004
Posts: 2,770
Likes: 400
From: Virginia Beach, VA
yet another update:
disconnected the ECU and relevant connectors under the passenger side firewall. short still exists between fan relays (B/Y) and ground. I even removed and disconnected the heater control assembly & center console panel with same results.

I've never had a short kick my a$$ like this! Anyone care to shed some light? There has to be something I'm overlooking.
Reply
Old Jan 15, 2023 | 02:11 PM
  #15  
JuiceL008's Avatar
Newbie
 
Joined: Jan 2023
Posts: 4
Likes: 0
From: chicago
Switch

Originally Posted by xcelir8
I Had the same problem. I had to tear apart the dash and trace out the wires. It turned out to be a shorted back up lamp switch.
can u send a picture of wat it looks like
Reply
Old Jan 15, 2023 | 02:12 PM
  #16  
JuiceL008's Avatar
Newbie
 
Joined: Jan 2023
Posts: 4
Likes: 0
From: chicago
Update

Originally Posted by Gen2n3
yet another update:
disconnected the ECU and relevant connectors under the passenger side firewall. short still exists between fan relays (B/Y) and ground. I even removed and disconnected the heater control assembly & center console panel with same results.

I've never had a short kick my a$$ like this! Anyone care to shed some light? There has to be something I'm overlooking.
hey, have u gotten any update?
mine is doing the same thing. Some of the harness wires were open so I fixed them but my meter fuse(15) keeps blowing ever time I turn the key.
Reply
Old Jan 16, 2023 | 07:31 AM
  #17  
fendamonky's Avatar
F'n Newbie...
Tenured Member: 15 Years
Liked
Loved
Community Favorite
iTrader: (6)
 
Joined: Sep 2006
Posts: 3,942
Likes: 323
From: Nokesville, Va
Originally Posted by JuiceL008
can u send a picture of wat it looks like
They haven't logged on to the forum since September 2013. Both these threads you bumped are extremely inactive.

You may have better luck by starting a new thread for your unique issue, but linking/referencing these threads to indicate you searched.
Reply
Old Jan 29, 2023 | 03:20 AM
  #18  
rotard7's Avatar
Full Member
iTrader: (6)
 
Joined: Oct 2014
Posts: 108
Likes: 4
From: bay area, CA
Try using a tone generator for wire tracing. You should be able to hook the positive lead(red) to a chassis ground and the other to the fusebox and the wand should transmit a sound when close to the location thet the wire is shorting to ground.

There are aome cheap ones on amazon or some higher end ones at home depot.

Last edited by rotard7; Jan 29, 2023 at 03:31 AM.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
nevertolow
New Member RX-7 Technical
5
Jan 19, 2011 09:37 PM
rjpbboi
2nd Generation Specific (1986-1992)
4
Aug 8, 2008 08:43 PM
EricRyan
3rd Generation Specific (1993-2002)
10
May 9, 2007 11:52 AM
snub disphenoid
1st Generation Specific (1979-1985)
3
Mar 30, 2006 07:29 AM
Mombodogs
2nd Generation Specific (1986-1992)
10
Oct 8, 2005 03:45 PM




All times are GMT -5. The time now is 03:27 PM.