hazard lights on all the time?
#1
hazard lights on all the time?
so i removed the interior from my 1988 turbo II to fix all the rust holes in the floor and was also rebuilding the engine.
i have the dash back in and wiring harness all plugged back in ( except one i cannot find were it goes)
but i connected the battery to see how everything was working and the hazard lights immediately came one. and will not go off.
even if i unplug the switch for the hazard they still stay on. key on or off does not matter. but everything else seems to work correctly.
does anyone have any ideas on this?
i have the dash back in and wiring harness all plugged back in ( except one i cannot find were it goes)
but i connected the battery to see how everything was working and the hazard lights immediately came one. and will not go off.
even if i unplug the switch for the hazard they still stay on. key on or off does not matter. but everything else seems to work correctly.
does anyone have any ideas on this?
#2
Penis Healthy
iTrader: (5)
Join Date: Jul 2013
Location: █▬█ █▄█ █▬█ █▄██▬█ █▄█ █▬█ █▄█
Posts: 2,595
Received 794 Likes
on
452 Posts
so i removed the interior from my 1988 turbo II to fix all the rust holes in the floor and was also rebuilding the engine.
i have the dash back in and wiring harness all plugged back in ( except one i cannot find were it goes)
but i connected the battery to see how everything was working and the hazard lights immediately came one. and will not go off.
even if i unplug the switch for the hazard they still stay on. key on or off does not matter. but everything else seems to work correctly.
does anyone have any ideas on this?
i have the dash back in and wiring harness all plugged back in ( except one i cannot find were it goes)
but i connected the battery to see how everything was working and the hazard lights immediately came one. and will not go off.
even if i unplug the switch for the hazard they still stay on. key on or off does not matter. but everything else seems to work correctly.
does anyone have any ideas on this?
You took the connector that goes at the front of the dash near the windshield and plugged it into your blower box near the passenger footwell under the dash.
You're welcome.
The following users liked this post:
mazdaverx713b (12-10-21)
#3
will look at that today, thanks!
so does that mean i plugged the connector for the blower into the one at the windshield or will that one not reach there?
the one i have not found place for is a smaller connector, i will guess a 6 spade terminal would need to go count it to be sure but it is under the glove box
so does that mean i plugged the connector for the blower into the one at the windshield or will that one not reach there?
the one i have not found place for is a smaller connector, i will guess a 6 spade terminal would need to go count it to be sure but it is under the glove box
#4
YES! that was it. got it plugged into the terminal at the windshield
thanks!
the one plug i cannot find a place for is a 9 pin connector (not a 6 spade, was thinking wrong)
it has
blue w red
white
blue w white
green
green w black
green w red
green
blue w yellow
and i think the last one is a black wire but it is so discolored it is hard to tell
and it is under the glove box and at the end of the dash harness
if anyone has an idea on this one?
thanks!
the one plug i cannot find a place for is a 9 pin connector (not a 6 spade, was thinking wrong)
it has
blue w red
white
blue w white
green
green w black
green w red
green
blue w yellow
and i think the last one is a black wire but it is so discolored it is hard to tell
and it is under the glove box and at the end of the dash harness
if anyone has an idea on this one?
#5
I think i found what that connector is. i think it goes to the powered speaker under the glove box, which i do not have anymore
so only thing now is the logic con does not seem to do anything. it does light up but the blower does not come on and the flapper does not move.
so need to figure that one out.
i did check the fuse box and the circuit breaker looks to be correct. and all my fuses are good
so only thing now is the logic con does not seem to do anything. it does light up but the blower does not come on and the flapper does not move.
so need to figure that one out.
i did check the fuse box and the circuit breaker looks to be correct. and all my fuses are good
#6
Penis Healthy
iTrader: (5)
Join Date: Jul 2013
Location: █▬█ █▄█ █▬█ █▄██▬█ █▄█ █▬█ █▄█
Posts: 2,595
Received 794 Likes
on
452 Posts
I think i found what that connector is. i think it goes to the powered speaker under the glove box, which i do not have anymore
so only thing now is the logic con does not seem to do anything. it does light up but the blower does not come on and the flapper does not move.
so need to figure that one out.
i did check the fuse box and the circuit breaker looks to be correct. and all my fuses are good
so only thing now is the logic con does not seem to do anything. it does light up but the blower does not come on and the flapper does not move.
so need to figure that one out.
i did check the fuse box and the circuit breaker looks to be correct. and all my fuses are good
As for the logicon, I remember mine stopped working at some point. Now I know why. Is there 1 light on?
#7
on the logicon, it lights up as it should. so it appears correct but does not actually do anything
i am leaving for thanksgiving early in the morning so will not get to look at this again till i get back
thanks for your help, i will post a pic of that connector when i am back also
i am leaving for thanksgiving early in the morning so will not get to look at this again till i get back
thanks for your help, i will post a pic of that connector when i am back also
Trending Topics
#8
here it the one plug that i think is for the powered speaker under the golve box
this is the only other thing that i can find that is not plugged in. i think the security box plugs in here but i do not have one
i still can not get the logican to work. like i said it lights up but the blower does not come on and the 2 flaps do not move (cold to hot and the foot/vent/defrost)
also i noticed the fuel guage does not move, i am sure there is fuel in the tank, maybe a half tack. not sure it that is related to the logican
Last edited by rusty FC; 12-08-21 at 11:29 PM.
The following users liked this post:
rlynchster (12-10-21)
Thread
Thread Starter
Forum
Replies
Last Post
ErikTheDead
2nd Generation Specific (1986-1992)
7
09-13-05 10:19 PM