2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

dual FC oil coolers series vs parallel pressure drop results

Thread Tools
 
Search this Thread
 
Old 11-09-07, 06:21 PM
  #1  
slo
registered user

Thread Starter
iTrader: (1)
 
slo's Avatar
 
Join Date: Jan 2006
Location: San Diego
Posts: 2,469
Likes: 0
Received 0 Likes on 0 Posts
dual FC oil coolers series vs parallel pressure drop results

In the last week I finished installing dual FC oil coolers initially in series.

In series I had about a 50 PSI pressure drop at 3k rpm with only 50-60 PSI oil pressure as measured from a known good mechanical oil pressure gauge vs the 110 I am used to seeing using FD oil pressure regulators. At idle oil pressure was 30psi vs the 45 or so I am used to seeing.

The FD pressure spec I have seen quoted from the manual is 50 PSI minimum at 3K rpm.

So I bought the extra 120 dollars worth in fittings (TEE fittings are expensive) to convert the system to parallel and I have actually seen a gain of about 10 PSI under load (vs a single oil cooler) to 120-125 under load and 40-50 at idle.


I wasn't willing to drive hard seing so little pressure so there is no good data regarding oil temps.

your mileage may vary.
Old 11-09-07, 06:49 PM
  #2  
Banned. I got OWNED!!!
 
TitaniumTT's Avatar
 
Join Date: Mar 2006
Location: Connecticut
Posts: 1,970
Likes: 0
Received 1 Like on 1 Post
That makes me a sad panda

So before you converted to dual coolers you had 100PSI @ 3k and it dropped to 50 PSI?
I do have a few questions though
Do you have any pics of the setup?
Which coolers are you using?
Did you change coolers when you went dual or just add another?
Which reg/bypass are you using?

Progress pics from this thread


Old 11-09-07, 07:25 PM
  #3  
slo
registered user

Thread Starter
iTrader: (1)
 
slo's Avatar
 
Join Date: Jan 2006
Location: San Diego
Posts: 2,469
Likes: 0
Received 0 Likes on 0 Posts
I am using stock FC oil coolers

They are all the same

Stock FD oil coolers on models with 2 factory coolers run the system in series and there is no problem with pressure drop.

FD's which use similar aftermaket coolers to yours also generally run in series and have no pressure drop problems.

again I am using stock FD regulators, since you are using a 13b-re (you are right) you will want to get the FD pressure regulators er bypasses like I have done, the RE came stock with 70 PSI units like the FC.

What was happening in my case is there was too much restriction in hitting two coolers and the front bypass was doing what its designed for and limiting the pressure.

I doubt if you will have a problem with your setup using those coolers

oh and nice car.

one more thing, when you go to start tuning your sequential turbo system set it up with the poor mans (very easily reversable) non sequentail. This can actually be done with a couple of check valves in the right places and a few capped un hooked vac lines. Then tune the area abvove 4k rpm, before going back to sequential to tune below 4k rpm and the transistion. You don't want to have to worry about troubleshooting the turbo's and tuning at the same time.

Last edited by slo; 11-09-07 at 07:32 PM.
Old 11-09-07, 07:28 PM
  #4  
Banned. I got OWNED!!!
 
phoenix7's Avatar
 
Join Date: Dec 2006
Posts: 26
Likes: 0
Received 1 Like on 1 Post
PM Higgi. We were talking about the dual oil cooler a while back but can't remember all the details but I don't think he's seeing the pressure drops you see and his temps have decreased dramatically.
Old 11-09-07, 07:31 PM
  #5  
slo
registered user

Thread Starter
iTrader: (1)
 
slo's Avatar
 
Join Date: Jan 2006
Location: San Diego
Posts: 2,469
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by phoenix7
PM Higgi. We were talking about the dual oil cooler a while back but can't remember all the details but I don't think he's seeing the pressure drops you see and his temps have decreased dramatically.
If he's not using stock FC oil coolers then this really doesn't apply to him.

I suppose its possible that my front bypass could be weak.
Old 11-09-07, 07:44 PM
  #6  
Banned. I got OWNED!!!
 
phoenix7's Avatar
 
Join Date: Dec 2006
Posts: 26
Likes: 0
Received 1 Like on 1 Post
he's using 2 stock ICs. Why would I tell you to go ask someone if it didn't apply?
Old 11-09-07, 07:54 PM
  #7  
Banned. I got OWNED!!!
 
TitaniumTT's Avatar
 
Join Date: Mar 2006
Location: Connecticut
Posts: 1,970
Likes: 0
Received 1 Like on 1 Post
Originally Posted by slo
I am using stock FC oil coolers
They are all the same
Phew - that's what I was hoping for.

Originally Posted by slo
Stock FD oil coolers on models with 2 factory coolers run the system in series and there is no problem with pressure drop.
FD's which use similar aftermaket coolers to yours also generally run in series and have no pressure drop problems.
again I am using stock FD regulators, since you are using a 13b-re (you are right) you will want to get the FD pressure regulators er bypasses like I have done, the RE came stock with 70 PSI units like the FC.
Which is one of the reasons I decided to go with the series instead of the parrellel. I did conjur that system up with the thought that I MAY need to go Par - so I positioned the coolers so that I could just add two tee fittins on the back side of the T-Stat and convert those 2 90*'s to 4 straits and be done. HOPEFULLY that won't be the care.
Yes the RE has the FC regs and you are right - going all FD regs & bypass spring.

Originally Posted by slo
What was happening in my case is there was too much restriction in hitting two coolers and the front bypass was doing what its designed for and limiting the pressure.

I doubt if you will have a problem with your setup using those coolers

oh and nice car.
I hope not - and thank you

Originally Posted by slo
one more thing, when you go to start tuning your sequential turbo system set it up with the poor mans (very easily reversable) non sequentail. This can actually be done with a couple of check valves in the right places and a few capped un hooked vac lines. Then tune the area abvove 4k rpm, before going back to sequential to tune below 4k rpm and the transistion. You don't want to have to worry about troubleshooting the turbo's and tuning at the same time.
That is actually a REALLY good suggestion.... damn .... thanks I MAY try to do the non-sequential as is becuase I can just set the actuators to full open/closed as they would need to be so that the vac chamber would be pulling the turbo control and if that wasn't enough as soon as there was a little boost it would go non-sequential. I'd have to play a little but that a DAMN good idea. Speaking of the tuning - here a linky to some pics of the Motec and the harness

http://forum.teamfc3s.org/showthread.php?t=54990&page=5
Old 11-10-07, 02:08 AM
  #8  
Tall, Dark, & Handsome

iTrader: (19)
 
Angry Earl's Avatar
 
Join Date: Feb 2007
Location: WA State
Posts: 641
Likes: 0
Received 9 Likes on 4 Posts
THIS is very interesting...I've been thinking of doing something like this for a while now...



Can you please post pics?



Have you ever tried doing a v-mount oil cooler setup (dual stock FC oil coolers stock position in front of the radiator, in a 90*V-angle setup)?



Does this make sense/would work good, or is it retarded?
Old 11-10-07, 02:26 AM
  #9  
Banned. I got OWNED!!!
 
phoenix7's Avatar
 
Join Date: Dec 2006
Posts: 26
Likes: 0
Received 1 Like on 1 Post
The way that makes sense comes from the 80's competition manual

The oil cooler was mounted on the Underbelly tray, parallel to the ground (with the underbelly tray cut to the size of oil cooler so hot air goes under the car in a vaccuum effect) with a duct that comes from the lower part of the front opening to the back of the oil cooler. This allowed the radiator and oil cooler to get their own, unadulterated, ambient air supply (which will be cooler than the temps of a high revving, nice HP race car in the middle of a race).

I have to look but I have the schematics somewhere.

I'll look into the Mazda Comp oil cooler and if it's still available too.
Old 11-10-07, 04:25 AM
  #10  
Junior Member

 
FC3S~'s Avatar
 
Join Date: May 2006
Location: Perth, Australia
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
looks mean with that oil cooler
Old 11-11-07, 04:31 AM
  #11  
Moderator

iTrader: (7)
 
hIGGI's Avatar
 
Join Date: Feb 2001
Location: Czech Republic [www.rx7cz.net]
Posts: 4,985
Received 17 Likes on 12 Posts
i run 2 stock FC oil coolers in series, mazdatrix (or RB?) 75-80psi regulator and good oil pump and my oil pressure on warmed up oil is 5 bar over 2000 rpm and higher....

cold oil its 6 bar, lowest pressure at idle - 2 bar..

both coolers have thermostats in them, working...

oil pressure measured under oil filter with trustable aftermarket gauge (apexi)
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
FD7KiD
3rd Generation Specific (1993-2002)
15
02-26-21 10:12 PM



Quick Reply: dual FC oil coolers series vs parallel pressure drop results



All times are GMT -5. The time now is 10:37 PM.