Pulsation Damper Prototype

Old Apr 11, 2004 | 10:35 PM
  #1  
neptuneRX's Avatar
Thread Starter
Mazda4Life
Tenured Member 05 Years
 
Joined: Aug 2003
Posts: 1,228
Likes: 0
From: Rockville, MD
Pulsation Damper Prototype

Ok, here's a little draw up of what I've been cooking at. Need some feed back though. If anyone has questions comments please let me know, this isn't just 7 related, but I'm doing it because as far as I know, the RX7 has the most difficulties with this. Please have as many people as you can contact take a look at this, if you can find any flaws in the design please let me know. I'm gonna have a machine shop make of these babies at the end of next month. but I want it to be as close to perfect as possible.
Reply
Old Apr 12, 2004 | 09:21 AM
  #2  
neptuneRX's Avatar
Thread Starter
Mazda4Life
Tenured Member 05 Years
 
Joined: Aug 2003
Posts: 1,228
Likes: 0
From: Rockville, MD
oh come on, someone has to have a bloody comment!
Reply
Old Apr 12, 2004 | 09:50 AM
  #3  
neptuneRX's Avatar
Thread Starter
Mazda4Life
Tenured Member 05 Years
 
Joined: Aug 2003
Posts: 1,228
Likes: 0
From: Rockville, MD
DAMN IT PEOPLE SAY SOMETHING!!!
Reply
Old Apr 12, 2004 | 09:58 AM
  #4  
tmiked's Avatar
Waiting for the RX-9
Tenured Member 10 Years
 
Joined: Mar 2003
Posts: 957
Likes: 0
From: Texas
SUX
Reply
Old Apr 12, 2004 | 12:04 PM
  #5  
nevarmore's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 739
Likes: 0
From: NE Ohio
What does the pulsation damper do? I'm a bit of an armchair engineer, if I knew that I could make an educated guess.
Reply
Old Apr 12, 2004 | 12:44 PM
  #6  
Red 86 rx-7's Avatar
wet drifting dream
Tenured Member 05 Years
 
Joined: Sep 2003
Posts: 161
Likes: 0
From: Earth
I think it's a good Idea the PD in my car failed and almost cost me the whole car!
Reply
Old Apr 12, 2004 | 01:38 PM
  #7  
SnowmanSteiner's Avatar
Ga-nome liberator
Tenured Member: 20 Years
 
Joined: Jul 2002
Posts: 1,990
Likes: 0
From: Hell
The PD reduces the pulsations often accomponied by the fuel pump. This helps so that you don't get random spurts of fuel being sent to the injectors, and then having a lapse of fuel. The pulsation dampner evens this out so the injectors get a constant steady flow, provided that the fuel pump continues. The problem with stock pd's is there is a screw inside that often comes loose and fuel can leak out, if the fuel reaches the exhaust manifold it can ignite and set your engine bay on fire. I'm not sure if I can fully understand and comprehend your design. Maybe if you made it more descriptive and if you labeled everything better that would help.

- Steiner
Reply
Old Apr 12, 2004 | 05:07 PM
  #8  
Dcrasta's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Sep 2002
Posts: 408
Likes: 0
From: WDC
I think its moot. The FB SE has 2 pulsation dampers, and the one on the rail is the one that causes the fires. Just throw it away and get a 12x1.25 banjo bolt and throw it in. The damper on the fuel pump works fine. Your design looks like it would cause restrictions, and doesnt seem to have a 'diaphram' or spring that would help dampen then pulsations..
Reply
Old Apr 12, 2004 | 05:48 PM
  #9  
black_sunshine's Avatar
Full Member
Tenured Member 20 Years
 
Joined: Nov 2001
Posts: 206
Likes: 0
From: Springfield, MO
Why does everyone seem to think that the screw falling out has something to do with it (PD) leaking? It has absolutely nothing to do with it. If you've ever removed the plastic cap over the PD, and rev your engine up, you'll notice that as fuel pressure increases, the screw is pushed out with the diaphragm.


ANYHOW, the best (and more simplistic) design would be a plunger with a spring behind it. Just like the stock diaphragm mechanism, sans diaphragm and pre-tentioner screw, but with a neoprene plunger that won't rot, and a spring.

OR you could just ditch the whole setup and replace it with a banjo bolt since the FPR also has a dampening effect.
Reply
Old Apr 12, 2004 | 06:55 PM
  #10  
nevarmore's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 739
Likes: 0
From: NE Ohio
Would it be easier to remove the pulsation dampner and use a unit that is not mounted to the intake plenum?

Whaddabout a better fuel pump that provides a steadier flow of fuel. The PD is a response to a fuel flow problem, instead of fixing a suboptimal solution, fix the initial problem.
Reply
Old Apr 12, 2004 | 08:08 PM
  #11  
SnowmanSteiner's Avatar
Ga-nome liberator
Tenured Member: 20 Years
 
Joined: Jul 2002
Posts: 1,990
Likes: 0
From: Hell
The pressure from any fuel pump is going to have variations in it.

- Steiner
Reply
Old Apr 14, 2004 | 12:04 PM
  #12  
Dcrasta's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Sep 2002
Posts: 408
Likes: 0
From: WDC
Wow this topic lived longer than I thought. I just think everyone is on the right track but different fixes. I know Im scraping the PD and the stock fuel pump and going with upgrades. U can put a nice FPR on the return line. Most FPR's also dampen the fuel flow (or act as a damper), and with a return style fuel system like ours, Im not really sure fuel pulsation is a big problem as long as the fuel pump can keep up and the fpr is working correctly.
Reply
Old Apr 18, 2004 | 11:50 AM
  #13  
neptuneRX's Avatar
Thread Starter
Mazda4Life
Tenured Member 05 Years
 
Joined: Aug 2003
Posts: 1,228
Likes: 0
From: Rockville, MD
thanks for the good inpunt, I'm gonna work on it some more.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
ls1swap
3rd Generation Specific (1993-2002)
17
Jun 3, 2024 03:25 PM
FC_DREAMS
General Rotary Tech Support
20
Sep 22, 2015 09:43 PM
MODRIFT7
Old School and Other Rotary
1
Sep 22, 2015 12:14 PM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 12:39 AM.