General Rotary Tech Support Use this forum for tech questions not specific to a certain model year
Sponsored by:
Sponsored by: CARiD

Leaking Pulsation Damper

Thread Tools
 
Search this Thread
 
Old Jan 21, 2004 | 03:28 AM
  #1  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
Leaking Pulsation Damper

I was working on my car, me and my buddies, and we noticed that there was this leak from the main fuel rail and as I suspected this was from the Pulsation Damper. I took it of and the first thing I did was to take off the plastic cup off of it, there was loose little screw in there and it was obvious that it was leaking from the hole where that screw was supposed to go in to. I screwed it in and put some RTV over it, just to make sure it does not unscrew/leak again. My question is, how hard should it be screwed in? and, Is there anything else that I should know before driving around like this?



P.S. I will definitely check for the leak and if so I will not drive the car, all your info would be appreciated. If you don’t know/remember what it looks like here is a link to mazdatrix.com . http://www.mazdatrix.com/c-pulsation.htm

P.S.S. I would also like to know what that little screw does for the pulsation damper.

sorry about the double post, but i figured that maybe someone in tech support might know an answer for this question better and I'm in need of an answer bad.


Car is a 1987 TII S4, built on 03/86, is just now having a RB exhaust put on with FCD, ported waste gate, < dont think that makes a difference but there is my car for ref.
Reply
Old Jan 21, 2004 | 04:56 AM
  #2  
black_sunshine's Avatar
Full Member
Tenured Member 20 Years
 
Joined: Nov 2001
Posts: 206
Likes: 0
From: Springfield, MO
The screw is a pretensioner that adjusts the ammount of dampening the damper does (adjusts the ammount of "backpressure" if you will). If it's leaking, that's not due to the missing screw, but is due to the ruptured diaphragm inside the pulsation damper. REPLACE IT ASAP or be prepared for a helluva fire (it WILL happen).

My reccomendation is to replace the PD with a banjo bolt and barb (usually one from a spare rail) and use that instead. That way, it never leaks. I've done this to every car I've owned with no noticable effects.
Reply
Old Jan 22, 2004 | 10:57 PM
  #3  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
Is there a preformance loss?
Reply
Old Jan 23, 2004 | 01:34 AM
  #4  
black_sunshine's Avatar
Full Member
Tenured Member 20 Years
 
Joined: Nov 2001
Posts: 206
Likes: 0
From: Springfield, MO
Not at all that I've noticed; I've no dyno info to prove it, although my butt dyno tells me there is no difference.

The only negative I've heard of is that it supposedly makes the fuel pump and or injectors' life harder. I vouch to disprove this, due to the FPR having a damping effect (at idle anyways). I've been running without a PD for 3 years now, and I have not noticed any degredation of the fuel-related components.

Also, I forgot to mention in my previous post, that as fuel pressures rise, the PD's diaphragm moves outward and pushes the screw out with it.
Reply
Old Jan 23, 2004 | 01:07 PM
  #5  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
http://fc3spro.com/TECH/FAQ/pd.html
Will this work/fit? Will I have to do any modifications to the fuel rails or anything? or is it a bolt on?

P.S. Thanks for all your help
Reply
Old Jan 23, 2004 | 10:57 PM
  #6  
black_sunshine's Avatar
Full Member
Tenured Member 20 Years
 
Joined: Nov 2001
Posts: 206
Likes: 0
From: Springfield, MO
It's (quite litterally) a bolt-on mod. Just a superiorly machined/anodized version of what I was suggesting For some reason, I completely forgot that Summit offered these (doh!).
Reply
Old Jan 23, 2004 | 11:45 PM
  #7  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
the ones that summit offers, do they fit right on, as in bolt on?
Reply
Old Jan 24, 2004 | 04:53 AM
  #8  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
bump
Reply
Old Jan 24, 2004 | 09:29 PM
  #9  
-=Lil Red=-'s Avatar
R.I.P. Guitarjunkie28
Tenured Member 15 Years
iTrader: (24)
 
Joined: Nov 2003
Posts: 4,370
Likes: 4
From: 626 So Cal
awsome, i need to upgrad to this too, better this and not a fire later!

thanks for the find
Reply
Old Jan 25, 2004 | 03:13 PM
  #10  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
I just emailed fc3 web site and the guy said that all you need is the bonjo bolt and a couple of washers from mazda dealership, sweet, thx alot
Reply
Old Jan 28, 2004 | 06:27 PM
  #11  
-=Lil Red=-'s Avatar
R.I.P. Guitarjunkie28
Tenured Member 15 Years
iTrader: (24)
 
Joined: Nov 2003
Posts: 4,370
Likes: 4
From: 626 So Cal
do i need to remove the whole manifold???

i have tried and not sure wat to do to take off this damn pulsation damper, please reply ASAP.

THANX
Reply
Old Jan 28, 2004 | 09:11 PM
  #12  
-=Lil Red=-'s Avatar
R.I.P. Guitarjunkie28
Tenured Member 15 Years
iTrader: (24)
 
Joined: Nov 2003
Posts: 4,370
Likes: 4
From: 626 So Cal
hey guys, i tried going to autozone, pep boys, kragen, and king bolt. i did not find 12mm x 1.25 banjo bolt. i tried at the dealer but they need to know where it goes they said they dont carry banjo bolts .

they have 12 x 1.0 and 12 x 1.5

where can i get the right size? and also how the hell does the pulsation damper come off??? i cannot take it off. any picture step by step that someone has written somewhere?

thanx in advance
Reply
Old Jan 28, 2004 | 11:24 PM
  #13  
-=Lil Red=-'s Avatar
R.I.P. Guitarjunkie28
Tenured Member 15 Years
iTrader: (24)
 
Joined: Nov 2003
Posts: 4,370
Likes: 4
From: 626 So Cal
ok, i took off the PD after i took off the whole manifold with a friend.

i was wondering can i just use a regular bolt? i found a regular 12 x 1.25 bolt at an autoparts store but it is not a banjo bolt. can this be used instead? or does it have to be a BANJO bolt?

because a banjo bolt has a hole thought it for fluid to go through it, in this case fuel.
Reply
Old Jan 31, 2004 | 02:34 PM
  #14  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
You must have a banjo bolt other wise there will be no pressure. I have been tempted to just drill a hole in the middle of a bolt that fits and then drill another small one that goes accoss through it, but I think I'll just stay with the one from fc3 website or wait no its accually summit racing and here are the links, (it ridiculas that for a freaking bolt you have to pay 8.95 hadling fee) http://fc3spro.com/TECH/FAQ/pd.html <--------- thats the link to the place that will have a link to summit racing which is http://www.summitracing.com/ and then input this part number EAR-997591 and here is more info from another thread https://www.rx7club.com/showthread.p...threadid=60160
Reply
Old Jan 31, 2004 | 02:47 PM
  #15  
Sergei The Saint's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Oct 2002
Posts: 155
Likes: 0
From: Utah
just ordered mine
Reply
Old Jan 31, 2004 | 05:42 PM
  #16  
-=Lil Red=-'s Avatar
R.I.P. Guitarjunkie28
Tenured Member 15 Years
iTrader: (24)
 
Joined: Nov 2003
Posts: 4,370
Likes: 4
From: 626 So Cal
thanx for the info, but i went the cheaper way, found a banjo bolt from an extra fuel rail so i will be using that instead, hehe. i am tired of looking everywhere for that damn bolt, and i didint want to pay summit like $20 just for a bolt, hehe.

good stuff thogh, thanx for all the help
Reply
Old Feb 24, 2004 | 12:10 PM
  #17  
Junior Member
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 6
Likes: 0
From: el paso, tx
Originally posted by black_sunshine
Not at all that I've noticed; I've no dyno info to prove it, although my butt dyno tells me there is no difference.

The only negative I've heard of is that it supposedly makes the fuel pump and or injectors' life harder. I vouch to disprove this, due to the FPR having a damping effect (at idle anyways). I've been running without a PD for 3 years now, and I have not noticed any degredation of the fuel-related components.

Also, I forgot to mention in my previous post, that as fuel pressures rise, the PD's diaphragm moves outward and pushes the screw out with it.
hey blacksunshine, i have couple questions - since you seem to be the expert. i have a 3rd gen rx-7 and it seems to have all the same signs that i have been reading on pulsation damper leaks. when i drive around - i smell gas, when i check my engine, its moist on the top. i havent driven it in a while until i fix this problem (and replace my turbos). but i guess my question is - is that whats wrong? also, i might be replacing my turbos (with the stock twin setup) where can i get all the gaskets im gonna need (cheap)? hey thanks guys
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
ls1swap
3rd Generation Specific (1993-2002)
17
Jun 3, 2024 03:25 PM
Turblown
Vendor Classifieds
12
Oct 17, 2020 03:25 PM
LongDuck
1st Generation Specific (1979-1985)
12
Oct 7, 2015 08:12 PM
James Knox
New Member RX-7 Technical
9
Oct 5, 2015 07:56 AM




All times are GMT -5. The time now is 07:11 AM.