3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

how to check if you put the primary fuel rain in correctly

Old May 7, 2004 | 02:31 AM
  #1  
skunks's Avatar
Thread Starter
I'm a CF and poop smith
Tenured Member 10 Years
 
Joined: Aug 2001
Posts: 3,957
Likes: 1
From: Hawaii
how to check if you put the primary fuel rain in correctly

how do you check if you put the primary fuel rain in correctly. would putting it in incorrectly not allow the engine to start? i know there would be a huge airleak but it should still start or attempt to start right?

in anycase, i recently replaced the fpd and i cant seem to get my car started. the starter is spinning very fast and started to sputter but then it just stopped and it the engine just spins and spins wiht the starter only. i can hear the compression strokes from the exhuast and they seem even (car was running nicely before i took it apart so i doubt it popped in the 3 weeks where it was apart). im gonna check fuel and spark tomorrow, ran out of sunlight and energy today.
Reply
Old May 7, 2004 | 10:27 AM
  #2  
rex u.k's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Jun 2003
Posts: 322
Likes: 0
From: England,u.k
I don't think you can put it in wrong, it will only fit one way.Just make sure you put the plastic spacer back in that goes between the rail and the housing.
Reply
Old May 7, 2004 | 10:32 AM
  #3  
FormerPorscheGuy's Avatar
Yes it is for sale.
Tenured Member 15 Years
 
Joined: Aug 2002
Posts: 1,905
Likes: 1
From: The Houston Club's Resident Lush.
Was the rail tight when you put it back in? The fuel rail sits on those two rubber grommets and the plastic spacer under the bolts. When you have it bolted in it should not move around. Did you preasurize your fuel system and check for leaks around the fuel rail? Did it hold fuel preasure over night?

When I did my primary fuel rail some how I ended up with a flooded engine after reassembly. I had to go through the unflooding procedure and it started fine.
Reply
Old May 7, 2004 | 11:25 AM
  #4  
zUMIEz's Avatar
Full Member
Tenured Member 15 Years
iTrader: (2)
 
Joined: Mar 2004
Posts: 94
Likes: 0
From: Edmonton, Canada
You may want to check your electrical hook-ups as you reassembled things, including whether you have the injectors plugged in right.
Reply
Old May 18, 2004 | 10:49 PM
  #5  
chris_stampe's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Nov 2001
Posts: 725
Likes: 0
From: Spearfish, SD
What is this plastic spacer that goes between the rail and the housing? Ive never had/seen one. Can I just use washers...but it fits w/out a spacer and didnt used to leak.
Reply
Old May 18, 2004 | 11:06 PM
  #6  
skunks's Avatar
Thread Starter
I'm a CF and poop smith
Tenured Member 10 Years
 
Joined: Aug 2001
Posts: 3,957
Likes: 1
From: Hawaii
thats weird, it should have some kinda washer to seal it up. in anycase, i think mines is on correctly now.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
trickster
2nd Generation Specific (1986-1992)
25
Jul 1, 2023 04:40 PM
cristoDathird
Introduce yourself
28
May 30, 2019 08:47 PM
82streetracer
Haltech Forum
11
Mar 11, 2019 05:34 PM
Jmolina0163
1st Generation Specific (1979-1985)
10
Oct 3, 2015 10:04 AM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 07:46 AM.