how to check if you put the primary fuel rain in correctly
#1
I'm a CF and poop smith
Thread Starter
how to check if you put the primary fuel rain in correctly
how do you check if you put the primary fuel rain in correctly. would putting it in incorrectly not allow the engine to start? i know there would be a huge airleak but it should still start or attempt to start right?
in anycase, i recently replaced the fpd and i cant seem to get my car started. the starter is spinning very fast and started to sputter but then it just stopped and it the engine just spins and spins wiht the starter only. i can hear the compression strokes from the exhuast and they seem even (car was running nicely before i took it apart so i doubt it popped in the 3 weeks where it was apart). im gonna check fuel and spark tomorrow, ran out of sunlight and energy today.
in anycase, i recently replaced the fpd and i cant seem to get my car started. the starter is spinning very fast and started to sputter but then it just stopped and it the engine just spins and spins wiht the starter only. i can hear the compression strokes from the exhuast and they seem even (car was running nicely before i took it apart so i doubt it popped in the 3 weeks where it was apart). im gonna check fuel and spark tomorrow, ran out of sunlight and energy today.
#3
Yes it is for sale.
Join Date: Aug 2002
Location: The Houston Club's Resident Lush.
Posts: 1,905
Likes: 0
Received 1 Like
on
1 Post
Was the rail tight when you put it back in? The fuel rail sits on those two rubber grommets and the plastic spacer under the bolts. When you have it bolted in it should not move around. Did you preasurize your fuel system and check for leaks around the fuel rail? Did it hold fuel preasure over night?
When I did my primary fuel rail some how I ended up with a flooded engine after reassembly. I had to go through the unflooding procedure and it started fine.
When I did my primary fuel rail some how I ended up with a flooded engine after reassembly. I had to go through the unflooding procedure and it started fine.
#5
Senior Member
Join Date: Nov 2001
Location: Spearfish, SD
Posts: 725
Likes: 0
Received 0 Likes
on
0 Posts
What is this plastic spacer that goes between the rail and the housing? Ive never had/seen one. Can I just use washers...but it fits w/out a spacer and didnt used to leak.