3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Which fuel pump to use?

Thread Tools
 
Search this Thread
 
Old Aug 24, 2006 | 04:48 PM
  #1  
HAYWIRE93's Avatar
Thread Starter
Full Member
Tenured Member 05 Years
 
Joined: Aug 2006
Posts: 113
Likes: 0
From: Washington
Which fuel pump to use?

I am looking for a drop in fuel pump that can support around 350RWHP, what kind is most used?
Reply
Old Aug 24, 2006 | 05:47 PM
  #2  
HAYWIRE93's Avatar
Thread Starter
Full Member
Tenured Member 05 Years
 
Joined: Aug 2006
Posts: 113
Likes: 0
From: Washington
Anyone?
Reply
Old Aug 24, 2006 | 05:50 PM
  #3  
rizzxx7's Avatar
DIGG7ER
Tenured Member 20 Years
iTrader: (4)
 
Joined: Apr 2001
Posts: 988
Likes: 0
From: virginia beach, va.
get a supra pump, its a direct drop in or you can go with a walbro and save about 125 dollars.
Reply
Old Aug 24, 2006 | 05:52 PM
  #4  
slopoke03's Avatar
Junior Member
Tenured Member 05 Years
 
Joined: Jul 2005
Posts: 42
Likes: 0
From: California
supra pump will be fine. if you expect your power needs to go up, consider getting the skyline pump or apexi's version (BNR33)
Reply
Old Aug 24, 2006 | 05:59 PM
  #5  
HDP's Avatar
HDP
A Fistfull of Dollars!
Tenured Member: 20 Years
iTrader: (2)
 
Joined: Nov 2002
Posts: 5,322
Likes: 6
From: HuntsVEGAS, AL
Walbro. Why spend several hundred dollars on a Supra pump when you can get a Walbro for about $100 and it will be more than enough for the numbers you're shooting for.
Reply
Old Aug 24, 2006 | 06:23 PM
  #6  
EZFD's Avatar
Senior Member
Tenured Member 15 Years
 
Joined: Jul 2005
Posts: 520
Likes: 0
From: Lancaster, NY
Supra pump
Reply
Old Aug 24, 2006 | 09:45 PM
  #7  
Rotary Enthusiast
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 1,083
Likes: 4
From: california
rx7.com pump with extra ground wires. just ask chris
Reply
Old Aug 24, 2006 | 09:57 PM
  #8  
twokrx7's Avatar
Need more sleep
Tenured Member 15 Years
iTrader: (1)
 
Joined: Nov 2001
Posts: 1,690
Likes: 3
From: Woodlands TX
rewired stock pump will do just fine
Reply
Old Aug 25, 2006 | 12:33 PM
  #9  
nicad2's Avatar
HC is too high
Tenured Member 15 Years
iTrader: (3)
 
Joined: Nov 2005
Posts: 189
Likes: 4
From: USA
How about just replace your stock fuel pump wiring to guarantee 13.5V and you will get 350rwhp.

Assuming
15psi boost
15psi pressure drop in your stock fuel lines
40psi injector pressure (conservative, since it should be closer to 36psi)

350rwhp requires 161Liters/Hour @ 70psi.
http://www.maxcooper.com/rx7/how-to/...tem/calcs.html

Attached test data from:
http://www.stealth316.com/2-fuelpumpguide.htm




Oh Jees, I took to long to finish this post.
Originally Posted by twokrx7
rewired stock pump will do just fine
Attached Thumbnails Which fuel pump to use?-flowtest-denso.gif  
Reply
Old Aug 25, 2006 | 02:14 PM
  #10  
HAYWIRE93's Avatar
Thread Starter
Full Member
Tenured Member 05 Years
 
Joined: Aug 2006
Posts: 113
Likes: 0
From: Washington
Thanks very much for the info.Rewiring the stock pump souns like a good idea.What is the easiest method?
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
trickster
2nd Generation Specific (1986-1992)
25
Jul 1, 2023 04:40 PM
Rotospectre
New Member RX-7 Technical
3
Mar 28, 2018 03:33 PM
ChrisRX8PR
Single Turbo RX-7's
21
Oct 18, 2015 04:01 PM




All times are GMT -5. The time now is 09:30 AM.