3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

BNR fuel thread

Thread Tools
 
Search this Thread
 
Old 09-03-11, 09:11 PM
  #1  
rotary sensei

Thread Starter
iTrader: (5)
 
Mr rx-7 tt's Avatar
 
Join Date: Mar 2001
Location: Virginia
Posts: 2,312
Likes: 0
Received 0 Likes on 0 Posts
BNR fuel thread

I'm working on a car and I have BNR's on the way. The car currently has two stock 550's in the primary rails, two 1300's in the secondary rail and a Supra pump. I've seen where some have made ~425 rwhp and I should have plenty of fuel with the current srt up.

http://www.maxcooper.com/rx7/how-to/...tem/calcs.html

Now I have also seen where others have said where they were short on fuel with this set up but even with 1680's in the secondaries? Thought by those who have used the BNR's??? Is there something weird about these as far as fuel???

Maybe uping the fuel pressure with an Aeromotive pump...
http://realstreetperformance.com/sto...on-test-5.html
Old 09-03-11, 09:23 PM
  #2  
Original Gangster/Rotary!


iTrader: (213)
 
GoodfellaFD3S's Avatar
 
Join Date: Mar 2001
Location: FL-->NJ/NYC again!
Posts: 30,529
Received 539 Likes on 326 Posts
I made 421 on a dynapack at 17 psi non-seq, with 850/1300 and a Supra pump. IIRC the pump was running out of steam so extra fuel inj duty cycle was dialed to compensate. I was in the 90% + range.

If you search my username and 'BNR dyno' you'll find a bunch of my old threads with my setup
Old 09-03-11, 09:33 PM
  #3  
rotary sensei

Thread Starter
iTrader: (5)
 
Mr rx-7 tt's Avatar
 
Join Date: Mar 2001
Location: Virginia
Posts: 2,312
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by GoodfellaFD3S
I made 421 on a dynapack at 17 psi non-seq, with 850/1300 and a Supra pump. IIRC the pump was running out of steam so extra fuel inj duty cycle was dialed to compensate. I was in the 90% + range.

If you search my username and 'BNR dyno' you'll find a bunch of my old threads with my setup
So if I toss out the Supra pump and use the Aeromotive do you think I'll have enough fuel?
Old 09-03-11, 09:36 PM
  #4  
Original Gangster/Rotary!


iTrader: (213)
 
GoodfellaFD3S's Avatar
 
Join Date: Mar 2001
Location: FL-->NJ/NYC again!
Posts: 30,529
Received 539 Likes on 326 Posts
If your goals are 400+ I'd say you'll need 850/1300s. You can try 550/1300 but I doubt you can max BNRs with them. Hotwiring the supra pump is another option, or moving up to a higher-flowing pump.

This thread has some good info:

https://www.rx7club.com/3rd-gen-archives-73/some-fuel-system-ramblings-578521/
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
cristoDathird
Introduce yourself
28
05-30-19 08:47 PM
bb6guy
Old School and Other Rotary
10
10-01-18 08:07 AM
BNR34RB26DETT
Build Threads
42
02-28-18 11:27 AM
sYnth.
Build Threads
0
08-19-15 06:27 PM
bb6guy
3rd Generation Specific (1993-2002)
3
08-12-15 03:29 PM



Quick Reply: BNR fuel thread



All times are GMT -5. The time now is 01:53 PM.