The Big Fat FD3S Cooling Thread

Old Jan 28, 2012 | 06:56 AM
  #151  
Adam R.'s Avatar
Junior Member
Tenured Member 05 Years
 
Joined: Nov 2009
Posts: 40
Likes: 0
From: Poland
what electric water pump flow rate we need ?
80l/m or 115l/m ?
Reply
Old Jan 28, 2012 | 10:55 AM
  #152  
s1mpsons's Avatar
HamfistRacing.com
Tenured Member 20 Years
iTrader: (5)
 
Joined: Jan 2003
Posts: 1,197
Likes: 4
From: NYC
I suspect when autoxing, sustained (top of 2nd gear) high revs causes water pump cavitation dramatically increasing temps all around. My assumption is that revving 7000-9200rpm (an in some cases pinning the limiter for 1/2 to a 1 full second in 2nd gear), is creating lots of cavitation and not allowing the coolant to flow when it is needed most. To lower temps more, I am considering under-driving the water pump pulley (or perhaps the main shaft pulley). Which do you all think would be more effective? It makes most sense to under-drive the water-pump since it is the obvious culprit. but it is likely the power-steering is being over-driven as well.

What pulleys specifically will address my goal.

I've heard of the RE-medy Water Pump upgrade with superior anti-cavitation impeller. The unit seems to be out of stock and also is rumored to fail. So that is off the table.

Also, please refrain from making comments on shift points or gearing.
Reply
Old Jan 28, 2012 | 01:39 PM
  #153  
jkstill's Avatar
Searching for 10th's
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (11)
 
Joined: May 2002
Posts: 2,275
Likes: 42
From: Portland OR
Originally Posted by s1mpsons
I've heard of the RE-medy Water Pump upgrade with superior anti-cavitation impeller. The unit seems to be out of stock and also is rumored to fail. So that is off the table.

Also, please refrain from making comments on shift points or gearing.
I have the RE-medy pump for just the reasons you stated.

My FD is pretty much autox only. The diff gears are 4.77, so the revs stay consistently high.

On a 96f day the water temps never exceeded 215f, and oil didn't exceed 210f.

As for the RE-medy pumps failing, I have had no issues with mine in 3 seasons of autox.

I do know someone else that has had his RE-medy pump leak, replaced it, and now the third one is leaking.

We both have single turbo cars. The difference - there is an idler pulley on my car for the belt to the water pump, and his does not have one.

We think that over-tightening of the belt is the culprit in this case.
Reply
Old Jan 28, 2012 | 02:13 PM
  #154  
Rx7_Nut13B's Avatar
Red Neck Tony Stark - C2
Tenured Member 15 Years
iTrader: (1)
 
Joined: Aug 2002
Posts: 2,828
Likes: 1
From: Houston Tx
Originally Posted by Adam R.
what electric water pump flow rate we need ?
80l/m or 115l/m ?
55g per min

115l per min is about 30g per min. On a rotary I don't think that is enuff.
Reply
Old Jan 28, 2012 | 02:31 PM
  #155  
s1mpsons's Avatar
HamfistRacing.com
Tenured Member 20 Years
iTrader: (5)
 
Joined: Jan 2003
Posts: 1,197
Likes: 4
From: NYC
The RE-Medy ould be a good option if they were in stock and available (I have the idler pulley)...

Also, I suppose an electric pump might be a nice option. Is there a source to order eveything needed to switch to electric? If I went electric I could remove the tweakit idler pulley and save weight. It'll also free up load on the drive pulley and power.

Are the electric pumps heavier than the pulley style water pumps?
Reply
Old Jan 29, 2012 | 03:03 AM
  #156  
Adam R.'s Avatar
Junior Member
Tenured Member 05 Years
 
Joined: Nov 2009
Posts: 40
Likes: 0
From: Poland
electric EWP about 900 grams
Reply
Old Jan 29, 2012 | 08:10 AM
  #157  
s1mpsons's Avatar
HamfistRacing.com
Tenured Member 20 Years
iTrader: (5)
 
Joined: Jan 2003
Posts: 1,197
Likes: 4
From: NYC
Is that heavier than oem?
Reply
Old Jan 29, 2012 | 08:18 AM
  #158  
scotty R's Avatar
Senior Member
Tenured Member 15 Years
iTrader: (13)
 
Joined: Jan 2009
Posts: 401
Likes: 1
From: niagara , ON
Great write up , thanks for taking the time to do this , tons of good info
Reply
Old Jan 29, 2012 | 03:33 PM
  #159  
Adam R.'s Avatar
Junior Member
Tenured Member 05 Years
 
Joined: Nov 2009
Posts: 40
Likes: 0
From: Poland
Rx7_Nut13B how control speed of Stewart pump ? by PWM or simply 0-14V ?
Reply
Old Jan 29, 2012 | 09:45 PM
  #160  
jkstill's Avatar
Searching for 10th's
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (11)
 
Joined: May 2002
Posts: 2,275
Likes: 42
From: Portland OR
Originally Posted by s1mpsons
Is that heavier than oem?
900 grams = 1.9 lbs

Oem Water pump + housing weigh 8-9 lbs.
(just now weighed them on bathroom scales)
Reply
Old Jan 30, 2012 | 10:29 AM
  #161  
Rx7_Nut13B's Avatar
Red Neck Tony Stark - C2
Tenured Member 15 Years
iTrader: (1)
 
Joined: Aug 2002
Posts: 2,828
Likes: 1
From: Houston Tx
Originally Posted by Adam R.
Rx7_Nut13B how control speed of Stewart pump ? by PWM or simply 0-14V ?
The Stewarts pump is a brushless motor so it has a controller, it runs at 100% speed (55g/min)

You can proably figure out a way or controller that will change the speed but I didn't do that.

I have no T-stat and use my fan controls on the powerFc to control my engine temp. It takes some time to get up to temp but will hold about 170f-180f normal driving and never has been above 200f under hard driving.

I also run Evans coolant with 6psi rad cap.
Reply
Old Feb 9, 2012 | 07:17 PM
  #162  
nsk1's Avatar
modest beginnings
 
Joined: Jan 2012
Posts: 50
Likes: 0
From: springfield
anybody using one of these?

http://shop.pettitracing.com/pettit_.../i-408905.aspx
Reply
Old Feb 9, 2012 | 09:16 PM
  #163  
lOOkatme's Avatar
Rotary Enthusiast
Tenured Member: 20 Years
iTrader: (19)
 
Joined: Apr 2002
Posts: 1,171
Likes: 11
From: Colorado Springs, CO
Originally Posted by nsk1
I have a beck arnley thermostat......I paid I think $2 for it or something from rockauto a long time ago on special. It opens up at 180F.....another option for you. Its worked great for me.
Reply
Old Feb 9, 2012 | 09:20 PM
  #164  
s1mpsons's Avatar
HamfistRacing.com
Tenured Member 20 Years
iTrader: (5)
 
Joined: Jan 2003
Posts: 1,197
Likes: 4
From: NYC
I used the Pettit one for years. Worked well. Can still had heat issues on the track though, I suspect from issues unrelated to thermostat.
Reply
Old Feb 9, 2012 | 09:24 PM
  #165  
lOOkatme's Avatar
Rotary Enthusiast
Tenured Member: 20 Years
iTrader: (19)
 
Joined: Apr 2002
Posts: 1,171
Likes: 11
From: Colorado Springs, CO
I want to make a comment to educate more people here as well about cooling in general and altitude.

My car ran great at sea level altitudes....but when I brought the car to CO at higher altitude.....you really need to beef up the system and ducting is of the uttermost importance. Here are some charts too look at from a Ford guy who looked at how altitude effects air density....and how air density effects cooling properties.

In some cases....the rate of cooling drops 20-30%...which is huge. and since we have turbo cars....the car just spools up more to a higher PSI....which means WHP is uneffected.....which means you burn the same amt of fuel.....and you need to reject the same amount of heat as at sea level.....but now you have 20-30% less cooling capability with the same cooling system.

anyway...I went with dual oil coolers...and am ducting everything now. charts are below.
Attached Thumbnails The Big Fat FD3S Cooling Thread-5removal.jpg   The Big Fat FD3S Cooling Thread-4maf.jpg   The Big Fat FD3S Cooling Thread-2ram.jpg   The Big Fat FD3S Cooling Thread-3density.jpg   The Big Fat FD3S Cooling Thread-1boil.jpg  

Reply
Old Feb 9, 2012 | 11:35 PM
  #166  
jkstill's Avatar
Searching for 10th's
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (11)
 
Joined: May 2002
Posts: 2,275
Likes: 42
From: Portland OR
Originally Posted by lOOkatme
Here are some charts too look at from a Ford guy who looked at how altitude effects air density....and how air density effects cooling properties.
Got a link for that article?
Reply
Old Feb 10, 2012 | 06:05 PM
  #167  
lOOkatme's Avatar
Rotary Enthusiast
Tenured Member: 20 Years
iTrader: (19)
 
Joined: Apr 2002
Posts: 1,171
Likes: 11
From: Colorado Springs, CO
Originally Posted by jkstill
Got a link for that article?
http://www.ford-trucks.com/forums/65...-1-of-2-a.html

its off a forum.

I was searching for altitude and the effects of it on cooling systems. While his information was gathered for Ford trucks who pull heavy loads through the mountains with turbo's....the same information applies to any vehicle.
Reply
Old Jun 30, 2012 | 12:38 PM
  #168  
davesan1's Avatar
Full Member
Tenured Member 10 Years
iTrader: (4)
 
Joined: Aug 2003
Posts: 230
Likes: 0
From: Orange County, CA, USA
Cooling Fans, '93 - Ground Connections

Ground connections to fan motors

--------------------------------------------------------------------------------

On my 1993, depending on operational mode, 2 of the 4 fan inputs can be connected to ground . One of them only connects when relay # 3 is closed. The other should be permanently grounded via a solid connection to the body, (per the electrical manual). I think the fan ground connection to the body in my car has broken. Can anybody tell me where this connection is located on the body. It is the yellow wire which goes to both fan connectors and disappears into a cable harness at the front passenger side. All the other wires from the fans go into this same cable harness and come out at the 4 fan control relays on the passenger side. However, this yellow ground connection line does not emerge from the harness at all, (so far as I can see), so it must be (inteneded to to be) grounded on the body somewhere between the fan connectors and the 4 relays, but I'm dashed if I can see where! If anyone knows, or has a stripped down car in their garage and can easily take an unobstructed look in that area I would be most grateful.

Thanks

Dave
Reply
Old Jan 19, 2013 | 03:35 PM
  #169  
ZipRex's Avatar
Full Member
iTrader: (2)
 
Joined: May 2011
Posts: 109
Likes: 0
From: New Mexico
This is great. Just answered lots of questions with a couple of pictures.
Reply
Old May 25, 2013 | 09:14 AM
  #170  
maREX7's Avatar
Rotary Maniac
 
Joined: Feb 2012
Posts: 46
Likes: 0
From: Ireland
quick one about water pump gasket to the housing.

I've apparently stripped threads of lower alternator tensioner bracket bolt or either hole thread too due to rusty bolt. Now got a leaky coolant situation here from the WP housing at that point ...

So I'm taking it apart to inspect and I dont know if I can just clean off the surfaces and fasten using high temp silicone gasket maker only as a gasket replacement?
Reply
Old May 25, 2013 | 05:47 PM
  #171  
petros_rx7's Avatar
Senior Member
Tenured Member: 20 Years
 
Joined: Feb 2004
Posts: 400
Likes: 0
From: Greece
My setup for Greece temperatures ,summer up to 38 Celsius, koyo radiator 3 row ,99 spec fans,arc low temp thermostat 75 c, fan controller.
Temperature with any load or in city traffic never rise up to 92 celsius normally is about 86-88 c readings from pfc.
For heat soak I use electric pump, runs after switch off the engine with fans in mid scale for about 8 minutes.
Reply
Old May 25, 2013 | 08:41 PM
  #172  
metalCORE's Avatar
Senior Member
Tenured Member 15 Years
iTrader: (2)
 
Joined: Sep 2007
Posts: 349
Likes: 0
From: Germany
...take care of both flanges (they should be free of any seal residue and 100% flat), use a good sealant (like Hylomar) and let it dry through and it should work fine.

You can also use some gasket material and cut the sealing gasket by yourself, which should also work fine.
Reply
Old May 26, 2013 | 12:07 PM
  #173  
maREX7's Avatar
Rotary Maniac
 
Joined: Feb 2012
Posts: 46
Likes: 0
From: Ireland
Originally Posted by metalCORE
...take care of both flanges (they should be free of any seal residue and 100% flat), use a good sealant (like Hylomar) and let it dry through and it should work fine.

You can also use some gasket material and cut the sealing gasket by yourself, which should also work fine.
thanks for the advice man! I managed to clean out the block hole and get longer threaded stud and it went in like almost 10mm extra vs. original factory bolt which utilizes bare 5mm of its thread, so now its back to one piece will go start her soon to warm up and see how she behaves with leaking or better say NO LEAKING. if it neds to be tore down to where I need new gasket I will take your advice for sure! I do have some supercharger gasket sheets I can cut gasket from that and have RTV High Temp silicone, used for everything to deal with heat and flexibility.
Reply
Old May 29, 2013 | 11:47 AM
  #174  
roelof's Avatar
Junior Member
iTrader: (1)
 
Joined: Feb 2013
Posts: 10
Likes: 0
From: Curacao
learned allot from this impressive write up. GREAT JOB
Reply
Old May 29, 2013 | 01:13 PM
  #175  
RCCAZ 1's Avatar
Eats, Sleeps, Dreams Rotary
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (10)
 
Joined: Jun 2002
Posts: 3,367
Likes: 86
From: Phoenix, AZ
Originally Posted by petros_rx7
My setup for Greece temperatures ,summer up to 38 Celsius, koyo radiator 3 row ,99 spec fans,arc low temp thermostat 75 c, fan controller.
Temperature with any load or in city traffic never rise up to 92 celsius normally is about 86-88 c readings from pfc.
For heat soak I use electric pump, runs after switch off the engine with fans in mid scale for about 8 minutes.
That's nothing. We hit 43C here in the Summer in Phoenix (110F). Granted I only drive it sparingly during the Summer months, but it does "occasionally" get driven in those conditions and my temps stay about the same as those you've noted above
Reply