A/C Charging with Easy Cheap Safe Alternative Refrigerant
#305
1 Mo Gin
iTrader: (1)
If the system is still slighly pressurized, then none of the worst things have happened to the system-it likely doesn't have moisture in it, and you haven't lost any oil.
In your shoes, I would charge with *ONE* can of R152a. If the system runs and cools, you are golden. If it doesn't, you haven't lost any ground. Then take the long road.
Good Luck.
In your shoes, I would charge with *ONE* can of R152a. If the system runs and cools, you are golden. If it doesn't, you haven't lost any ground. Then take the long road.
Good Luck.
#306
The AC in my 91 FC that I purchased 7 months ago would blow sort of cold when I first purchased it but in the past month I am getting nothing but hot air. It definitely works though so my first step is to recharge with one can of R152a, correct ? Being a fairly new owner should I be worried that the previous owner could have used R134a to recharge it previously ?
You should address that leak first. Then the first step is to read here: https://www.rx7club.com/2nd-generati...gerant-964688/
Last edited by jackhild59; 07-22-15 at 09:07 AM.
#308
Originally Posted by setupfc3s
Hello,
Wanted to say thanks for all the info on the r152a in the thread you started years ago, been a lot of help!. Going to fill mine up today so soon as it gets hotter. But wanted to see if you can confirm about how many oz I should need of the duster. I have a 10oz can. Will I need more you think? 88deg and 50% humidity. I did see a lot of info for the FC but not that I saw for the FD. It's a 93.
Thanks!!
Wanted to say thanks for all the info on the r152a in the thread you started years ago, been a lot of help!. Going to fill mine up today so soon as it gets hotter. But wanted to see if you can confirm about how many oz I should need of the duster. I have a 10oz can. Will I need more you think? 88deg and 50% humidity. I did see a lot of info for the FC but not that I saw for the FD. It's a 93.
Thanks!!
Good Luck!
The following users liked this post:
RXSpeed16 (09-10-21)
#309
MECP Certified Installer
I was just looking at the MSDS of Freeze 12 and it is a mixture of r-134 and r-142 (r-134, not r-134a).
I thought r-134 wasn't a good refrigerant, or is Johnsens freeze 12 junk?
I thought r-134 wasn't a good refrigerant, or is Johnsens freeze 12 junk?
#310
Freeze12 is a good product for what it is. The original problem converting R12 to R134a is that the mineral oil is not miscible in 134a . That can caused the mineral oil to collect in the drier instead of circulating in the system.
Freeze12 adds the R142 because it will carry the mineral oil around the system. It also has a lower operating pressure than R134a
This doesn't change the problem with our RX7's mainly being that we do not have enough condenser for 134a.
Freeze12 works ok, better than straight R134a, not as good as R152a.
Backup camera is working, USB plug to replace the cig lighter arrives via amazon tomorrow. I really appreciate your help, Jjwalker!
#311
Rotary Enthusiast
iTrader: (8)
Join Date: Mar 2004
Location: Ontario
Posts: 1,036
Likes: 0
Received 0 Likes
on
0 Posts
GREAT READ~! thanks for the vid, i was shown this refridge school but could not find it. love telling ppl about that vid Y not to use propane type gas.
funny my danfoss PT chart app has 152a listed, il have to order me some new tools this week
funny my danfoss PT chart app has 152a listed, il have to order me some new tools this week
#312
Wow that is a lot to read. Jackhild59 you really know your stuff! I didn't know the stuff used to clean my computer was a refrigerant (152a). I'm going to try this on my 1990 R12 system. Disconnecting all AC lines. spraying brake cleaner through them and blowing lines out with 80psi compressed air. Replacing all O-rings. New AC condenser, AC compressor and new drier. Mike
#313
Ok All torn apart and blown out. Need some clarification. I hear the 134a system works with higher pressures than the R12 system. Does this mean that the 134a compressor compresses the refrigerant to a higher psi than the R12 compressor can? I have a few other questions also. I just want to be sure I'm going to do this correctly. I'm not an AC man by no means. Mike
#314
MECP Certified Installer
R134a is a fine refrigerant but our RX7's don't have enough condensing capacity for it to work well.
Freeze12 is a good product for what it is. The original problem converting R12 to R134a is that the mineral oil is not miscible in 134a . That can caused the mineral oil to collect in the drier instead of circulating in the system.
Freeze12 adds the R142 because it will carry the mineral oil around the system. It also has a lower operating pressure than R134a
This doesn't change the problem with our RX7's mainly being that we do not have enough condenser for 134a.
Freeze12 works ok, better than straight R134a, not as good as R152a.
Backup camera is working, USB plug to replace the cig lighter arrives via amazon tomorrow. I really appreciate your help, Jjwalker!
Freeze12 is a good product for what it is. The original problem converting R12 to R134a is that the mineral oil is not miscible in 134a . That can caused the mineral oil to collect in the drier instead of circulating in the system.
Freeze12 adds the R142 because it will carry the mineral oil around the system. It also has a lower operating pressure than R134a
This doesn't change the problem with our RX7's mainly being that we do not have enough condenser for 134a.
Freeze12 works ok, better than straight R134a, not as good as R152a.
Backup camera is working, USB plug to replace the cig lighter arrives via amazon tomorrow. I really appreciate your help, Jjwalker!
#315
Rotary Enthusiast
iTrader: (1)
We had a "pro R134a conversion" done several years ago and the A/C has worked fine all that time until late last year. So I was going to try the R152 but have been stumped by what I think was an incomplete conversion.
The low side has a clean fitting but my HF R134a gauge coupler doesnt seem to fit.
High side?
Low side
Any suggestions for next steps? If my understanding is correct the a/c is a bit more frankenstein that expected.
Thanks!
Jim
The low side has a clean fitting but my HF R134a gauge coupler doesnt seem to fit.
High side?
Low side
Any suggestions for next steps? If my understanding is correct the a/c is a bit more frankenstein that expected.
Thanks!
Jim
#316
Rotary Enthusiast
iTrader: (1)
Nevermind. I was being a Honduh owner. The spring clamp for the BAC water feed was preventing the coupling from attaching. And I see I need to go pick up an adapter for the high side.
If I'm reading the low side gauge correctly, it current has almost 6 bar static on the low side.
btw, anyone else find that the URL option for pictures doesnt work? As soon as I start typing (Chrome) the "t" in "http..." it clears the field.
Thx,
Jim
If I'm reading the low side gauge correctly, it current has almost 6 bar static on the low side.
btw, anyone else find that the URL option for pictures doesnt work? As soon as I start typing (Chrome) the "t" in "http..." it clears the field.
Thx,
Jim
#317
I
iTrader: (6)
that's about where my pressure reading on my fd is at when off 85psi ish I just did r134a conversion on mine ( from having nothing for years)
did u start with the basics? when u turn the AC on does the compressor clutch engage?
if not u could try jumpering the compressor wire temporarily and force it to kick on ( if you know the system has pressure)
if it works then, take a look ad the pressure switch see if it ohms out correctly
there will also be a thermos swtich for it to shut off in the evaporator as well
resistance values should be in the FSM
did u start with the basics? when u turn the AC on does the compressor clutch engage?
if not u could try jumpering the compressor wire temporarily and force it to kick on ( if you know the system has pressure)
if it works then, take a look ad the pressure switch see if it ohms out correctly
there will also be a thermos swtich for it to shut off in the evaporator as well
resistance values should be in the FSM
#318
Rotary Enthusiast
iTrader: (1)
The compressor comes on. When driving and turning on the a/c the additional load on the engine is obvious.
I'm going to put the R152 in with a new drier and see where we are on the gauges. The drier doesnt arrive until Monday. Orreily's doesn't stock them locally anymore so it has to be shipped in from Georgia. And I couldn't find any on Amazon (yay Prime!), Advanced, Autozone or RockAuto that had the welded on bracket.
I'm going to put the R152 in with a new drier and see where we are on the gauges. The drier doesnt arrive until Monday. Orreily's doesn't stock them locally anymore so it has to be shipped in from Georgia. And I couldn't find any on Amazon (yay Prime!), Advanced, Autozone or RockAuto that had the welded on bracket.
#319
MECP Certified Installer
Jack, I do have a question for you.
I have reread the beginning of the thread about 10 times now and this is what causes me to have this question.
"152a is not miscible with mineral oil"
Since we didnt dump out the compressor, and I believe we put 3oz of ester in the drier assembly, am I still getting good compressor lucrication?
I still blows nice and cold even in the 105+ weather we have been having but now I am concerned about lubrication of the compressor.
I have reread the beginning of the thread about 10 times now and this is what causes me to have this question.
"152a is not miscible with mineral oil"
Since we didnt dump out the compressor, and I believe we put 3oz of ester in the drier assembly, am I still getting good compressor lucrication?
I still blows nice and cold even in the 105+ weather we have been having but now I am concerned about lubrication of the compressor.
#322
shouldn't the new compressor be drained of factory oil? measured then refilled with the same amount of ester oil instead of the factory oil? I drained about 3oz out of the new compressor and replaced with 3 oz of ester oil. my system holds about 6 oz of oil so I'm guessing that I need to add 3 more oz's of ester to the dryer and I'll have correct amount of oil. RIGHT? Mike
Last edited by liznmike; 08-08-15 at 11:37 AM.
#324
Jack, I do have a question for you.
I have reread the beginning of the thread about 10 times now and this is what causes me to have this question.
"152a is not miscible with mineral oil"
Since we didnt dump out the compressor, and I believe we put 3oz of ester in the drier assembly, am I still getting good compressor lucrication?
I still blows nice and cold even in the 105+ weather we have been having but now I am concerned about lubrication of the compressor.
I have reread the beginning of the thread about 10 times now and this is what causes me to have this question.
"152a is not miscible with mineral oil"
Since we didnt dump out the compressor, and I believe we put 3oz of ester in the drier assembly, am I still getting good compressor lucrication?
I still blows nice and cold even in the 105+ weather we have been having but now I am concerned about lubrication of the compressor.
We took out some, probably about half, of the oil you had currently in the system with the drier. It was most likely mineral oil. We added in 3, maybe 4 oz of ester. The ester will carry through the system and you will be fine lubrication wise.
I did it this same way on my 10th Anny back in June and it works just fine for now.
When I do my new parallel-flow condenser on the 10th Anny I will put another new drier on and do a full flush on the compressor. At that point I will have a completely empty condenser, drier and compressor. I will add the exact 6 oz of ester to the system at that time.
#325
shouldn't the new compressor be drained of factory oil? measured then refilled with the same amount of ester oil instead of the factory oil? I drained about 3oz out of the new compressor and replaced with 3 oz of ester oil. my system holds about 6 oz of oil so I'm guessing that I need to add 3 more oz's of ester to the dryer and I'll have correct amount of oil. RIGHT? Mike