2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.

Best way to do E-Fan

Thread Tools
 
Search this Thread
 
Old Apr 4, 2012 | 10:22 AM
  #1  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Best way to do E-Fan

Hey guys,

I have an E-Fan setup on my turbo car from the previous owner. Yesterday when I got home from work I noticed my car was a little hotter than normal, about 1/3 up the gauge vs the typical 1/4; turns out my E-Fan never came on.

After realizing some of the wires have burnt themselves at the connectors do to excessive load, I wondered if there is a better way to wire the E-Fan.

Currently, the fan is wired to a 180 degree temp sensor located behind the water pump. The problem with this is since the temp sensor is in the block, the moment the block warms up the E-Fan comes on; meaning it does not shut off once it comes on and the car is running. After I turn the car off, it continues to stay on until the block cools down, which could take 20 minutes.

Is that the normal way of doing things? Is there a better way of doing it? How can I prevent the wires from eventually burning up again? I have heard of coolant hose adapters so you can have a switch in the coolant hose. Is that better? Thanks for any help.

Here is a pic of my car:
Reply
Old Apr 4, 2012 | 11:41 AM
  #2  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
Are you using any relay's or are you hooked directly to the sensor? Your post is not clear.

A 1/4" spade connector is rated at 30 amps max. If your fan pulls more (or even close) you will get some heating. Eventually you get melting. Solution is to use a high amperage relay that has 3/8" connectors for the load. Proper crimp or ring connections other places will eliminate the heating.

Also, pull those 4 studs out of the waterpump hub. Those things will wind you up if you ever get too close.
Reply
Old Apr 4, 2012 | 01:26 PM
  #3  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Originally Posted by jackhild59
Are you using any relay's or are you hooked directly to the sensor? Your post is not clear.

A 1/4" spade connector is rated at 30 amps max. If your fan pulls more (or even close) you will get some heating. Eventually you get melting. Solution is to use a high amperage relay that has 3/8" connectors for the load. Proper crimp or ring connections other places will eliminate the heating.

Also, pull those 4 studs out of the waterpump hub. Those things will wind you up if you ever get too close.
Thank you that is very good info

I am using a relay btw, with ground going to a 40amp fuse in the fuse block.

Pic of relay:
Reply
Old Apr 4, 2012 | 01:58 PM
  #4  
JerryLH3's Avatar
Rabbit hole specialist
Tenured Member: 25 Years
Community Favorite
iTrader: (11)
 
Joined: Feb 2001
Posts: 2,852
Likes: 225
From: Tampa, FL
I'd look into a temp switch with a higher setting once the wiring issues are sorted. I think having it come on at 180F is too cool.
Reply
Old Apr 4, 2012 | 02:00 PM
  #5  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
This is what you need:

http://www.parts-express.com/pe/show...number=075-140
Reply
Old Apr 4, 2012 | 02:10 PM
  #6  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Thanks for the info guys

Question: Is it good to have the temp switch behind the water pump in the block? Or should I move it to the upper radiator hose before the T-stat?
Reply
Old Apr 4, 2012 | 02:13 PM
  #7  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
What temp switch are you using? Edit: Nevermind, I see in your first post that the switch is 180*.

I am using a 195* switch in my radiator inlet. It does the same as yours does in warm weather. I have the control current wired so that when the key goes off, the fan goes off.
Reply
Old Apr 4, 2012 | 08:54 PM
  #8  
R0tor R00ter's Avatar
Full Member
iTrader: (1)
 
Joined: Mar 2011
Posts: 103
Likes: 0
From: Carbondale, IL
Here is a solution. Put the clutch fan back on and be done with it. E fan doesnt do much for you anyway besides use more voltage. You wont get more power from it so it is pointless. The only thing it may be good for is to clear up space under the hood.
Reply
Old Apr 4, 2012 | 09:24 PM
  #9  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Originally Posted by R0tor R00ter
Here is a solution. Put the clutch fan back on and be done with it. E fan doesnt do much for you anyway besides use more voltage. You wont get more power from it so it is pointless. The only thing it may be good for is to clear up space under the hood.
Here is where I iterate that after owning 8 FCs, not having a fan clutch and radiator shroud to deal with gives me a humungous boner

Anyways, I am not here to debate whether or not to use one, I am here just to ask where the optimal position to put the switch is. Any info would be great
Reply
Old Apr 4, 2012 | 10:08 PM
  #10  
R-X-R's Avatar
Rotary Enthusiast
Tenured Member 05 Years
iTrader: (9)
 
Joined: Jun 2011
Posts: 805
Likes: 4
From: Syracuse,NY
8 FC's? who r u ?
Reply
Old Apr 5, 2012 | 05:36 AM
  #11  
clokker's Avatar
Cake or Death?
Tenured Member 10 Years
iTrader: (2)
 
Joined: Jan 2007
Posts: 10,249
Likes: 64
From: Mile High
Originally Posted by R0tor R00ter
Here is a solution. Put the clutch fan back on and be done with it. E fan doesnt do much for you anyway besides use more voltage. You wont get more power from it so it is pointless. The only thing it may be good for is to clear up space under the hood.
Clearly you know nothing about electric fans and how they can be operated.

@funkjaw:
One way to install the fan, here.
Reply
Old Apr 5, 2012 | 07:53 AM
  #12  
Puck's Avatar
Senior Member
Tenured Member 15 Years
iTrader: (1)
 
Joined: Sep 2002
Posts: 357
Likes: 0
From: Terrace Bay, Ontario
That is the biggest relay I have ever seen!!! It's bigger than your battery!
Reply
Old Apr 5, 2012 | 10:51 AM
  #13  
R0tor R00ter's Avatar
Full Member
iTrader: (1)
 
Joined: Mar 2011
Posts: 103
Likes: 0
From: Carbondale, IL
Originally Posted by clokker
Clearly you know nothing about electric fans and how they can be operated.

@funkjaw:
One way to install the fan, here.
Clearly you dont know how the fan system works on a rx7 and when it is neccessary to have a fan running or not. Read this and it might help you.http://www.aaroncake.net/rx-7/efanmyth.htm
Reply
Old Apr 5, 2012 | 11:19 AM
  #14  
clokker's Avatar
Cake or Death?
Tenured Member 10 Years
iTrader: (2)
 
Joined: Jan 2007
Posts: 10,249
Likes: 64
From: Mile High
I disagree with your interpretation of Mr. Cake's article- your takeaway ("E fan doesnt do much for you anyway besides use more voltage") is much narrower than his and he even links to his own writeup on how to perform the conversion.

Anyway, as funkjaw pointed out, this is not a discussion about whether but how.
Reply
Old Apr 5, 2012 | 11:20 AM
  #15  
verrt's Avatar
Full Member
Tenured Member 05 Years
 
Joined: Feb 2006
Posts: 69
Likes: 0
From: NY
I'm laughing at the giant relay
Reply
Old Apr 5, 2012 | 02:47 PM
  #16  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
Originally Posted by verrt
I'm laughing at the giant relay
Pretty cool, huh? Sitting right on top of that 2-story high battery.

I guess it's all really a matter of perspective.
Reply
Old Apr 5, 2012 | 04:45 PM
  #17  
R0tor R00ter's Avatar
Full Member
iTrader: (1)
 
Joined: Mar 2011
Posts: 103
Likes: 0
From: Carbondale, IL
Originally Posted by clokker
I disagree with your interpretation of Mr. Cake's article- your takeaway ("E fan doesnt do much for you anyway besides use more voltage") is much narrower than his and he even links to his own writeup on how to perform the conversion.

Anyway, as funkjaw pointed out, this is not a discussion about whether but how.
That would be why I put that link up!
Reply
Old Apr 5, 2012 | 05:39 PM
  #18  
stevensimon's Avatar
Banned. I got OWNED!!!
iTrader: (11)
 
Joined: Aug 2003
Posts: 3,575
Likes: 6
From: salt lake ut
wire your relay 12+ to an acc source and not straight to a 12+ constant. key off=fan off. also at such a low temp for the fan switch, i would put it in the back of the water pump housing. blowing off water in the radiator does little to water stagnant in the back of the block. especially if the engine is off.
Reply
Old Apr 9, 2012 | 12:12 PM
  #19  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Thanks everyone for your help.

I will be:
-Putting switch in upper radiator hose
-Using a higher temp switch
-Using the better relay with larger spade connectors
-Feeding 12v off a non constant

Again, thanks for all the help.
Reply
Old Apr 9, 2012 | 03:35 PM
  #20  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Question, if running the thermostat switch in the upper radiator hose near the radiator, what temperature should I use? I found a couple two prong thermostat switches on summit racing, one of them turns on at 195 and turns off at 185. The other turns on at 185 and turns off at 175.

Any thoughts?
Reply
Old Apr 9, 2012 | 03:38 PM
  #21  
clokker's Avatar
Cake or Death?
Tenured Member 10 Years
iTrader: (2)
 
Joined: Jan 2007
Posts: 10,249
Likes: 64
From: Mile High
My fan trigger is in the upper rad hose, low speed turns on at 195°, high at 210°.
Reply
Old Apr 9, 2012 | 04:01 PM
  #22  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Originally Posted by clokker
My fan trigger is in the upper rad hose, low speed turns on at 195°, high at 210°.
Do you have problems with the fan staying on too long after you shut the engine off? Or do you have it wired to only be on with ignition on?
Reply
Old Apr 9, 2012 | 05:37 PM
  #23  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
So found this unused bung on the bottom of my Koyo (probably because it is an NA S4 Koyo)

Wondering if that would be a good place to put a thermostat switch? The switch would be making no contact with the actual fluid. Any thoughts?

Reply
Old Apr 9, 2012 | 05:56 PM
  #24  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
Originally Posted by funkjaw
Question, if running the thermostat switch in the upper radiator hose near the radiator, what temperature should I use? I found a couple two prong thermostat switches on summit racing, one of them turns on at 195 and turns off at 185. The other turns on at 185 and turns off at 175.

Any thoughts?
I'm using a Summit switch, single prong. 195* on 185 off, upper radiator tank near the inlet of the rad.

http://www.summitracing.com/parts/SUM-890018/

Originally Posted by funkjaw
So found this unused bung on the bottom of my Koyo (probably because it is an NA S4 Koyo)

Wondering if that would be a good place to put a thermostat switch? The switch would be making no contact with the actual fluid. Any thoughts?

No, the bottom of that rad will cause you to measure the coolant after it's already cooled. Your fan will not run till the engine coolant is way too hot at idle and slow rates of speed. I tried that location years ago by drilling out that well so the probe would contact the coolant. I installed a temperature sender for my VDO gauge to get an idea of the possiblities. The temps were very very erratic. Don't do it.
Reply
Old Apr 9, 2012 | 07:02 PM
  #25  
funkjaw's Avatar
Thread Starter
Rotary Freak
Tenured Member 15 Years
iTrader: (3)
 
Joined: Jul 2008
Posts: 2,515
Likes: 4
From: San Jose, CA (NorCal/S.F. Bay Area)
Originally Posted by jackhild59
I'm using a Summit switch, single prong. 195* on 185 off, upper radiator tank near the inlet of the rad.

http://www.summitracing.com/parts/SUM-890018/



No, the bottom of that rad will cause you to measure the coolant after it's already cooled. Your fan will not run till the engine coolant is way too hot at idle and slow rates of speed. I tried that location years ago by drilling out that well so the probe would contact the coolant. I installed a temperature sender for my VDO gauge to get an idea of the possiblities. The temps were very very erratic. Don't do it.
Thank you sir!

Since you are in the radiator itself, I take it that is how you got away with using a single prong? I would imagine since I want to put it inline with one of those adapters in the upper radiator hose that I would need to get a two prong so I could ground it?
Reply