2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.

Auto Radiator in Manual Car?

Thread Tools
 
Search this Thread
 
Old Feb 8, 2007 | 12:01 PM
  #1  
sanbaifo's Avatar
Thread Starter
Junior Member
Tenured Member 05 Years
 
Joined: Mar 2004
Posts: 22
Likes: 0
From: Into the great wide open...
Auto Radiator in Manual Car?

I have a 88 GTU that has a crack in the plastic radiator cap assembly (it connects to the radiator with two bolts). I found a good deal on a new all metal radiator but it's supposed to be for an automatic. Will it work OK?

Thanks
Reply
Old Feb 8, 2007 | 02:37 PM
  #2  
skrewloose78's Avatar
Anti-rice Superstar
Tenured Member 10 Years
 
Joined: Sep 2002
Posts: 949
Likes: 0
From: huntsville,alabama
yeah that will be just fine.
Reply
Old Feb 8, 2007 | 02:38 PM
  #3  
dopefishlives's Avatar
Grand Poobah of Torque
Tenured Member 10 Years
 
Joined: Jun 2006
Posts: 186
Likes: 0
From: Clermont, Florida
Yea either model will function the sale. The automatics have a cooling coil that resides in the lower endtank, it will just sit dormant in the manual car, no worries.

_Kris
Reply
Old Feb 8, 2007 | 02:44 PM
  #4  
jackhild59's Avatar
Rotary $ > AMG $
Tenured Member: 20 Years
iTrader: (7)
 
Joined: Apr 2005
Posts: 3,785
Likes: 30
From: And the horse he rode in on...
Yes, it will work fine. The difference is that aftermarket radiators, unless they are 'racing' versions are usually made to fit both manual and automatics. the main difference is that there is a cooling loop added to cool the automatic transmission. This is simply not hooked up and used if you have a manual transmission.

I have one of these 'automatic' all metal radiators in my 90 Vert. It works fine in Dallas heat with or with out A/C, in stop and go traffic or at highway speeds. I have the engine driven fan and shroud, the underbelly pan on the car and I have a Mazda oem thermostat.

BTW, on some cars, the radiator is oversized to handle the transmission heat, so when the aftermarket company sizes the unit, you actually get an upgrade on the radiator. It was this way on my wife's 92 Celica Vert. The oem plastic tank rad split. The all metal automatic version was a half inch thicker core and was a two row setup compared to the single row core on the manual. I researched this and found that Toyota used the thicker radiator to handle the tranny heat. Aftermarket just made the auto unit. It may be the same thing on the rx7 radiator.

Good luck!
Reply
Old Feb 8, 2007 | 02:58 PM
  #5  
slow_2ed_gen's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Jun 2005
Posts: 624
Likes: 1
From: fort myers beach, FL
my 89 gxl manual has an auto radiator and it runs fine