3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Twins inlet & outlet stud question

Thread Tools
 
Search this Thread
 
Old 08-17-14, 04:49 PM
  #1  
Junior Member
Thread Starter
iTrader: (2)
 
Cesarivan84's Avatar
 
Join Date: Jul 2013
Location: FORT WORTH , TEXAS
Posts: 25
Likes: 0
Received 0 Likes on 0 Posts
Twins inlet & outlet stud question

Anyone happen to know what the torque specs are for the studs on the turbo inlet and outlet studs? I can't seem to find it in workshop manual. Thanks , Cesar
Old 08-17-14, 05:16 PM
  #2  
Hey...Cut it out!

iTrader: (4)
 
Akagis_white_comet's Avatar
 
Join Date: Dec 2007
Location: St Louis, MO
Posts: 2,067
Received 295 Likes on 191 Posts
69.5-95.4 in.lbs (5.8 - 8 ft.lbs) is the torque spec for both the twins inlets and outlets. I usually just torque them to 7 and call it a day.
Old 08-17-14, 05:28 PM
  #3  
Junior Member
Thread Starter
iTrader: (2)
 
Cesarivan84's Avatar
 
Join Date: Jul 2013
Location: FORT WORTH , TEXAS
Posts: 25
Likes: 0
Received 0 Likes on 0 Posts
Thank you