PRoFec B spec II help!
#1
Senior Member
Thread Starter
iTrader: (2)
Join Date: Oct 2001
Location: Orange County, CA
Posts: 456
Likes: 0
Received 0 Likes
on
0 Posts
PRoFec B spec II help!
Hey list,
well i hooked up everything, and i'm hitting .72kpa=10.4psi and that's '[lo] set' 0%. What should i do? if i turn off my controller, i should only go up to 7psi, correct? Maybe i install the vac. hose incorrectly. I had the line go from head unit to filter to Upper Intake manifold.
What should i do?
Thanks
-joe
well i hooked up everything, and i'm hitting .72kpa=10.4psi and that's '[lo] set' 0%. What should i do? if i turn off my controller, i should only go up to 7psi, correct? Maybe i install the vac. hose incorrectly. I had the line go from head unit to filter to Upper Intake manifold.
What should i do?
Thanks
-joe
Trending Topics
#9
Full Member
Join Date: May 2002
Location: Irvine, CA
Posts: 185
Likes: 0
Received 0 Likes
on
0 Posts
What exactly is your question? I just installed a Profec B Spec II recently and it works fine, 7 psi when off. Are you using the correct ports on the solenoid? There are three, make sure you use the one that's for actuator type installations.
Also, make sure to cap off the other side of the actuator that goes up the pipes and to the wastegate solenoid. The wastegate solenoid isn't used anymore.
Also, make sure to cap off the other side of the actuator that goes up the pipes and to the wastegate solenoid. The wastegate solenoid isn't used anymore.
#10
Senior Member
iTrader: (1)
Join Date: Sep 2001
Location: SE MI
Posts: 274
Likes: 0
Received 0 Likes
on
0 Posts
hey mor,
did you try a different power srce yet?
and which do think gives a more accurate reading...the profec or the autometer boost guage? I thought the profec was right since it read 7 psi when i had it off....i guess i'll take a look tonite when i get back.
did you try a different power srce yet?
and which do think gives a more accurate reading...the profec or the autometer boost guage? I thought the profec was right since it read 7 psi when i had it off....i guess i'll take a look tonite when i get back.
#11
Full Member
Join Date: May 2002
Location: Irvine, CA
Posts: 185
Likes: 0
Received 0 Likes
on
0 Posts
sup alien7,
nope haven't had a chance to try another power source.
yeah, i think the profec is correct.
before i try the power source i'm gonna try changing my installation to the standard wastegate only instead of t'ing both wg and pc.
how do you have yours installed? i'm getting 10-6-10...so i think i'll put the pc back. what size pill do i need? 0.059"?
nope haven't had a chance to try another power source.
yeah, i think the profec is correct.
before i try the power source i'm gonna try changing my installation to the standard wastegate only instead of t'ing both wg and pc.
how do you have yours installed? i'm getting 10-6-10...so i think i'll put the pc back. what size pill do i need? 0.059"?
#12
Senior Member
iTrader: (1)
Join Date: Sep 2001
Location: SE MI
Posts: 274
Likes: 0
Received 0 Likes
on
0 Posts
hey mor
i only have the controller hooked up to the wastegate....didn't touch the precontrol.
I also have a 10-6-10 pattern....i wonder why that is. Not sure what the pill size is....you didn't hold on to that hose?
i only have the controller hooked up to the wastegate....didn't touch the precontrol.
I also have a 10-6-10 pattern....i wonder why that is. Not sure what the pill size is....you didn't hold on to that hose?
Thread
Thread Starter
Forum
Replies
Last Post
edgars95rx7
Link Vi-PEC
0
10-01-15 01:59 PM
joel(PA)
Race Car Tech
0
10-01-15 10:25 AM