3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Plastice Pipe Under Oil Pressure Sender?

Thread Tools
 
Search this Thread
 
Old Nov 14, 2008 | 10:53 PM
  #1  
FallenCho's Avatar
Thread Starter
Senior Member
Tenured Member 15 Years
iTrader: (1)
 
Joined: Aug 2005
Posts: 496
Likes: 0
From: NV
Plastice Pipe Under Oil Pressure Sender?

What is that plastic pipe that is located directly under the oil pressure sender? There is a hose going to it from the passenger side of the firewall and I ended up breaking the plastic part when I pulled the hose off of it so I need to give Ray a call but I have no idea what to ask for and I don't see it in the FSM under cooling or the engine section. :-/
Reply
Old Nov 14, 2008 | 10:57 PM
  #2  
cewrx7r1's Avatar
Eye In The Sky
Tenured Member: 25 Years
iTrader: (2)
 
Joined: Feb 2001
Posts: 7,941
Likes: 133
From: In A Disfunctional World
If you had looked into the MAZDA manual, you would have learned that it is the water hose going into the heater.
Reply
Old Nov 14, 2008 | 11:03 PM
  #3  
PandazRx-7's Avatar
Fast + Reliable = $$$$$
Tenured Member: 20 Years
iTrader: (18)
 
Joined: Nov 2003
Posts: 1,223
Likes: 4
From: SoCal
I never understood why Mazda made that connection the way they did...seems like everyones had them break on them, after years of use they get brittle like the stock AST. I think a regular hose clamp would have done a better job.
Reply
Old Nov 14, 2008 | 11:13 PM
  #4  
FallenCho's Avatar
Thread Starter
Senior Member
Tenured Member 15 Years
iTrader: (1)
 
Joined: Aug 2005
Posts: 496
Likes: 0
From: NV
I knew it was for the heater but I just don't understand why it's connected to a plastic piece from the engine side...didn't know if it had some special purpose or not.
Reply
Old Nov 15, 2008 | 12:05 AM
  #5  
alexdimen's Avatar
TANSTAFL
Tenured Member 15 Years
iTrader: (13)
 
Joined: Oct 2003
Posts: 3,770
Likes: 128
From: Richmond, Va.
It's a quick-disconnect. You can get a Dorman replacement kit for it since it's interchangable with a Ford Aerostar part.
Reply
Old Nov 15, 2008 | 08:56 AM
  #6  
GARCO MOTORWORKS's Avatar
Banned. I got OWNED!!!
 
Joined: Jul 2004
Posts: 1,179
Likes: 1
From: next to the polishing wheel!!!
Just remove the plastic and put the hose directly on the metal tube from the motor . Life is good .
Reply
Old Nov 15, 2008 | 09:04 AM
  #7  
bajaman's Avatar
Constant threat
Tenured Member 20 Years
 
Joined: Jul 2001
Posts: 4,968
Likes: 39
From: near Wichita, Kansas
Originally Posted by alexdimen
It's a quick-disconnect. You can get a Dorman replacement kit for it since it's interchangable with a Ford Aerostar part.
This is the best advice in this thread (and everytime this comes up...). Keep the car as stock as possible. Especially when you can go to any AUTOZONE or O'Reilly's and pick it up for about $12.

Reply
Old Nov 15, 2008 | 06:17 PM
  #8  
Dudemaaanownsanrx7's Avatar
wannaspeed.com
Tenured Member 20 Years
iTrader: (23)
 
Joined: Feb 2003
Posts: 2,802
Likes: 5
From: Texas
remove it and put a hose clamp. that thing is just a problem waiting.
Reply
Old Nov 15, 2008 | 06:38 PM
  #9  
RLaoFD's Avatar
Brappable not Unflappable
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (7)
 
Joined: May 2005
Posts: 1,392
Likes: 8
From: Bay Area
Originally Posted by GARCO MOTORWORKS
Just remove the plastic and put the hose directly on the metal tube from the motor . Life is good .
+1, make sure the hose clamp is nice and tight and it isn't going anywhere.
Reply
Old Nov 15, 2008 | 09:37 PM
  #10  
IRPerformance's Avatar
Sponsor
iTrader: (41)
 
Joined: Apr 2003
Posts: 11,347
Likes: 321
From: NJ
It does absolutely nothing except break and leak. The only thing I can think of is Mazda thought it would serve as some kind of quick release or maybe they thought the hose was less likely to get stuck to the plastic pipe vs the metal one. It does neither of these too well. I take those off on every motor I build and just slip the heater hose over the metal pipe, and secure it with a decent worm gear hose clamp.
Reply
Old Nov 15, 2008 | 09:46 PM
  #11  
FallenCho's Avatar
Thread Starter
Senior Member
Tenured Member 15 Years
iTrader: (1)
 
Joined: Aug 2005
Posts: 496
Likes: 0
From: NV
Sweet thanks for the replies I didn't know if it had any special purpose like I said so I figured I'd just replace it but whatever I can do to cut costs on my current build up. Still need to place a second order with Ray
Reply
Old Nov 15, 2008 | 11:06 PM
  #12  
FutileLover's Avatar
Project FD
Tenured Member 15 Years
iTrader: (1)
 
Joined: Jan 2007
Posts: 97
Likes: 1
From: Sacramento
i recommend replacing the plastic coupling (stock)

the metal pipe doesnt have a lip, with just a clamp its likely to slip off

if yours hasnt slipped off yet, doesnt matter, my coupling hasnt broke yet either (but i replaced it anyways)

preventative maintenance
Reply
Old Nov 16, 2008 | 08:26 AM
  #13  
GARCO MOTORWORKS's Avatar
Banned. I got OWNED!!!
 
Joined: Jul 2004
Posts: 1,179
Likes: 1
From: next to the polishing wheel!!!
I have never had one slip off and how many have I done ? I will break , remove good ones because they will rot and break sometime down the road . Do it once and keep going .
Reply
Old Nov 16, 2008 | 08:57 AM
  #14  
badddrx7's Avatar
All Spooled Up
Tenured Member 15 Years
iTrader: (7)
 
Joined: Nov 2001
Posts: 2,752
Likes: 3
From: Ironton,ohio
I pulled the metal nipple out of the housing and cast weld up the holes on all three of my FDs. I do not run a Heater/AC unit. I know this may not be what you are doing but to those who do not run a heater you might consider this. Long ago I tried a hose cap over that nipple and after some age it started to crack. Loss of coolant here would be terrible.

You can't even tell a nipple was there.
Attached Thumbnails Plastice Pipe Under Oil Pressure Sender?-dsc01345.jpg  
Reply
Old Nov 16, 2008 | 08:58 AM
  #15  
Tom93R1's Avatar
gross polluter
Tenured Member: 25 Years
iTrader: (2)
 
Joined: Mar 2001
Posts: 1,757
Likes: 25
From: Chandler, AZ
It certainly is not a "quick disconnect" as there is nothing quick about figuring out how to disconnect it. Everybody knows what you are talking about when you say "quick disconnect" though.

Its there to make engine installation at the factory easier, as that spot is a pain in the *** to get to and by using it the installer doesn't need to fiddle with hose clamps. So really the part is a "quick connect"
Reply
Old Nov 16, 2008 | 03:26 PM
  #16  
IRPerformance's Avatar
Sponsor
iTrader: (41)
 
Joined: Apr 2003
Posts: 11,347
Likes: 321
From: NJ
It won't slip off it you use a proper clamp. Don't re-use the stock clamp in this application.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Snoopy FD
Build Threads
25
Dec 8, 2015 01:45 PM
stickmantijuana
20B Forum
8
Aug 18, 2015 02:46 PM




All times are GMT -5. The time now is 06:44 PM.