3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

HELP!!!! Non-sequential problem.

Thread Tools
 
Search this Thread
 
Old 06-09-02, 02:15 AM
  #1  
Altitude SUCKS!!!

Thread Starter
 
Dr Wankel's Avatar
 
Join Date: Jul 2001
Location: Fort Collins, Colorado
Posts: 805
Likes: 0
Received 0 Likes on 0 Posts
HELP!!!! Non-sequential problem.

I tried the poor man non-sequential switch, using dontbearikki's site as a guide. I dont think that I missed any steps but I am only able to get 7PSI now and it builds very slowly. I wasnt hitting 7 until close to 5K RPM's. I also turned the sequential control off on my PFC. Anyone have any suggestions.
Old 06-09-02, 09:37 AM
  #3  
Full Member

 
Spencer's Avatar
 
Join Date: Oct 2001
Location: Orlando
Posts: 80
Likes: 0
Received 0 Likes on 0 Posts
I am thinking of going non-seq. Is there anything I need to do or check BEFORE doing this. I am not real familiar (somewhat) with the fd enginge being somewhat new to the rotary, I am good with hands, directions, and tools so I SHOULD be able to do this with no problem, RIGHT??????? Any help is appreciated in this quest for a better FD if possible I want to keep with the twin setup, but need more reliable power. Let me know. THANKS
Old 06-09-02, 12:40 PM
  #5  
Senior Member

 
Pressurized's Avatar
 
Join Date: Jul 2001
Location: Columbus, Ohio
Posts: 596
Likes: 0
Received 0 Likes on 0 Posts
Yeah, make sure you have the correct vacuum lines pulled and plugged. For PFC it should be:

Right solenoid 2 plugged(WG)
Left solenoid 2 connected(PC)

Take elec. connector from right(with dot or hash on it) and switch it to the connector on the left.

I am still trying to figure out mine as well. It seems no matter whether I use the pre-control to handle boost(like everyone says to do with the PFC) or if I switch it to the wastegate....it never changes, I always get the same thing. Kinda strange.
Old 06-09-02, 09:03 PM
  #6  
Altitude SUCKS!!!

Thread Starter
 
Dr Wankel's Avatar
 
Join Date: Jul 2001
Location: Fort Collins, Colorado
Posts: 805
Likes: 0
Received 0 Likes on 0 Posts
Ok I think that I figured out the problem. I did not switch the electrical connector from the solenoid on the rigth to the one on the left. I changed it back over to normal sequential last night so i could drive the car today so i will have to try to switch them back over again this week.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Snook
3rd Generation Specific (1993-2002)
17
02-27-21 02:54 PM
NotMrButts
1st Generation Specific (1979-1985)
25
02-10-18 06:36 PM
HalifaxFD
Canadian Forum
126
05-09-16 07:06 PM
vmerino
2nd Generation Specific (1986-1992)
0
09-05-15 11:26 AM



Quick Reply: HELP!!!! Non-sequential problem.



All times are GMT -5. The time now is 09:49 AM.