3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Help!!!

Thread Tools
 
Search this Thread
 
Old 10-08-02, 11:25 PM
  #1  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
Red face Help!!!



The other day I reconnected my airpump to the cat-convertor to try to pass emissions, and everything seemed to be fine. The car continued to run as normal, however, I shut it off, took it down off of the jack stands, fired it back up, and now it is running like crap. It seems like it is running really rich. I actually have a mist of fuel vapors coming out of the exhaust after shutting it off.

Initially it was idling really rough around 1500 rpm but it settled down and began to react somewhat normal again. Except for the smoking.

I began to trace down vacuum lines, and found nothing over the last day. Then, all of the sudden, I started it up again, and the smoking was gone, the idle was smoothe, and I thought the problem was gone.

Wrong I was!

Took it for a quick test drive around the block and it is backfiring like crazy when I let up off of the throttle. It also stumbles around 3-4000 RPM. (Similar to a fuel cut)

The car has the following installed:
-Power FC w/commander
-PF intercooler
-Pettit intake W/ K&N's
-Downpipe
-Highflow Cat
-Cat back exh.

I also just installed new plugs and cleaned my K&N airfilters. I only run high octane gas, and currently I have some octane booster in the tank as well. I am at a complete loss at this point and I am trying to remain positive that it is something simple.

Please help if you have had similar symptoms or any ideas I haven't tried yet.

Thanks in advance.
Old 10-09-02, 12:04 AM
  #2  
Tony Stewart Killer.

iTrader: (12)
 
Snook's Avatar
 
Join Date: Mar 2002
Location: London
Posts: 5,156
Likes: 0
Received 4 Likes on 4 Posts
wont not having the air pump connected mess up the main cat or a high flow cat?

sorry this is all I know
Old 10-09-02, 12:07 AM
  #3  
Rotary Freak

 
c00lduke's Avatar
 
Join Date: Jan 2002
Location: Overland Park, KS
Posts: 2,360
Likes: 0
Received 0 Likes on 0 Posts
have you tried resetting the ECU yet?
Old 10-09-02, 12:26 AM
  #4  
I Sold My Car 2 the Devil

 
wonder1and's Avatar
 
Join Date: Oct 2001
Location: Duncanville, Tx
Posts: 2,361
Likes: 0
Received 0 Likes on 0 Posts
Hey I ran into something similar w/ my car... run around in your PFC screens untill you see somthing named option 5 in there and see if it is selected or not if so deselect it and hopfully that will do it... you PFC probably did some CrAzY learning mode ****.... ps if your car is tuned don't reset the ***** or you'll be there for about 2 hours re-inputting the maps if you have them on paper... Hope this helps you can also pm me if you have more q's
Ryker
Old 10-09-02, 12:34 AM
  #5  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
Let me go check on the option 5 thing.
Old 10-09-02, 12:40 AM
  #6  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
The only thing that I see that mentions the word "option" is for the PIM Voltage settings. It has 5 choices:
normal
option1
option2
option3
option4

Is this what you are talking about?
Old 10-09-02, 12:44 AM
  #7  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
They all seem to have the same setting in each one also. 100%. Is there more to it than what I can see?
Old 10-09-02, 02:04 AM
  #8  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
does anyone know much about the power fc?
Old 10-09-02, 02:22 AM
  #9  
Senior Member

Thread Starter
iTrader: (13)
 
cohbra's Avatar
 
Join Date: Aug 2002
Location: Erie, Colorado
Posts: 609
Likes: 0
Received 5 Likes on 4 Posts
Well, anyone else that has a Power FC, and may have this problem, it was the option that was selected that gave me the problem.

When I was browsing through the settings, I didn't realize that the option that is highlighted, when you hit the previous button to back out of the PIM Voltage settings, would be the one that would take effect. I changed it back to normal and now my car runs great!!

Thanks wonder1and.

you saved me a lot of money, I was about to take it to the shop at $80 an hour.
Old 10-10-02, 03:50 PM
  #10  
I Sold My Car 2 the Devil

 
wonder1and's Avatar
 
Join Date: Oct 2001
Location: Duncanville, Tx
Posts: 2,361
Likes: 0
Received 0 Likes on 0 Posts
Glad I could help. Good luck w/ the PFC!
Ryker
[Dallas]




All times are GMT -5. The time now is 02:25 PM.