Fiber Clear reinforced hose question

Thread Tools
 
Search this Thread
 
Old Feb 17, 2010 | 07:03 PM
  #1  
KaiFD3S's Avatar
Thread Starter
SINFUL7
Tenured Member 15 Years
iTrader: (37)
 
Joined: Apr 2004
Posts: 6,574
Likes: 1
From: Alaska
Fiber Clear reinforced hose question

Just wondering if this type of hose is okay to use to bypass the coolant nipple at the waterpump housing, it is the clear hose that is fiber reinforced.
Reply
Old Feb 17, 2010 | 09:06 PM
  #2  
GoodfellaFD3S's Avatar
Original Gangster/Rotary!
Veteran: Army
Tenured Member: 25 Years
Liked
Loved
iTrader: (213)
 
Joined: Mar 2001
Posts: 30,804
Likes: 646
From: FL-->NJ/NYC again!
Kai, do you know the pressure rating? I wouldnt use anything other than legit coolant hose.
Reply
Old Feb 17, 2010 | 09:41 PM
  #3  
KaiFD3S's Avatar
Thread Starter
SINFUL7
Tenured Member 15 Years
iTrader: (37)
 
Joined: Apr 2004
Posts: 6,574
Likes: 1
From: Alaska
Yeah, decided to go to another store and get the regular hose, did not want to take the risk
Reply
Old Feb 17, 2010 | 10:09 PM
  #4  
Force13B's Avatar
No more G6
Tenured Member: 20 Years
iTrader: (19)
 
Joined: May 2005
Posts: 1,935
Likes: 1
From: Nipomo, California
Originally Posted by GoodfellaFD3S
Kai, do you know the pressure rating? I wouldnt use anything other than legit coolant hose.
http://flexpvc.com/PVCPipeSpecs.shtml
Seems to be 100psi for the 1/2inch and and 45psi for the 6inch but that's the non fiber reinforced so i'm sure that would be even higher

edit: looks to be a little over double
http://www.strongflex.com/PVC_Hose/F...rced_Hose.html
Reply
Old Feb 17, 2010 | 10:52 PM
  #5  
gracer7-rx7's Avatar
needs more track time
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (16)
 
Joined: Mar 2006
Posts: 9,766
Likes: 794
From: Bay Area CA
Don't forget to also check temp ratings of the hose as well as pressure ratings.
Reply
Old Feb 18, 2010 | 08:27 AM
  #6  
DaleClark's Avatar
RX-7 Bad Ass
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (56)
 
Joined: Jan 2002
Posts: 15,622
Likes: 2,725
From: Pensacola, FL
That type of hose is typically rather hard and thin-walled. I think you'd have problems getting it to seal right to the nipple, and over time the hose clamp would probably cut into the hose.

No need to reinvent the wheel on this one .

Dale
Reply
Old Feb 19, 2010 | 06:34 AM
  #7  
theorie's Avatar
AponOUT!?
Tenured Member 15 Years
iTrader: (31)
 
Joined: Nov 2002
Posts: 3,521
Likes: 13
From: Sarasota, FL
i think those hoses melt pretty easily. i used to use the clear fiber reinforced hoses for computer watercooling builds back in the early '00's...had a water pump fail once and the metal barb fitting got so hot it melted though the hose. installed a failsafe kill after that...lol
Reply
Old Feb 19, 2010 | 08:37 AM
  #8  
Herblenny's Avatar
DGRR 2017 4/26-4/30, 2017
Tenured Member 20 Years
iTrader: (13)
 
Joined: Nov 2001
Posts: 13,597
Likes: 6
From: Alabama
Originally Posted by gracer7-rx7
Don't forget to also check temp ratings of the hose as well as pressure ratings.
I agree.. if temp and pressure rating is ok, I don't see why not. I use some of these at work with over 150lbs of pressure (air) but never hot liquid under pressure.
Reply
Old Feb 19, 2010 | 09:09 AM
  #9  
GoodfellaFD3S's Avatar
Original Gangster/Rotary!
Veteran: Army
Tenured Member: 25 Years
Liked
Loved
iTrader: (213)
 
Joined: Mar 2001
Posts: 30,804
Likes: 646
From: FL-->NJ/NYC again!
Arrow

Originally Posted by DaleClark
That type of hose is typically rather hard and thin-walled. I think you'd have problems getting it to seal right to the nipple, and over time the hose clamp would probably cut into the hose.

No need to reinvent the wheel on this one .

Dale
+1

You're asking for problems using that stuff in an FD engine bay.
Reply
Old Feb 19, 2010 | 04:01 PM
  #10  
catch-22's Avatar
Rotary Enthusiast
Tenured Member 15 Years
iTrader: (2)
 
Joined: Jun 2006
Posts: 1,254
Likes: 0
From: Charlotte, NC
Friend used that stuff one time on his RB25 s14 and it was like goo after 5 min of driving.
Reply
Old Feb 19, 2010 | 04:03 PM
  #11  
Mahjik's Avatar
Mr. Links
Tenured Member 20 Years
iTrader: (1)
 
Joined: Aug 2001
Posts: 27,595
Likes: 43
From: Kansas City, MO
Originally Posted by KaiFD3S
Yeah, decided to go to another store and get the regular hose, did not want to take the risk
Gents, he already went a different route.
Reply
Old Feb 19, 2010 | 08:11 PM
  #12  
GoodfellaFD3S's Avatar
Original Gangster/Rotary!
Veteran: Army
Tenured Member: 25 Years
Liked
Loved
iTrader: (213)
 
Joined: Mar 2001
Posts: 30,804
Likes: 646
From: FL-->NJ/NYC again!
NOOOOOOO Don't Do it KAIIIIII
Reply
Old Feb 19, 2010 | 08:41 PM
  #13  
KaiFD3S's Avatar
Thread Starter
SINFUL7
Tenured Member 15 Years
iTrader: (37)
 
Joined: Apr 2004
Posts: 6,574
Likes: 1
From: Alaska
Originally Posted by KaiFD3S
Yeah, decided to go to another store and get the regular hose, did not want to take the risk

Shut this thread down please.....Thanks....
Reply