Fiber Clear reinforced hose question

Just wondering if this type of hose is okay to use to bypass the coolant nipple at the waterpump housing, it is the clear hose that is fiber reinforced.
Old 02-17-10, 09:06 PM
  #2  
Original Gangster/Rotary!


iTrader: (213)
 
GoodfellaFD3S's Avatar
 
Join Date: Mar 2001
Location: FL-->NJ/NYC again!
Posts: 30,525
Received 538 Likes on 325 Posts
Kai, do you know the pressure rating? I wouldnt use anything other than legit coolant hose.
Old 02-17-10, 09:41 PM
  #3  
SINFUL7

Thread Starter
iTrader: (37)
 
KaiFD3S's Avatar
 
Join Date: Apr 2004
Location: Alaska
Posts: 6,574
Received 1 Like on 1 Post
Yeah, decided to go to another store and get the regular hose, did not want to take the risk
Old 02-17-10, 10:09 PM
  #4  
No more G6

iTrader: (19)
 
Force13B's Avatar
 
Join Date: May 2005
Location: Nipomo, California
Posts: 1,935
Likes: 0
Received 1 Like on 1 Post
Originally Posted by GoodfellaFD3S
Kai, do you know the pressure rating? I wouldnt use anything other than legit coolant hose.
http://flexpvc.com/PVCPipeSpecs.shtml
Seems to be 100psi for the 1/2inch and and 45psi for the 6inch but that's the non fiber reinforced so i'm sure that would be even higher

edit: looks to be a little over double
http://www.strongflex.com/PVC_Hose/F...rced_Hose.html
Old 02-17-10, 10:52 PM
  #5  
needs more track time

iTrader: (16)
 
gracer7-rx7's Avatar
 
Join Date: Mar 2006
Location: Bay Area CA
Posts: 9,178
Received 506 Likes on 348 Posts
Don't forget to also check temp ratings of the hose as well as pressure ratings.
Old 02-18-10, 08:27 AM
  #6  
RX-7 Bad Ass

iTrader: (55)
 
DaleClark's Avatar
 
Join Date: Jan 2002
Location: Pensacola, FL
Posts: 15,399
Received 2,437 Likes on 1,508 Posts
That type of hose is typically rather hard and thin-walled. I think you'd have problems getting it to seal right to the nipple, and over time the hose clamp would probably cut into the hose.

No need to reinvent the wheel on this one .

Dale
Old 02-19-10, 06:34 AM
  #7  
AponOUT!?

iTrader: (31)
 
theorie's Avatar
 
Join Date: Nov 2002
Location: Sarasota, FL
Posts: 3,521
Likes: 0
Received 13 Likes on 9 Posts
i think those hoses melt pretty easily. i used to use the clear fiber reinforced hoses for computer watercooling builds back in the early '00's...had a water pump fail once and the metal barb fitting got so hot it melted though the hose. installed a failsafe kill after that...lol
Old 02-19-10, 08:37 AM
  #8  
DGRR 2017 4/26-4/30, 2017

iTrader: (13)
 
Herblenny's Avatar
 
Join Date: Nov 2001
Location: Alabama
Posts: 13,597
Likes: 0
Received 5 Likes on 4 Posts
Originally Posted by gracer7-rx7
Don't forget to also check temp ratings of the hose as well as pressure ratings.
I agree.. if temp and pressure rating is ok, I don't see why not. I use some of these at work with over 150lbs of pressure (air) but never hot liquid under pressure.
Old 02-19-10, 09:09 AM
  #9  
Original Gangster/Rotary!


iTrader: (213)
 
GoodfellaFD3S's Avatar
 
Join Date: Mar 2001
Location: FL-->NJ/NYC again!
Posts: 30,525
Received 538 Likes on 325 Posts
Arrow

Originally Posted by DaleClark
That type of hose is typically rather hard and thin-walled. I think you'd have problems getting it to seal right to the nipple, and over time the hose clamp would probably cut into the hose.

No need to reinvent the wheel on this one .

Dale
+1

You're asking for problems using that stuff in an FD engine bay.
Old 02-19-10, 04:01 PM
  #10  
Rotary Enthusiast

iTrader: (2)
 
catch-22's Avatar
 
Join Date: Jun 2006
Location: Charlotte, NC
Posts: 1,254
Likes: 0
Received 0 Likes on 0 Posts
Friend used that stuff one time on his RB25 s14 and it was like goo after 5 min of driving.
Old 02-19-10, 04:03 PM
  #11  
Mr. Links

iTrader: (1)
 
Mahjik's Avatar
 
Join Date: Aug 2001
Location: Kansas City, MO
Posts: 27,595
Received 40 Likes on 26 Posts
Originally Posted by KaiFD3S
Yeah, decided to go to another store and get the regular hose, did not want to take the risk
Gents, he already went a different route.
Old 02-19-10, 08:11 PM
  #12  
Original Gangster/Rotary!


iTrader: (213)
 
GoodfellaFD3S's Avatar
 
Join Date: Mar 2001
Location: FL-->NJ/NYC again!
Posts: 30,525
Received 538 Likes on 325 Posts
NOOOOOOO Don't Do it KAIIIIII
Old 02-19-10, 08:41 PM
  #13  
SINFUL7

Thread Starter
iTrader: (37)
 
KaiFD3S's Avatar
 
Join Date: Apr 2004
Location: Alaska
Posts: 6,574
Received 1 Like on 1 Post
Originally Posted by KaiFD3S
Yeah, decided to go to another store and get the regular hose, did not want to take the risk

Shut this thread down please.....Thanks....