3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Blitz FMIC + Fluidyne + R1 package?

Thread Tools
 
Search this Thread
 
Old 06-19-02, 08:55 PM
  #1  
It has begun

Thread Starter
iTrader: (20)
 
lane_change's Avatar
 
Join Date: Feb 2002
Location: Houston, TX
Posts: 3,393
Received 17 Likes on 5 Posts
Question Blitz FMIC + Fluidyne + R1 package?

Does anyone know if I can install a Fluidyne Radiator into my R1 with a Blitz FMIC? My stock one was a tight squeeze so I am not sure if the Fluidyne will fit. I have seen it installed in a Touring model but they don't have that damn oil line in the way. My car has been down now for 5 weeks and I finally got to take it back out yesterday with no problems and then today at my shop the bastard started blowing coolant everywhere. So now my car is down again until I get a new radiator. I would rather go Fluidyne but stock may be my only chance. Any input would be great. Thanks, Scott
Old 06-19-02, 09:03 PM
  #2  
Senior Member

 
IgoSlow's Avatar
 
Join Date: Nov 2001
Location: Houston
Posts: 520
Likes: 0
Received 0 Likes on 0 Posts
should fit... i have the sr motorsports ult. radiator and blitz front mount.. eazy fit and install.. I even manage to get teh stock fans to fit...=)
Old 06-19-02, 10:17 PM
  #3  
Tequila? ..it's like beer

iTrader: (1)
 
NewbernD's Avatar
 
Join Date: Mar 2001
Location: Woodbine, MD
Posts: 1,124
Likes: 0
Received 0 Likes on 0 Posts
We're in the same boat.. I've got a koyo which is another 1/2" thicker, and after staring at that big oil crossover line for an hour or two, I'm running around with the stock radiator. Someone posted that they managed to fit it together, but he had to pull the cross-member (which I currently use to mount my ast & battery to) and bend the oil line. With the stock rad, though, the fans are RIGHT up on that oil line.. gonna have to find an inch and a bit somewhere in there.
Old 06-25-02, 09:41 PM
  #4  
Senior Member

 
IgoSlow's Avatar
 
Join Date: Nov 2001
Location: Houston
Posts: 520
Likes: 0
Received 0 Likes on 0 Posts
Oh yeah i did pull out the crossmember. That only because i wanted to use stock fans.. You can get slimmer fans and keep your crossmember.
Old 06-26-02, 01:17 AM
  #5  
It has begun

Thread Starter
iTrader: (20)
 
lane_change's Avatar
 
Join Date: Feb 2002
Location: Houston, TX
Posts: 3,393
Received 17 Likes on 5 Posts
Did you have an R1? What did you do to go around the oil line?
Old 06-26-02, 06:14 PM
  #6  
Senior Member

 
IgoSlow's Avatar
 
Join Date: Nov 2001
Location: Houston
Posts: 520
Likes: 0
Received 0 Likes on 0 Posts
no i have base model.. I plan to put dual oil coolers and just plan to get long lines run underneath all that stuff.
Old 06-26-02, 08:31 PM
  #7  
It has begun

Thread Starter
iTrader: (20)
 
lane_change's Avatar
 
Join Date: Feb 2002
Location: Houston, TX
Posts: 3,393
Received 17 Likes on 5 Posts
I removed the crossmember today and cut the battery attachment piece off and attached that small piece back on. It fit in there fine with a little muscle to get the oil lines pushed back far enough so now I have the Blitz FMIC, AC Condensor, and the Fluidyne Radiator in my R1. Thanks God.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
zyph3r
Canadian Forum
10
09-16-18 07:14 PM



Quick Reply: Blitz FMIC + Fluidyne + R1 package?



All times are GMT -5. The time now is 06:50 AM.