3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

attn: fd's w/ streetported motors

Thread Tools
 
Search this Thread
 
Old 01-02-03, 01:26 PM
  #1  
Rotary Freak

Thread Starter
 
Join Date: Jan 2002
Location: l.a.
Posts: 1,640
Likes: 0
Received 0 Likes on 0 Posts
attn: fd's w/ streetported motors

what fuel management do you guys use? out of curiousity has anyone just used the stock ecu w/ a mild street port?
Old 01-02-03, 01:27 PM
  #2  
Rotary Enthusiast

 
Nameless's Avatar
 
Join Date: Jul 2001
Location: Nashville, TN
Posts: 1,087
Likes: 0
Received 0 Likes on 0 Posts
I do, no problems (so far). But am looking into a PFC or Haltech this coming year.
Old 01-02-03, 01:40 PM
  #3  
Part out my Car

 
mmonaco's Avatar
 
Join Date: Feb 2002
Location: Denver, Colorado
Posts: 1,762
Likes: 0
Received 0 Likes on 0 Posts
I want to know this!! Who the hell has blown there motor with a streetport and the stock ECU? Everyone says dont do it yet i havent heard of anyone blowing up there motor! WtF maybe i havent been around long enough!!
Old 01-02-03, 01:42 PM
  #4  
Part out my Car

 
mmonaco's Avatar
 
Join Date: Feb 2002
Location: Denver, Colorado
Posts: 1,762
Likes: 0
Received 0 Likes on 0 Posts
Ohh ya and i am about to use a haltech!! I wouls say you dont need one if thats your only mod, I boosted my engine and a/f looked fine. So i dont know i just bought one to be safe but now im thinking i didnt need it so soos, ohh well ill jst get some more mods!!
Old 01-02-03, 05:26 PM
  #5  
Senior Member

 
efiniracing's Avatar
 
Join Date: Mar 2001
Location: Norcross,Ga,USA
Posts: 554
Likes: 0
Received 0 Likes on 0 Posts
I have a street port and I've been using the old Efi unit for a while now. 35,000 mile running 17lbs of boost w/ no problems. only thing is my stock turbos can't hang. starting to take a long time to spool. Need new turbos
Old 01-02-03, 05:50 PM
  #6  
Banned. I got OWNED!!!
iTrader: (1)
 
yzf-r1's Avatar
 
Join Date: Dec 2001
Location: Charlotte
Posts: 552
Likes: 0
Received 0 Likes on 0 Posts
I have a street port and I've been using the old Efi unit for a while now. 35,000 mile running 17lbs of boost w/ no problems

Old 01-02-03, 06:21 PM
  #7  
Tony Stewart Killer.

iTrader: (12)
 
Snook's Avatar
 
Join Date: Mar 2002
Location: London
Posts: 5,156
Likes: 0
Received 4 Likes on 4 Posts
series I would go with a PFC with a streetport
I'm thinking thats why my motor ran lean
Old 01-02-03, 06:42 PM
  #8  
Racing is Life.....

 
Beast From The East's Avatar
 
Join Date: Nov 2001
Location: Northern California
Posts: 576
Likes: 0
Received 0 Likes on 0 Posts
I'm with YZF-r1 on this one

Originally posted by efiniracing
I have a street port and I've been using the old Efi unit for a while now. 35,000 mile running 17lbs of boost w/ no problems. only thing is my stock turbos can't hang. starting to take a long time to spool. Need new turbos
Present ..... flag



[Kirk}Scotty, I need more BS...
[Mr. Scott] I'm given' 'er all she gott, Cap'n'. The meter is pegged:




This motor would have gone boom a long time ago using the stock ecu at those levels......
Old 01-02-03, 06:52 PM
  #9  
Part out my Car

 
mmonaco's Avatar
 
Join Date: Feb 2002
Location: Denver, Colorado
Posts: 1,762
Likes: 0
Received 0 Likes on 0 Posts
I dont even think your injectors will handle 17psi of fuel!!
Old 01-02-03, 07:02 PM
  #10  
Banned. I got OWNED!!!
iTrader: (1)
 
yzf-r1's Avatar
 
Join Date: Dec 2001
Location: Charlotte
Posts: 552
Likes: 0
Received 0 Likes on 0 Posts
I've been wondering also if it's safe to run my Pettit Unlimited with a street ported engine, or if I should go with a PFC

there is another guy on here making about 340 at the wheels with a pettit computer and a ported motor....he flogs his car at the track routinely, so it can be done

when I get my ported engine back I plan to run the Pettit with a upgraded fuel pump and flowed stock injectors at no more than 13 psi.....if I want to go above that at some point in the future I will get the PFC and big injectors, but if I get around 330 at the wheels I'll be happy for now....I've blown enough cash lately
Old 01-02-03, 07:18 PM
  #11  
0 lbs of boost

iTrader: (1)
 
turbogarrett's Avatar
 
Join Date: May 2002
Location: wisconsin
Posts: 1,261
Likes: 0
Received 1 Like on 1 Post
i drove mine for 3000 miles with a stock ecu, now have the pettit unlimited ecu. just keep the boost down and you'll be fine.
Old 01-02-03, 09:44 PM
  #12  
Lives on the Forum

 
SleepR1's Avatar
 
Join Date: Sep 2001
Location: IN
Posts: 6,131
Likes: 0
Received 2 Likes on 2 Posts
From what I've read ...

the stock ECU cannot retard the ignition to complement the increased crank angles of enlarged intake and exhaust ports; to truly take advantage of the port job.

AFIK the only way to retard the ignition is to use a programmable ECU and change the ignition maps. Even the Apex Power FC's base maps need to be modified; the PFC's ignition maps are too advanced for a motor with enlarged intake/exhaust ports.

Depending on your mods, you can probably get away with an unlimited Pettit ECU, but why go half way when you go all the way with a fully programmable ECU like a Haltech or Apex Power FC??

FWIW, I've read of one guy's Atkins ported motor blown with a stock IC, RB intake duct, Japan spec twins (13 psi), DP/High-Flo Cat/RB Dual, Walbro fuel pump, Pettit unlimited ECU.

The root cause was a lean AFR and oil starvation, AFIK.

Last edited by SleepR1; 01-02-03 at 09:51 PM.
Old 01-02-03, 09:52 PM
  #13  
WTB** Very Low Miles 94-95

 
artguy's Avatar
 
Join Date: Jul 2001
Location: Tejas
Posts: 3,298
Likes: 0
Received 0 Likes on 0 Posts
my car ran fine on a streetport with the stock ecu..intake..dp..and catback...

when i added more fuel via a gforce ecu the car took off...it was not getting enough fuel to get great performance.


the car will run fine ...but it wont wake up until you tune it.


j

ps...dont buy any of the junk ecus...get a pfc at the very least...a haltech and motec as the step above that.
Old 01-02-03, 10:41 PM
  #14  
Rotary Enthusiast

 
ArchangelX's Avatar
 
Join Date: Nov 2002
Location: Oahu, Hawaii
Posts: 792
Likes: 0
Received 0 Likes on 0 Posts
Funny..I thought the PFC was a step above the haltech and motec.
Old 01-02-03, 11:07 PM
  #15  
Banned. I got OWNED!!!
iTrader: (1)
 
yzf-r1's Avatar
 
Join Date: Dec 2001
Location: Charlotte
Posts: 552
Likes: 0
Received 0 Likes on 0 Posts
I know plenty of people running a pettit ECU with a ported engine, full exhaust and big IC, and the car rips, you just can't run more than 13

FWIW, I've read of one guy's Atkins ported motor blown with a stock IC, RB intake duct, Japan spec twins (13 psi), DP/High-Flo Cat/RB Dual, Walbro fuel pump, Pettit unlimited ECU.

the stock IC is what killed it.....trust me....that thing heat soaks when you idle the engine too long
Old 01-02-03, 11:11 PM
  #16  
Banned. I got OWNED!!!
iTrader: (1)
 
yzf-r1's Avatar
 
Join Date: Dec 2001
Location: Charlotte
Posts: 552
Likes: 0
Received 0 Likes on 0 Posts
but why go half way when you go all the way with a fully programmable ECU like a Haltech or Apex Power FC??

because some people don't have money coming out of their ears, ha
Old 01-02-03, 11:39 PM
  #17  
Senior Member

 
TomsRX7's Avatar
 
Join Date: Sep 2001
Location: California
Posts: 373
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by yzf-r1
I have a street port and I've been using the old Efi unit for a while now. 35,000 mile running 17lbs of boost w/ no problems

I'm with YZF-R1
Old 01-02-03, 11:45 PM
  #18  
Rotary Enthusiast

 
RX7Elmo's Avatar
 
Join Date: Jul 2002
Location: CA
Posts: 896
Likes: 0
Received 0 Likes on 0 Posts
I think it i possible to run 17psi and a streetport on the EFI unit. Rikki Got over 350rwhp on his ported motor using the EFI unit. Of course he wasn't hitting 17psi. But with bigger injectors, the EFI unit can hang. Of course the PFC or AEM or haltech, motec is better

Danny
Old 01-03-03, 12:35 AM
  #19  
Senior Member

 
Join Date: Nov 2001
Location: Nowhere
Posts: 318
Likes: 0
Received 0 Likes on 0 Posts
so ignition timing should be retarded with street port?
how many dgree at the top end?
Old 01-03-03, 10:55 AM
  #20  
call me Smokie Smokerson

 
r0t0r-rooter's Avatar
 
Join Date: Aug 2002
Location: Southern California
Posts: 1,665
Likes: 0
Received 0 Likes on 0 Posts
More importantly, what does AFIK mean?
Old 01-03-03, 11:25 AM
  #21  
Lives on the Forum

 
SleepR1's Avatar
 
Join Date: Sep 2001
Location: IN
Posts: 6,131
Likes: 0
Received 2 Likes on 2 Posts
Yes, specifically the trailing spark. Don't know how many degrees. That's what I'm paying my engine builder to know

Originally posted by Redrotor
so ignition timing should be retarded with street port?
how many dgree at the top end?
Old 01-03-03, 11:26 AM
  #22  
Lives on the Forum

 
SleepR1's Avatar
 
Join Date: Sep 2001
Location: IN
Posts: 6,131
Likes: 0
Received 2 Likes on 2 Posts
AFIK

As Far As I Know

Originally posted by r0t0r-rooter
More importantly, what does AFIK mean?
Old 01-03-03, 11:28 AM
  #23  
Lives on the Forum

 
SleepR1's Avatar
 
Join Date: Sep 2001
Location: IN
Posts: 6,131
Likes: 0
Received 2 Likes on 2 Posts
Exactly. The extra money you put into street porting won't be realized until you retard the ignition ie, delay the spark until all the intake air as been sucked into the combustion chamber from the enlarged ports

Originally posted by artguy
the car will run fine ...but it wont wake up until you tune it.
Old 01-03-03, 12:12 PM
  #24  
Lives on the Forum

iTrader: (9)
 
ptrhahn's Avatar
 
Join Date: Feb 2002
Location: Arlington, VA
Posts: 9,027
Received 500 Likes on 274 Posts
You COULD run a streetport witrh a stock ECU, but you'd have to have minimal other mods which would really negate the port.

You shouldn't run a stock ECU even if you had all the bolt-ons and no port. Don't be a cheapskate, and try to buy all the "power" mods and no safety mods.

FWIW, i have all bolt ons (hiFlow cat) and a KDR streeport. I've run both the EFI and PFC with virtually no problems up to 13 psi... only fuel mod is a supra FP. I'm going with 1300 cc injectors however because my duty cycles @ 12 psi are around 95%.
Old 01-03-03, 01:35 PM
  #25  
Senior Member

 
bureau_c's Avatar
 
Join Date: Oct 2002
Location: South Florida
Posts: 617
Likes: 0
Received 0 Likes on 0 Posts
I was running a Pettit Unlimited with a mild streetport, downpipe and intake. It was plenty rich and ran very nicely..actually, I suspect it was a little too rich, but better safe than sorry. Anyway, my Pettit ECU developed a problem turning on the AC (not that I need it right now except when it rains) so I replaced it with a stock ECU while I try to fix it. It doesn't run as well, but its OK...I don't get on it much, but when I do it is still quite rich. I actually find that curious, but its true...even with the stock ECU I am not running even close to lean at WOT.

jds

Originally posted by SERIES7


I've been wondering also if it's safe to run my Pettit Unlimited with a street ported engine, or if I should go with a PFC