sorry i tried searching and there is a million threads on the omp but most are leaks and replacing lines which do not help. my 1st question is my omp nozzels are capped and have been this way for the past two years but i didn't know until now because this rebuild i'm doing my self, i read that they need a constant vac. source so does this mean that the omp hasn't been working? i have a pfc so it wouldn't have gone into limp mode. should i have been running pre-mix and if i should i would have been nice of the shop who capped them to tell me. 2nd question is when i installed the omp to the front cover today there is a small gap but all the bolts line up so i don't see how i could have installed it wrong? is this normal. thanks
Attached Thumbnails 2 omp questions-omp1.jpg   2 omp questions-omp2.jpg  
Old 02-25-08, 05:45 PM
  #2  
rebreaking things

 
CMonakar's Avatar
 
Join Date: Apr 2006
Location: Manhattan
Posts: 866
Likes: 0
Received 0 Likes on 0 Posts
1. The nozzles need fresh air not vacuum. If they are capped you may get more (not less) oil injected under some conditions. The PFC only monitors the position of the oil metering pump's stepper motor. It does not directly monitor the amount of oil metering into the motor.

2. That's normal.
Old 02-25-08, 06:20 PM
  #3  
Lets Go Hokies!

iTrader: (5)
 
afterburn27's Avatar
 
Join Date: Aug 2001
Location: Greenville, SC
Posts: 1,727
Likes: 0
Received 4 Likes on 3 Posts
Originally Posted by CMonakar
1. The nozzles need fresh air not vacuum. If they are capped you may get more (not less) oil injected under some conditions. The PFC only monitors the position of the oil metering pump's stepper motor. It does not directly monitor the amount of oil metering into the motor.

2. That's normal.
+1
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Jeff20B
1st Generation Specific (1979-1985)
73
09-16-18 07:16 PM
cewrx7r1
3rd Generation Specific (1993-2002)
15
08-06-18 11:41 AM
Blk 93
3rd Generation Specific (1993-2002)
11
09-09-15 10:56 AM
rotor_veux
2nd Generation Specific (1986-1992)
5
09-03-15 07:10 PM



Quick Reply: 2 omp questions



All times are GMT -5. The time now is 09:42 AM.