Fd3s twins and factory boost control

Thread Tools
 
Search this Thread
 
Old 12-14-21, 08:24 PM
  #1  
Full Member
Thread Starter
iTrader: (1)
 
gitkrunk's Avatar
 
Join Date: Sep 2020
Location: VA
Posts: 51
Likes: 0
Received 4 Likes on 4 Posts
Fd3s twins and factory boost control

So I got the power fc installed new BNR stage ones and a upgraded remote solenoid pack from a member here and all upgraded fueling and ignition mods, I got good factory boost and transition. I tried to up the boost on the power FC and don’t see change. Do I need to install this apexi boost controller? Or should I be able to turn up the boost on the factory pre control and wastegate solenoids?
Old 12-15-21, 06:47 AM
  #2  
Full Member
Thread Starter
iTrader: (1)
 
gitkrunk's Avatar
 
Join Date: Sep 2020
Location: VA
Posts: 51
Likes: 0
Received 4 Likes on 4 Posts
Also I don’t have the pills installed
Old 12-15-21, 08:35 AM
  #3  
RX-7 Bad Ass

iTrader: (55)
 
DaleClark's Avatar
 
Join Date: Jan 2002
Location: Pensacola, FL
Posts: 15,399
Received 2,438 Likes on 1,509 Posts
Originally Posted by gitkrunk
Also I don’t have the pills installed
Bingo. You need the pills. Factory boost control has to have the pills to work properly.

You may want to get a good electronic boost controller.

Dale
Old 12-15-21, 08:47 AM
  #4  
Full Member
Thread Starter
iTrader: (1)
 
gitkrunk's Avatar
 
Join Date: Sep 2020
Location: VA
Posts: 51
Likes: 0
Received 4 Likes on 4 Posts
Thanks, I got the apexi one I just wanted to make sure everything was working right and adjusting before throwing it in. Seeing some pictures it looks like it’s best to cap one side of each actuator, T off both actuator and run to the controller
Old 12-25-21, 08:26 PM
  #5  
Full Member
Thread Starter
iTrader: (1)
 
gitkrunk's Avatar
 
Join Date: Sep 2020
Location: VA
Posts: 51
Likes: 0
Received 4 Likes on 4 Posts
Dropped in some NOS jets .059in for first turbo pellet and .064 for second turbo pellet. Building 10psi on first turbo and 14 psi on second turbo. I’m raise the boost number and duty cycle on the power fc but not building anymore on the first turbo. Do I need to reduce the pellet size more ?
Old 12-26-21, 09:50 AM
  #6  
Moderator

iTrader: (3)
 
j9fd3s's Avatar
 
Join Date: Mar 2001
Location: https://www2.mazda.com/en/100th/
Posts: 30,841
Received 2,605 Likes on 1,848 Posts
Originally Posted by gitkrunk
Dropped in some NOS jets .059in for first turbo pellet and .064 for second turbo pellet. Building 10psi on first turbo and 14 psi on second turbo. I’m raise the boost number and duty cycle on the power fc but not building anymore on the first turbo. Do I need to reduce the pellet size more ?
you could try that. it would give the solenoid more authority
Old 12-26-21, 10:08 AM
  #7  
Full Member
Thread Starter
iTrader: (1)
 
gitkrunk's Avatar
 
Join Date: Sep 2020
Location: VA
Posts: 51
Likes: 0
Received 4 Likes on 4 Posts
Awesome will give it a try. Was wondering they the actuator has 2 inputs, I get the one form the solenoid that goes to it and let’s it control how much pressure is out to it, why does the turbo output connect to the other side of it ? Couldn’t I just cap those off and let solenoid only control it ? Or is a safety feature ?
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
RTS3GEN
Power FC Forum
8
03-24-11 04:02 PM
shinchrono
Power FC Forum
6
12-14-05 12:10 PM
mikejenkins
Power FC Forum
3
12-12-03 11:28 PM
ApexRX7
Power FC Forum
20
03-05-03 11:31 AM
colin
Power FC Forum
2
12-29-02 05:07 PM



Quick Reply: Fd3s twins and factory boost control



All times are GMT -5. The time now is 12:46 AM.