2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

reted's parallel fuel rail diagram?

Thread Tools
 
Search this Thread
 
Old 09-04-03, 10:35 AM
  #26  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
Originally posted by Ridge Tech
I've got a S4 TII I guess thats why it looked forigen to me. Are they Alum. like the S4's?
The S5 rails are welded tubular steel, or welded brass, rather than the nice cast aluminum rails on the S4.
Old 09-04-03, 10:38 AM
  #27  
What Subscription?

 
banzaitoyota's Avatar
 
Join Date: Apr 2001
Location: Aiken SC USA
Posts: 5,926
Likes: 0
Received 0 Likes on 0 Posts
Another reson not to particuliarly care for S5's!!! How bout those ball joints!
Old 09-04-03, 10:44 AM
  #28  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
Originally posted by banzaitoyota
Another reson not to particuliarly care for S5's!!! How bout those ball joints!
LOL....

Ah, Mazda just did some cheapo things on the S5 cars, trying to save a buck or two.
Old 09-04-03, 05:02 PM
  #29  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
so what can i do to the s5 rails to make them flow better asuming that they wont flow enough for 1200 secondaries? can i just use plain ole fuel line and run them in parrallel to a aftermarket fpr? buty useing the factory in and out ?
Old 09-04-03, 06:06 PM
  #30  
Rotary Enthusiast

 
ERAUMAZDA's Avatar
 
Join Date: Sep 2002
Location: Daytona beach
Posts: 1,351
Likes: 0
Received 0 Likes on 0 Posts
buy one from KRD
Old 09-06-03, 11:33 AM
  #31  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
well im gonna convet so s4 rails. so tell me whats the point behind two y splitters?
Old 09-07-03, 02:44 AM
  #32  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
bump
Old 09-09-03, 05:03 PM
  #33  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
bump
Old 09-10-03, 05:03 AM
  #34  
Lives on the Forum

 
RETed's Avatar
 
Join Date: Feb 2001
Location: n
Posts: 26,664
Likes: 0
Received 16 Likes on 15 Posts
Man, I didn't know all this stuff was going to generate this much interest.

Sorry to the Kouki guys, as the diagram is for Zenki fuel rails.&nbsp If you want to keep your Kouki fuel rails (they are much larger ID), you need to cut off the ends and weld on steel AN male fittings to match up with the AN hardware.&nbsp The rest of the diagram should work for you - in fact, it might be cheaper to cut and weld steel male AN's than to go with the aluminum adapters for the Zenki fuel rails.

Hey Crusader_9x, you only need one splitter, as the aftermarket FPR are usually dual inlet design.


-Ted
Old 11-08-03, 10:39 AM
  #35  
Rotary Enthusiast

 
Impreza2RX7's Avatar
 
Join Date: Jun 2003
Location: Millville, NJ
Posts: 1,424
Likes: 0
Received 0 Likes on 0 Posts
Where's the write up for this Ted? I have my manifolds off right now since I ripped out the vacuum rack, so I might as well do this since I'm putting in 4 720s, a adjustable fpr, a T04B, and a boatload of other stuff over the winter.
Old 11-22-03, 04:07 PM
  #36  
Full Member

 
TPDNRX7's Avatar
 
Join Date: Feb 2001
Location: Central New York
Posts: 152
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by Crusader_9x
well im gonna convet so s4 rails. so tell me whats the point behind two y splitters?
I would like to know this as well.
Old 12-19-03, 06:54 PM
  #37  
Rotary Enthusiast


iTrader: (5)
 
Net Seven's Avatar
 
Join Date: Apr 2002
Location: Mesa, AZ
Posts: 1,470
Received 15 Likes on 11 Posts
Can I use the stock s4 NA fuel rails for my TII? Beucase I have an s5 TII engine, and I have some extra s4 NA engines with fuel rails.. so is the s4 na and TII fuel rails different?
Old 12-20-03, 11:28 AM
  #38  
Cell Broadband Engine

iTrader: (1)
 
TrboRty's Avatar
 
Join Date: Aug 2003
Location: USA
Posts: 515
Likes: 0
Received 0 Likes on 0 Posts
does anybody know if you can run the braided hoses with this setup?
Old 12-20-03, 12:24 PM
  #39  
IAN
Rotary Reborn!

iTrader: (3)
 
IAN's Avatar
 
Join Date: Mar 2001
Location: Canada
Posts: 5,284
Received 9 Likes on 6 Posts
Yes. Most people do use braided lines. Regular lines without the AN fittings are cheaper.

I have opted to use earls fittings and SS braided lines. Now all I have to do is install them.

I think the NA and Turbo S4's use the same fuel rails. I might be wrong.
Old 12-20-03, 02:25 PM
  #40  
Cell Broadband Engine

iTrader: (1)
 
TrboRty's Avatar
 
Join Date: Aug 2003
Location: USA
Posts: 515
Likes: 0
Received 0 Likes on 0 Posts
do you have to cut the ends off the stock primary fuel rail for the -an fittings? for a s4 fuel rail that is.
Old 12-21-03, 07:27 AM
  #41  
IAN
Rotary Reborn!

iTrader: (3)
 
IAN's Avatar
 
Join Date: Mar 2001
Location: Canada
Posts: 5,284
Received 9 Likes on 6 Posts
I just cut the little fuel line stop off. (Bracket that kept the stock lines from twisting. Very easy with a hack saw. The AN fitting just screwed on.

Thats all the easy stuff. For me was fitting in the 1600cc injectors.
Old 12-21-03, 12:03 PM
  #42  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
when i didi this i switched to s4 turbo rails but i have no clue if s4 na rails are the same or not. u ca nuse the socketless hose(non braided) it holds up to plenty of heat and pressure and is easy as hell to install. oh yeah its alot cheaper to. thats what i used.
Old 12-28-03, 05:33 AM
  #43  
Moderator

iTrader: (1)
 
silverrotor's Avatar
 
Join Date: Mar 2002
Location: Toronto, Corporate Canada
Posts: 7,592
Received 5 Likes on 5 Posts
I have 2 very simple questions.

- What Implications will I have If I opt to use s4 TII Rails on my s5 TII, as far as fitting them on? I remember something like they are not direct bolt ons.

- How are you connecting the braided line to the Fuel Filter and return line?

Last edited by silverrotor; 12-28-03 at 05:38 AM.
Old 12-28-03, 05:37 AM
  #44  
Rotary Enthusiast

iTrader: (9)
 
boosted1205's Avatar
 
Join Date: Jun 2003
Location: west
Posts: 1,191
Likes: 0
Received 0 Likes on 0 Posts
Not sure about the first question but to the second question is use a hard line adapter. They sell them in -6.
I wouldn't use clamps especially on s/s lines . I've seen a few do this and it's scary.
Or, you can use the Aeroquip Push Lock hoses. They use AN barbed fittings and I assume you can use clamps on these for hard lines.

Last edited by boosted1205; 12-28-03 at 06:00 AM.
Old 12-28-03, 02:14 PM
  #45  
Rotary Enthusiast

 
ponykiller's Avatar
 
Join Date: Aug 2001
Location: KC
Posts: 819
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by silverrotor
I have 2 very simple questions.

- What Implications will I have If I opt to use s4 TII Rails on my s5 TII, as far as fitting them on? I remember something like they are not direct bolt ons.

- How are you connecting the braided line to the Fuel Filter and return line?

S4 rails on an S5 motor is just a simple bolt on. I had zero problems using the S4 rails on my engine. No modifications are necesary.

I can only tell you about what I am doing for that: I am running socketless -6AN adapters with non-braided lines. At the stock delivery and return lines (fuel filter included) the aeroquip hose (-6 AN socketless, non-braided) just fits over the stock metal fuel lines. I then used two stock screw clamps per hose to hold the aeroquip line to the metal fuel lines.

Hope this helps
Old 04-01-04, 04:37 PM
  #46  
Rotary Enthusiast

 
Crusader_9x's Avatar
 
Join Date: Sep 2001
Location: Woodstock, GA
Posts: 1,384
Received 0 Likes on 0 Posts
i got the same setup as ponykiller and its working great. i got the socketless stuff hoseclamped to the factory feed and return lines
Old 06-09-04, 02:40 PM
  #47  
I AM A THIEF!! READ THE FEEDBACK SECTION!

 
MazdaRx7Racer4Life's Avatar
 
Join Date: Aug 2002
Location: Miami, FL
Posts: 86
Likes: 0
Received 0 Likes on 0 Posts
Is it alright to do this setup with fuel lines instead of braided lines? I already have ALOT of high pressure fuel lines and don't want to spend money on the an parts.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
astrum
2nd Generation Specific (1986-1992)
24
11-15-17 08:44 AM



Quick Reply: reted's parallel fuel rail diagram?



All times are GMT -5. The time now is 10:43 PM.