relays? Does anyone know whay type of relay I need?

I am trying to open and close a circuit with a pulse not a constant energy source does a relay exist to do this or do I need something different?

The pulse would be from a keyless entry system keypad.
Old 06-29-06, 07:23 PM
  #2  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
What are you really trying to do???

If the keyless has a pulse, you already have a signal to activate a relay
Old 06-29-06, 07:32 PM
  #3  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
yes most of the relays i have seen require constant power to hold the circuit closed I cannot provide constant power nor can I find a relay that operates off a pulse.

By the way I was hoping and praying that you would answer. Thanks

Oops didnt answer the question. I am trying to allow and disallow power to given components

Haltech
switch panel
starter

Last edited by tinvestor; 06-29-06 at 07:34 PM.
Old 06-29-06, 07:41 PM
  #4  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
Okay, If I understand you, you need a relay that activates off of a pulse, and stays closed until another pulse??? Which it then stays open until another plus... right???
Old 06-29-06, 07:43 PM
  #5  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
correct
Old 06-29-06, 07:44 PM
  #6  
Rotary Enthusiast

 
Sideo's Avatar
 
Join Date: May 2006
Location: reno nevada
Posts: 763
Received 13 Likes on 11 Posts
Ive heard of some called latching relays that are similar to that, dont know where to find one though
Old 06-29-06, 07:50 PM
  #7  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
http://zone.ni.com/devzone/conceptd....256F1C006B7124

Here is a link to a dscription of those but I cant really tell if it is what I am looking for.
I think it would be the 2-coil latching relay?
Old 06-29-06, 07:57 PM
  #8  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
I would need to be able to route the power to a specific coil for that to work and I only have the ability to send pulses to three different places and I origionally wanted four but had to settle for three as that is the limitation of the keyless entry system I am using. I wouldnt be able to even use 2 with this
Old 06-29-06, 08:07 PM
  #9  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
Yep, Mechanical latching relays. DEI (Viper alarms) makes one, as well as they are available from Digikey. Mind that the Digikey ones are pretty expensive (around $38 each last time I ordered 12 volt ones). I use the Tyco/Potter Brumfield S89R11DBD1-12 (DIGIKEY p/n PB514-ND) as it uses conventional .250 terminals (same size as regular 12 volt relay terminals) and is a 12 volt relay (actually will trigger with as little as 9 volts at 553 mA) and has a 15 amp contact rating. Single coil, dual make

The other option if you have a switched 12 volt on source (such as a key in the On position) then you can use a pluse to latch a conventional relay on, until the key is turn off. That takes two conventional relays and a 1n4004 Diode.

Last edited by Icemark; 06-29-06 at 08:09 PM.
Old 06-29-06, 10:07 PM
  #10  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
I think I like the idea of an auto off function that way I do not need to repulse to secure the vehicle.

this is a guess but you would wire the pulse to the first relay which would take the switched 12 volt source and close the load side to the diode that somehow holds the second relay open untill the switched 12V source that is running through the load side of that relay is lost and it will then return to an open circuit untill activated again?

I am still a little unclear how this works.
Old 06-29-06, 10:39 PM
  #11  
Former Moderator. RIP Icemark.
 
Icemark's Avatar
 
Join Date: Apr 2001
Location: Rohnert Park CA
Posts: 25,896
Likes: 0
Received 19 Likes on 19 Posts
Originally Posted by tinvestor
I think I like the idea of an auto off function that way I do not need to repulse to secure the vehicle.

this is a guess but you would wire the pulse to the first relay which would take the switched 12 volt source and close the load side to the diode that somehow holds the second relay open untill the switched 12V source that is running through the load side of that relay is lost and it will then return to an open circuit untill activated again?

I am still a little unclear how this works.
I'll draw you a diagram... remind me with a PM if I still have not posted it by this weekend
Old 06-29-06, 10:51 PM
  #12  
Rotary Enthusiast

Thread Starter
 
tinvestor's Avatar
 
Join Date: May 2005
Location: bartlett IL
Posts: 919
Likes: 0
Received 0 Likes on 0 Posts
thanks again Mark I will have to spend some time doing writeups this winter when everything is done and I am finished playing for the year.

wiring is not my strong suit, but I am trying to get a handle on everything.