2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

need help from prefec b spec 2 owners

Thread Tools
 
Search this Thread
 
Old 11-07-08, 08:03 PM
  #1  
Full Member

Thread Starter
iTrader: (4)
 
rx7dky's Avatar
 
Join Date: Jun 2006
Location: Texas
Posts: 154
Likes: 0
Received 0 Likes on 0 Posts
need help from prefec b spec 2 owners

i just bought a used greddy spec b 2. it is intelled correctly for an external wg. i know either the controller is bad or the actuator is bad. i am getting power to the actuator even when my cotroller is off. it overboost even when off, my spring is an 8lb spring. when i unplug my actuator my wg opens perfectly. any ideas . is there suposed to be power at all times to the actuator? is the actuator shorted out? please help. and yes it is installed correctly. i already talked to greddy but they want me to send them the unit for testings.
Old 11-08-08, 09:14 AM
  #2  
rotorhead

iTrader: (3)
 
arghx's Avatar
 
Join Date: Aug 2004
Location: cold
Posts: 16,182
Received 429 Likes on 263 Posts
the spec 2 has a bad reputation, i would send it to them.
Old 11-08-08, 09:37 AM
  #3  
FC guy

iTrader: (8)
 
Rob XX 7's Avatar
 
Join Date: Oct 2002
Location: Long Island, New York
Posts: 8,714
Received 16 Likes on 16 Posts
I have one and I know it was a pain in the *** to set up, are you sure its set up properly?
Old 11-08-08, 07:09 PM
  #4  
Full Member

Thread Starter
iTrader: (4)
 
rx7dky's Avatar
 
Join Date: Jun 2006
Location: Texas
Posts: 154
Likes: 0
Received 0 Likes on 0 Posts
100% positive, com port to top port of wg and pressure side of turbo to bottom port of wg and nc(normaly closed) port of solenoid. what i need to know is at the harness that goes to solenoid is there any power going to it even when off mode? if so what voltage? is either my controller is not controlling voltage out or my solenoid is reacting even to small amount of voltage. any other ideas to test will be welcome
Old 11-08-08, 09:32 PM
  #5  
brap brap brap

iTrader: (7)
 
AlexG13B's Avatar
 
Join Date: Jul 2003
Location: Florida
Posts: 3,149
Received 43 Likes on 32 Posts
i might be installing mine tomorrow i hope i dont have any trouble
Old 11-08-08, 09:48 PM
  #6  
Slowpoke

iTrader: (3)
 
Hypertek's Avatar
 
Join Date: Jun 2006
Location: Socal
Posts: 5,273
Likes: 0
Received 6 Likes on 6 Posts
just gotta figure it out.. i used to have one in my s13.. i had in the car and didnt know how to set it up for like months til i sat down and seriously learned it.. Its a little confusing
Old 11-08-08, 11:16 PM
  #7  
Senior Member

iTrader: (5)
 
pistones's Avatar
 
Join Date: Oct 2005
Location: nyc
Posts: 726
Received 0 Likes on 0 Posts
i had the same trouble with mine. you need to TEE the NC side that goes to lower port of waste gate to manifold pressure. that is what had me stumped for a while. also make sure the solenoid is facing upright! i had it mounted facing sideways and the thing wouldn't work, put it upright and it works. i know that it sounds stupid but i went back and forth tying it both ways a few times to make sure it wasn't anything else.
Old 11-09-08, 12:34 AM
  #8  
Full Member

Thread Starter
iTrader: (4)
 
rx7dky's Avatar
 
Join Date: Jun 2006
Location: Texas
Posts: 154
Likes: 0
Received 0 Likes on 0 Posts
the compression line is t off . and the solenoid is up right. on the normally open valve air goes by and out the com port, whitch will be the correct way to mount for an internal wg by regulating the air going in to the actuator. with the normaly closed no air goes throug untill solenoid starts letting air by to the top part of the wg (external). when system is off air should not be going by to the comp port from the normaly closed. Problem as soon as the solenoid is conected to harness valve opens to comp port from normally closed even when system is on off mode. problem solenoid or controller?
Old 11-09-08, 01:05 PM
  #9  
Senior Member

iTrader: (5)
 
pistones's Avatar
 
Join Date: Oct 2005
Location: nyc
Posts: 726
Received 0 Likes on 0 Posts
the manual does state that the solenoid will make noise, maybe it's normal. have you tried calling greddy?
Old 11-09-08, 06:09 PM
  #10  
Full Member

Thread Starter
iTrader: (4)
 
rx7dky's Avatar
 
Join Date: Jun 2006
Location: Texas
Posts: 154
Likes: 0
Received 0 Likes on 0 Posts
that is what i am trying to avoid . if i could just find a way to test either the solenoid or the controller i will just order the part needed. if i send it to greddy they will probably tell me to buy a new one.
Old 11-09-08, 10:14 PM
  #11  
Senior Member

iTrader: (5)
 
pistones's Avatar
 
Join Date: Oct 2005
Location: nyc
Posts: 726
Received 0 Likes on 0 Posts
well does it function properly? if it works fine then who cares if it makes noise. make sure you have checked through the install. i thought that something was wrong with mine and was about to buy another one when i figured out that i needed to make corrections on my install.
you said that when you connect the harness that the solenoid, opens. do you have it wired to constant power or switched power? did you wire it up correctly?
Old 11-09-08, 11:15 PM
  #12  
Full Member

Thread Starter
iTrader: (4)
 
rx7dky's Avatar
 
Join Date: Jun 2006
Location: Texas
Posts: 154
Likes: 0
Received 0 Likes on 0 Posts
solenoid dont make noise, it is not working. it does not adjust. it does not open my wg spring even when off, olnly when disconected. so once again it is intalled correctly,just either the solenoid or the controller not working. i will be sending it to greddy tomorrow. then i will post what was wrong with it.

Last edited by rx7dky; 11-09-08 at 11:18 PM.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
SakeBomb Garage
Vendor Classifieds
5
08-09-18 05:54 PM
MazdaspeedR1
The Bad & Fugly Businesses
27
05-22-18 05:58 PM
Devon300zx
2nd Generation Specific (1986-1992)
15
09-16-15 06:57 AM



Quick Reply: need help from prefec b spec 2 owners



All times are GMT -5. The time now is 04:32 PM.