need help from prefec b spec 2 owners

i just bought a used greddy spec b 2. it is intelled correctly for an external wg. i know either the controller is bad or the actuator is bad. i am getting power to the actuator even when my cotroller is off. it overboost even when off, my spring is an 8lb spring. when i unplug my actuator my wg opens perfectly. any ideas . is there suposed to be power at all times to the actuator? is the actuator shorted out? please help. and yes it is installed correctly. i already talked to greddy but they want me to send them the unit for testings.
Reply
Old Nov 8, 2008 | 09:14 AM
  #2  
arghx's Avatar
rotorhead
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (3)
 
Joined: Aug 2004
Posts: 16,205
Likes: 461
From: cold
the spec 2 has a bad reputation, i would send it to them.
Reply
Old Nov 8, 2008 | 09:37 AM
  #3  
Rob XX 7's Avatar
FC guy
Tenured Member 20 Years
iTrader: (8)
 
Joined: Oct 2002
Posts: 8,713
Likes: 17
From: Long Island, New York
I have one and I know it was a pain in the *** to set up, are you sure its set up properly?
Reply
Old Nov 8, 2008 | 07:09 PM
  #4  
rx7dky's Avatar
Thread Starter
Full Member
iTrader: (4)
 
Joined: Jun 2006
Posts: 154
Likes: 0
From: Texas
100% positive, com port to top port of wg and pressure side of turbo to bottom port of wg and nc(normaly closed) port of solenoid. what i need to know is at the harness that goes to solenoid is there any power going to it even when off mode? if so what voltage? is either my controller is not controlling voltage out or my solenoid is reacting even to small amount of voltage. any other ideas to test will be welcome
Reply
Old Nov 8, 2008 | 09:32 PM
  #5  
AlexG13B's Avatar
brap brap brap
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (7)
 
Joined: Jul 2003
Posts: 3,150
Likes: 44
From: Florida
i might be installing mine tomorrow i hope i dont have any trouble
Reply
Old Nov 8, 2008 | 09:48 PM
  #6  
Hypertek's Avatar
Slowpoke
Tenured Member 05 Years
iTrader: (3)
 
Joined: Jun 2006
Posts: 5,273
Likes: 6
From: Socal
just gotta figure it out.. i used to have one in my s13.. i had in the car and didnt know how to set it up for like months til i sat down and seriously learned it.. Its a little confusing
Reply
Old Nov 8, 2008 | 11:16 PM
  #7  
pistones's Avatar
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (5)
 
Joined: Oct 2005
Posts: 736
Likes: 6
From: nyc
i had the same trouble with mine. you need to TEE the NC side that goes to lower port of waste gate to manifold pressure. that is what had me stumped for a while. also make sure the solenoid is facing upright! i had it mounted facing sideways and the thing wouldn't work, put it upright and it works. i know that it sounds stupid but i went back and forth tying it both ways a few times to make sure it wasn't anything else.
Reply
Old Nov 9, 2008 | 12:34 AM
  #8  
rx7dky's Avatar
Thread Starter
Full Member
iTrader: (4)
 
Joined: Jun 2006
Posts: 154
Likes: 0
From: Texas
the compression line is t off . and the solenoid is up right. on the normally open valve air goes by and out the com port, whitch will be the correct way to mount for an internal wg by regulating the air going in to the actuator. with the normaly closed no air goes throug untill solenoid starts letting air by to the top part of the wg (external). when system is off air should not be going by to the comp port from the normaly closed. Problem as soon as the solenoid is conected to harness valve opens to comp port from normally closed even when system is on off mode. problem solenoid or controller?
Reply
Old Nov 9, 2008 | 01:05 PM
  #9  
pistones's Avatar
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (5)
 
Joined: Oct 2005
Posts: 736
Likes: 6
From: nyc
the manual does state that the solenoid will make noise, maybe it's normal. have you tried calling greddy?
Reply
Old Nov 9, 2008 | 06:09 PM
  #10  
rx7dky's Avatar
Thread Starter
Full Member
iTrader: (4)
 
Joined: Jun 2006
Posts: 154
Likes: 0
From: Texas
that is what i am trying to avoid . if i could just find a way to test either the solenoid or the controller i will just order the part needed. if i send it to greddy they will probably tell me to buy a new one.
Reply
Old Nov 9, 2008 | 10:14 PM
  #11  
pistones's Avatar
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (5)
 
Joined: Oct 2005
Posts: 736
Likes: 6
From: nyc
well does it function properly? if it works fine then who cares if it makes noise. make sure you have checked through the install. i thought that something was wrong with mine and was about to buy another one when i figured out that i needed to make corrections on my install.
you said that when you connect the harness that the solenoid, opens. do you have it wired to constant power or switched power? did you wire it up correctly?
Reply
Old Nov 9, 2008 | 11:15 PM
  #12  
rx7dky's Avatar
Thread Starter
Full Member
iTrader: (4)
 
Joined: Jun 2006
Posts: 154
Likes: 0
From: Texas
solenoid dont make noise, it is not working. it does not adjust. it does not open my wg spring even when off, olnly when disconected. so once again it is intalled correctly,just either the solenoid or the controller not working. i will be sending it to greddy tomorrow. then i will post what was wrong with it.

Last edited by rx7dky; Nov 9, 2008 at 11:18 PM.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
SakeBomb Garage
Vendor Classifieds
5
Aug 9, 2018 05:54 PM
MazdaspeedR1
The Bad & Fugly Businesses
27
May 22, 2018 05:58 PM
Devon300zx
2nd Generation Specific (1986-1992)
15
Sep 16, 2015 06:57 AM




All times are GMT -5. The time now is 07:57 PM.