sudden problem

my car's an 84 base. problem started yesterday afternoon as i left for work. i noticed the tach wasn't working, and also the fuel guage and amp guage. it being dark when i got home, i also noticed the backup lights was also no longer working. this morning i realized all the idiot lights don't light up either. what ever is effecting these things, i can't seem to find it. i can't say if this also affects the temp guage as i'm using the stock one. no blown fuses. the alt still seems to be charging(used volt meter). i do remember that one of the wires in the 2 wire plug for the alt will cause the idiot lights not to lightup if not connected. search isn't really giving me anything, maybe just not found the right keywords. any ideas?
Old 03-15-08, 11:19 AM
  #2  
~Insane Burnout
 
93RX7-europa's Avatar
 
Join Date: Mar 2008
Location: Off the grid
Posts: 259
Likes: 0
Received 0 Likes on 0 Posts
NC

Check all fuses, also check to see if the engine is grounded to the body. Check for loose wires, and dirty connectors. However, when you loose so many electrical components it is probably a ground issue.
Mike
Old 03-15-08, 03:35 PM
  #3  
Rotary Freak

 
bliffle's Avatar
 
Join Date: Sep 2002
Location: SF BayArea
Posts: 2,815
Likes: 0
Received 0 Likes on 0 Posts
Yup. Get a cheap $4 battery terminal/connector cleaner brush, you know, the kind that has internal and external wire brushes to clean off the corrosion. Works good.
Old 03-15-08, 03:50 PM
  #4  
Super Moderator

iTrader: (3)
 
gsl-se addict's Avatar
 
Join Date: Jan 2003
Location: Lynchburg, VA
Posts: 5,088
Likes: 0
Received 11 Likes on 11 Posts
Check METER-BACK fuse
Old 03-15-08, 06:37 PM
  #5  
Moderator

Thread Starter
iTrader: (2)
 
rxtasy3's Avatar
 
Join Date: Jun 2002
Location: Spartanburg, SC
Posts: 9,320
Likes: 0
Received 258 Likes on 239 Posts
fuses r fine. it's not a ground issue. i moved the part of the harness that would be under the bin on the driver's side and things work again but now the f/p isn't. if this damn rain would stop so i could get something done i'd be ok. seems to just be a poor connection somewhere, just a matter of finding it. thanx for the help.
Old 03-16-08, 12:45 PM
  #6  
Moderator

Thread Starter
iTrader: (2)
 
rxtasy3's Avatar
 
Join Date: Jun 2002
Location: Spartanburg, SC
Posts: 9,320
Likes: 0
Received 258 Likes on 239 Posts
here's what i've been able to figure out so far. the check relay would click when u turn the switch on, now it don't. probing the wires going to it, the f/p is activated.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
rgordon1979
3rd Generation Specific (1993-2002)
40
03-15-22 12:04 PM
Jeff20B
1st Generation Specific (1979-1985)
73
09-16-18 07:16 PM
stickmantijuana
Microtech
6
11-21-15 10:20 AM
loganneet
General Rotary Tech Support
8
10-03-15 07:51 PM
RotaryBobby
1st Generation Specific (1979-1985)
1
09-10-15 01:33 PM



Quick Reply: sudden problem



All times are GMT -5. The time now is 05:20 PM.