1st Generation Specific (1979-1985) 1979-1985 Discussion including performance modifications and technical support sections

question about the battery cables

Thread Tools
 
Search this Thread
 
Old Mar 18, 2004 | 01:03 PM
  #1  
eddierotary's Avatar
Thread Starter
back with rotaries
Tenured Member 20 Years
iTrader: (7)
 
Joined: Nov 2001
Posts: 2,239
Likes: 1
From: Watertown, NY
question about the battery cables

what gauges is the stock battery cables? i have 4 gauge cable right now and seems not enought i was thinking to get a 2 gauge wire but i dont know if is too overkill, another thing too that i ask this is because i have the battery on the back of the passanger side seat. thanks
Reply
Old Mar 18, 2004 | 01:21 PM
  #2  
anthrax's Avatar
Heck Yes!
Tenured Member 05 Years
 
Joined: Apr 2003
Posts: 1,075
Likes: 0
From: Chatham, Ontario, Canada
Go to a place that specializes in Batteries/Alternators/Starters. They should be able to advise you best.
Reply
Old Mar 18, 2004 | 02:27 PM
  #3  
Jeff20B's Avatar
Lapping = Fapping
Tenured Member 15 Years
iTrader: (13)
 
Joined: Aug 2001
Posts: 15,725
Likes: 91
From: Near Seattle
Add lots of grounds.
Reply
Old Mar 18, 2004 | 02:45 PM
  #4  
purple82's Avatar
Absolute Power is Awesome
Tenured Member: 20 Years
 
Joined: Mar 2001
Posts: 1,973
Likes: 5
From: Issaquah, WA
And you can never have too large of a cable.
Reply
Old Mar 18, 2004 | 04:28 PM
  #5  
smnc's Avatar
EliteHardcoreCannuckSquad
Tenured Member 10 Years
 
Joined: May 2001
Posts: 4,126
Likes: 4
From: Acton, Ontario, Canada
I think the stock cables are a 2 gauge for the + and 4 for the ground...?

I upgraded to a 1 gauge for the +, and I'm replaceing the stock ground with a grounding kit (4 ga I think)....
Reply
Old Mar 18, 2004 | 04:42 PM
  #6  
GavinJuice's Avatar
Leave A Message
Tenured Member 05 Years
 
Joined: Sep 2003
Posts: 1,454
Likes: 1
From: MN
stock most likely would be 4 for 4, there's no reason ANY cable should have a smaller ground than it's positive.

Also where are most people purchasing their grounding kits, and at what points are they being grounded to?
Reply
Old Mar 18, 2004 | 11:04 PM
  #7  
smnc's Avatar
EliteHardcoreCannuckSquad
Tenured Member 10 Years
 
Joined: May 2001
Posts: 4,126
Likes: 4
From: Acton, Ontario, Canada
E-Bay...
Battery Neg terminal to the grounding block I intalled on the strut tower. From there to the firewall, Engine block, alternator... That all so far...
Reply
Old Mar 18, 2004 | 11:11 PM
  #8  
smnc's Avatar
EliteHardcoreCannuckSquad
Tenured Member 10 Years
 
Joined: May 2001
Posts: 4,126
Likes: 4
From: Acton, Ontario, Canada
E-Bay...
Battery Neg terminal to the grounding block I intalled on the strut tower. From there to the firewall, Engine block, alternator... That all so far...