1st Generation Specific (1979-1985) 1979-1985 Discussion including performance modifications and technical support sections

problems with MSD

Thread Tools
 
Search this Thread
 
Old Apr 17, 2004 | 09:09 PM
  #1  
eddierotary's Avatar
Thread Starter
back with rotaries
Tenured Member 20 Years
iTrader: (7)
 
Joined: Nov 2001
Posts: 2,239
Likes: 1
From: Watertown, NY
problems with MSD

io was installing a friend of mines car a MSD 6AL with the rev limiter and it works fine but the rev limiter doesnt work. we put a 7k rpm pill so it doesnt past over that and it did. my question is what i did wrong? thanks
Reply
Old Apr 17, 2004 | 09:24 PM
  #2  
dvcn's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 251
Likes: 0
From: Texas
Did you cut the two wires that set the unit for 4 (2 rotor), 6 or 8 cylinder? They are under a plastic cap held on by a screw.

I just installed two 6AL's and the rev limiters work great.
Reply
Old Apr 17, 2004 | 09:28 PM
  #3  
rototiller1's Avatar
Inspector, Falcon Jet
Tenured Member 05 Years
 
Joined: Mar 2003
Posts: 430
Likes: 0
From: Little Rock
are the dip switches set for a six cyl? just as well it doesnt work, he would not like the ign. dropping out anyway at 7K
Reply
Old Apr 17, 2004 | 09:37 PM
  #4  
eddierotary's Avatar
Thread Starter
back with rotaries
Tenured Member 20 Years
iTrader: (7)
 
Joined: Nov 2001
Posts: 2,239
Likes: 1
From: Watertown, NY
i think my friend did cut the cables inside the cap. because he told me something of that.

rototiller1: what the dip swices your talking about?

ohh and BTW. i forgot to mension that it is for a 4 cilinder car, i didnt wanna mension this because i dont want this tread on another place so please dont move it. thanks
Reply
Old Apr 17, 2004 | 09:56 PM
  #5  
dvcn's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 251
Likes: 0
From: Texas
There aren't dip switches.

-Veryify that the two wires are cut and not accidentally touching.

-try a different pill, a very low rpm one, I think a 3k pill is also supplied with the 6AL. Try the 6k pill too.

-ohm out the 7k pill, it should be approximately 3.14k ohms.

It is possible, but very rare, that you have a bad box.
Reply
Old Apr 17, 2004 | 11:35 PM
  #6  
rototiller1's Avatar
Inspector, Falcon Jet
Tenured Member 05 Years
 
Joined: Mar 2003
Posts: 430
Likes: 0
From: Little Rock
I'm sorry my mallory 6al has dip switches
Reply
Old Apr 18, 2004 | 02:54 PM
  #7  
mwatson184's Avatar
holley guy
Tenured Member 10 Years
 
Joined: Feb 2003
Posts: 898
Likes: 1
From: K.C. MO
You would have to install two separate msd's, one to limit the leading, one for the trailing. It is probably cutting the spark to the leading and the trailing is keeping it going.

-Marques
Reply
Old Apr 18, 2004 | 02:57 PM
  #8  
eddierotary's Avatar
Thread Starter
back with rotaries
Tenured Member 20 Years
iTrader: (7)
 
Joined: Nov 2001
Posts: 2,239
Likes: 1
From: Watertown, NY
we tryied the 3K one too and it still doenst work. i didnt have much time to check if he did cut the wires so im check the tomorow. thanks
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Medevack1
Naturally Aspirated Performance Forum
13
Nov 10, 2017 04:53 PM
The1Sun
1st Generation Specific (1979-1985)
7
Sep 18, 2015 07:13 PM
gxl90rx7
Haltech Forum
4
Sep 14, 2015 03:09 PM




All times are GMT -5. The time now is 04:52 PM.