Pulsation Dampener issues with higher Fuel Pressure / Single !?
#1
No it's not Turbo'd
Thread Starter
Pulsation Dampener issues with higher Fuel Pressure / Single !?
I ask, cause I am going to up the pressure, and have a new regulator, so the question is, with the increase and modification required to go single, is the stock FPD a good way to go !? Or does it need to get upgraded as well !?
I know there's a whole lot of argueing about if you need it or not, but I have all kinds of stuff on my FD that is possible that I don't need like the AST, and I'm not going to start removing things just because I can't see the wisom in it, I'm no fuel expert, so I leave that to them, I don't expect any of you to tell me about my field of expertise.
So, is there a better FPD !? Like a GM one ? Like the map sensor, that can handle more pressure, or is the factory one fine, up to say 100 PSi !?
BTW, I believe factory pressure @ idle is 38 psi !? and goes up a bit once WOT !? I have Stock Lines, Cosmo Pump, and plan on running 550 Pri. and 1680 Sec. if that helps...
I know there's a whole lot of argueing about if you need it or not, but I have all kinds of stuff on my FD that is possible that I don't need like the AST, and I'm not going to start removing things just because I can't see the wisom in it, I'm no fuel expert, so I leave that to them, I don't expect any of you to tell me about my field of expertise.
So, is there a better FPD !? Like a GM one ? Like the map sensor, that can handle more pressure, or is the factory one fine, up to say 100 PSi !?
BTW, I believe factory pressure @ idle is 38 psi !? and goes up a bit once WOT !? I have Stock Lines, Cosmo Pump, and plan on running 550 Pri. and 1680 Sec. if that helps...
#3
Rotary Poseur
Join Date: Feb 2001
Location: Richmond, BC, Canada
Posts: 718
Likes: 0
Received 0 Likes
on
0 Posts
I went with this one: http://www.injector.com/fueldampers.php
#7
No it's not Turbo'd
Thread Starter
Originally Posted by HedgeHog
I went with this one: http://www.injector.com/fueldampers.php
But what I meant was, was it easy to install, and have you noticed any difference, did you ever run without !? Have you seen consistant pressure, over someone else's setup ?
-DC
Trending Topics
#8
boost > *
Join Date: Aug 2004
Location: buffalo, ny
Posts: 1,527
Likes: 0
Received 0 Likes
on
0 Posts
so if the fpd is on the primary rail, which i'm keeping stock with the 550's...... do i need to get an aftermarket one? i have the rx7store secondary rail / 1600's and an sx fpr
#9
Mad Man
Originally Posted by HedgeHog
I went with this one: http://www.injector.com/fueldampers.php
Right now my set-up(in process) is a fuell cell with a Bosch in tank feeding a 1 litre surge tank w/-8 line, feed/return. From the surge, it is SX -10 filter/Aeromotive A1000/-10 to the front"Y" into two -6 to modified stock rails/-8(2) to the FPR and -8 return. injectors are 720/1680. I was told by both SX, and Aeromotive that the FPR has an FPD feature, and an additional FPD was redundant. Thoughts? Also, it seems most people w/surge tanks return to the Surge. to me this exacerbates the fuel heating problem. I am planing on returning to the cell instead. the only downside seems like you might not get the last teaspoon of fuel, other than that I see no problem. Comments? Carl
#10
Rotary Enthusiast
iTrader: (5)
Carl,
Good point about the fuel heating. I think the point of running the return to the surge tank is to help insure the surge tank stays full under all conditions. If your in-tank pump can keep up with the in-line pump and doesn't ever get starved, return to the fuel cell would be ok. Most people use a smaller capacity in-tank pump to supply the surge tank.
Jack
Good point about the fuel heating. I think the point of running the return to the surge tank is to help insure the surge tank stays full under all conditions. If your in-tank pump can keep up with the in-line pump and doesn't ever get starved, return to the fuel cell would be ok. Most people use a smaller capacity in-tank pump to supply the surge tank.
Jack
#11
boost > *
Join Date: Aug 2004
Location: buffalo, ny
Posts: 1,527
Likes: 0
Received 0 Likes
on
0 Posts
Originally Posted by Carl Byck
I was told by both SX, and Aeromotive that the FPR has an FPD feature, and an additional FPD was redundant.
#12
boxed in and drawn out
Join Date: Dec 2003
Location: Bayouself
Posts: 555
Likes: 0
Received 0 Likes
on
0 Posts
Originally Posted by adictd2b00st
so i should be ok with my setup then? as of now i just left the stock fpd how it was
Unless Carl can advise otherwise............?
#13
Mad Man
1. The surge tank is primarily for starvation prevention while cornering. It has the added advantage of helping to scavenge evey last drop of fuel. Drag racers often build a small well, or surge tank into the rear of their stock tank to prevent fuel starvation following launch. With a 1/3 of a tank or more you won't have a problem.
2. Since the pump supplying the surge tank is not operating against any pressure even a huge main pump will never outflow the small pump which is trying to push 60-80psi.
Still would like to hear from Hedgehog...
2. Since the pump supplying the surge tank is not operating against any pressure even a huge main pump will never outflow the small pump which is trying to push 60-80psi.
Still would like to hear from Hedgehog...