MoTeC Area is for discussing the MoTeC EMS.

MoTeC m2r wiring cooling fan help

Thread Tools
 
Search this Thread
 
Old Jan 18, 2014 | 05:41 AM
  #1  
imitek's Avatar
Thread Starter
imitek
Tenured Member: 15 Years
 
Joined: Jul 2007
Posts: 380
Likes: 5
From: portsmouth
m2r wiring cooling fan help

iv finaly got aroud to wiring up ecu got engine running again
but its running piggyback with stock and something is up with stock ecu causing cooli g fans to stay on when ignition is turned on
but any way my plan is to remove the standard ecu and just run m2r

so my question is i have planed on using the 4amp aux 1 for boost controler
the other aux output is only 0.6amp is that sufficiant for triggering a relay to turn on engine fan
from what i can remember current draw is aprox 250mAH is this correct

have i missed somthing
Reply
Old Mar 1, 2014 | 02:32 PM
  #2  
dguy's Avatar
Rotary Freak
Tenured Member: 20 Years
Liked
iTrader: (8)
 
Joined: Apr 2006
Posts: 1,657
Likes: 332
From: sb
You've got 600mA to work with. So yes, you can trigger a standard bosch 20 (or their high output model) with Aux4 without a problem.

-David Guy
Reply
Old Apr 9, 2014 | 02:43 PM
  #3  
imitek's Avatar
Thread Starter
imitek
Tenured Member: 15 Years
 
Joined: Jul 2007
Posts: 380
Likes: 5
From: portsmouth
Originally Posted by dguy
You've got 600mA to work with. So yes, you can trigger a standard bosch 20 (or their high output model) with Aux4 without a problem.

-David Guy
diddnt think any 1 replied i never got a email
but manyy thanks for your help
Reply
Old Apr 22, 2014 | 07:19 PM
  #4  
elwood's Avatar
Rotary Freak
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Mar 2003
Posts: 1,588
Likes: 46
From: Michigan
I used my other aux output to run 4 coils and reverted to a basic temp switch w/relay to operate the fan. It's on at 195 deg / off at 185 deg, and I run a 180 deg thermostat. It works great. My system works well enough that the fan only runs when I'm parked and idling.

BTW - glad to see some posts on this section. We M2R people need to stick together.
Reply
Old Dec 5, 2014 | 12:18 PM
  #5  
imitek's Avatar
Thread Starter
imitek
Tenured Member: 15 Years
 
Joined: Jul 2007
Posts: 380
Likes: 5
From: portsmouth
Yea for some reason my notification is disabled any way i will be doin wright up once i have all my settings sorted ive been getting cofuesd
Over my resent problm ive made another thread for that
But as for my temp control its all sorted the m2r is bit weird on temp control i would say to set the temps down to what ever the temp of sensor is and off temp to see if u getting triggering once warmed up because the m2r
Can not trigger on the cooling fan (myn cant anyway) in the diagnostics section
Reply
Old Dec 5, 2014 | 12:18 PM
  #6  
imitek's Avatar
Thread Starter
imitek
Tenured Member: 15 Years
 
Joined: Jul 2007
Posts: 380
Likes: 5
From: portsmouth
Yea for some reason my notification is disabled any way i will be doin wright up once i have all my settings sorted ive been getting cofuesd
Over my resent problm ive made another thread for that
But as for my temp control its all sorted the m2r is bit weird on temp control i would say to set the temps down to what ever the temp of sensor is to see if the fan is getting triggerd and off temp to 0deg to see if u getting triggering the m2r once u getting trigger set ur normal temps
Canot trigger on the cooling fan (myn cant anyway) in the diagnostics section myn is now fine an dandy
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
gxl90rx7
Haltech Forum
4
Sep 14, 2015 03:09 PM
ray green
1st Gen General Discussion
2
Sep 2, 2015 06:35 AM




All times are GMT -5. The time now is 10:29 AM.