ok it all started when i plugged in the lap top to ajust analog out 2 to work with my rtek's 0-5 volt in.

so basicly i hooked up a lap top that was low on battery, went to edit the volt sweep...

0=7.35
5=22.39


i did that and clicked program.....

didnt work? ok so now i got my analog guage on my dash that isnt reading correctly and my rtek isnt displaying correctly both are reading all the way lean. 5 volts

so i go back in and notice that the factory default settings were in use. so i programed both analog 1 and 2 and it saved but didnt show different on my guages.....

i did it again seeing that the factory default was in use again


by this time i plugged in the lap top thinking it was a data transfer rate issue.

i did it one last time then my guages started going CRAZY . back and forth all over the place. so i looked at the on screen digital display. it was all over the place
i call inovate and they tell me to calibrate the o2 sensor and upgrade firmware


2 hours later after dealing with a heat warped bung for the 02 sensor. i got it out. calibrated. put back in and upgraded firmware

problem was still the same so i got back on the phone with inovate and it MAGICLY started working again.... i programed the analog outs and all was well for abotu 2 weeks


the analog outs messed up again. i think its because of my screw off battery disconect behind passanger seet. sometimes i forget to turn of ACC and sometimes the battery arks several times and causes possible calibration or reset of the lc-1 system

THAT PROBLEM ASSIDE


i had another problem last night


i went to set the analog outs again. because they were not workingg on my rtek or analog gauge. i hooked up the computer and used lm programer and recalibrated sensor on screen. i then went into analog 1 and 2 and noticed they were both set in lamba. i clicked over to afr and went to change to above said spec for 0-5 volt sweep. it said it was unable to do so because my values were incorrect. idk wtf is wrong with it at this point so i just turn on the car and go to pull up the on screen digital display. it said "could not connect" said it was less then a 9v on the battery and or it was not connected. though it was and i had just recalibrated it via usb port com port 10. which has always worked in the past. lap top does not have serial port.



soooooooooooooooo i glance down at my rtek and notice my af ratio is accurate.... though i acomplished NOTHGING but a recalibration. the rtek was reading correct a/f ratio for idle so i went driving and again it was responding correctly and readingg correct a/f ratio




i am still unable to reprogram analog outs. and i am still unable to pull up the lc-1 on digital onscreen display on lap top...

my analog 2 is not working on my analog gauge pod.
Old 08-05-09, 10:13 PM
  #2  
Where does this bolt go?

iTrader: (8)
 
FixableUnknown's Avatar
 
Join Date: Oct 2008
Location: TN
Posts: 315
Likes: 0
Received 0 Likes on 0 Posts
It sounds like you may have a ground issue on the reset problem. I had the same problem with the scale input. It would say values must be between a certain range. I put whatever values into it to stop getting the error message and then it would let me go to the first tab. Go to the first tab (info/set afr) and make sure its on 14.7 gasoline, mine went to a custom tab somehow and wouldn't let me set the afr scale. When you set the scale, only change one thing at a time. Once you make a scale change, load it and wait a few minutes and then shut down the program. I have read on other forums if you make a change and unplug the data cable with the power still on, it will go back to a default setting. I also found that my DB analog gauge works best when set to 0.000v = 7.35 5.000 = 22.39. Here is a link to innovates forum http://images.google.com/imgres?imgu...a%3DN%26um%3D1 I found some good info there about connection issues.
Hope this helps. Let me know how it turns out.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Skeeg
3rd Generation Specific (1993-2002)
3
09-12-15 10:11 AM
t-von
3rd Generation Specific (1993-2002)
9
09-10-15 01:56 PM
Steven_McKinley
General Rotary Tech Support
12
09-05-15 10:48 AM



Quick Reply: innovate LC-1 issues, hardware failure?



All times are GMT -5. The time now is 05:16 PM.