93 FD: Need some help identifying connector
#1
93 FD: Need some help identifying connector
Where does that connector plug in to? I have the AC harness and there is a connector that's plugged in to an empty counterpart and taped up. It seems like it would fit in there but the wires are of a different color. I checked the AC diagram and I can't seem to find those wires. Any help appreciated.
#2
Ok I think I figured it out, just needed some sleep. So I already knew this was the evaporator thermo switch, for some reason these wires don't show up in the electrical diagram. There are 2 versions of the thermo switch depending on which expansion valve you have in your evaporator (nippon denso or MANA)
These wires together with the plug go in to the G-08 connector on page Z-68 in the FSM. The Evap thermo switch is normally closed, and 1 wire is jumped so this completes the G-08 circuit until the evap reaches a certain temp (40 deg I beleive) then it opens the circuit to turn off the AC compressor. The blank connector allows you to wire up the G-08 to bypass the thermo switch. Whew....
Feel free to correct me if I'm wrong.
These wires together with the plug go in to the G-08 connector on page Z-68 in the FSM. The Evap thermo switch is normally closed, and 1 wire is jumped so this completes the G-08 circuit until the evap reaches a certain temp (40 deg I beleive) then it opens the circuit to turn off the AC compressor. The blank connector allows you to wire up the G-08 to bypass the thermo switch. Whew....
Feel free to correct me if I'm wrong.