I have a 13B-REW but am running the Cosmo upper & lower intake manifold. I just went to your website but could not pull up any product lists.
I was wondering if you have a secondary rail for the Cosmo manifold? If you do not, will your primary rail clear/fit for use with the kg parts secondary rail (I am currently running a kg parts primary w/ID 2000's, & a kg parts Cosmo secondary w/ Bosch 1680's).
At a minimum I would really like to use your primary rail w/ my ID2000's as I am sick and tired of the junk kg parts primary and all the leaking issues.
I appreciate your time and help,
Alex aka AFAwaterpolo
I was wondering if you have a secondary rail for the Cosmo manifold? If you do not, will your primary rail clear/fit for use with the kg parts secondary rail (I am currently running a kg parts primary w/ID 2000's, & a kg parts Cosmo secondary w/ Bosch 1680's).
At a minimum I would really like to use your primary rail w/ my ID2000's as I am sick and tired of the junk kg parts primary and all the leaking issues.
I appreciate your time and help,
Alex aka AFAwaterpolo
#4
Registered User
iTrader: (13)
Sorry for the delayed response, We weren't aware we had a subforum!
Anyways if you haven't been able to find it yet here's the address
Thanks!
13B-RE Rail Set | Full Function Engineering
Anyways if you haven't been able to find it yet here's the address
Thanks!
13B-RE Rail Set | Full Function Engineering
#5
Junior Member
iTrader: (1)
Join Date: Jun 2013
Location: Japan
Posts: 14
Likes: 0
Received 0 Likes
on
0 Posts
I have a cosmo 13b and i am looking at ordering fuel rails and injectors. what is the difference in using the 48 or 60mm injectors?
I have a haltech ps2000 and will be running pump gas with t51 around 1 bar are the id 2000 injectos controllable enough to run them in primary?
I have a haltech ps2000 and will be running pump gas with t51 around 1 bar are the id 2000 injectos controllable enough to run them in primary?
#6
Registered User
iTrader: (13)
RZ20B,
The size is so that we can ensure correct fitment for your application.
We have customers running ID2000's as primaries on large street ports on E85 with great results (at 3 bar base pressure). For small ports and gasoline the ID1000 or ID1300 is a better choice if possible.
Thanks!
The size is so that we can ensure correct fitment for your application.
We have customers running ID2000's as primaries on large street ports on E85 with great results (at 3 bar base pressure). For small ports and gasoline the ID1000 or ID1300 is a better choice if possible.
Thanks!