AEM EMS Area is for discussing the AEM Engine Management System!

AEM Does anyone have this? AEM wideband

Thread Tools
 
Search this Thread
 
Old Sep 18, 2004 | 08:54 AM
  #1  
MichaelFregoe's Avatar
Thread Starter
Senior Member
Tenured Member 10 Years
iTrader: (1)
 
Joined: Mar 2004
Posts: 446
Likes: 0
From: VERY upstate NY
Smile Does anyone have this? AEM wideband

http://www.rx7store.net/index.asp?Pa...ROD&ProdID=814

I like it because it can fit where I currently have the narrowband A/F guage and does not take much room elsewhere.
Reply
Old Sep 22, 2004 | 06:30 PM
  #2  
silverrotor's Avatar
Moderator
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Mar 2002
Posts: 7,592
Likes: 5
From: Toronto, Corporate Canada
I have It. As of now I have It boxed up and will be replaced with my narrow band A/F Ratio Guage. I like how It Is offered with an adjustable calabration output.
Reply
Old Sep 24, 2004 | 12:02 AM
  #3  
BLitzed33's Avatar
...
Tenured Member 10 Years
 
Joined: Aug 2004
Posts: 802
Likes: 0
From: md
they are cool, but suposedly only read to 11.0 A/F and below that, go OL "offline"
Reply
Old Sep 25, 2004 | 11:13 AM
  #4  
silverrotor's Avatar
Moderator
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Mar 2002
Posts: 7,592
Likes: 5
From: Toronto, Corporate Canada
I understand It reads below 11.0 A/F *when datalogging* - but does not not display this on the actual Guage.
Reply
Old Sep 28, 2004 | 11:49 AM
  #5  
z8cw's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Jan 2004
Posts: 341
Likes: 0
From: Colorado
That is correct. The gauge is limited to 11 to 17 I believe but the sensor reads a wide range which can be displayed or logged with your EMS or PC.
Reply
Old Sep 28, 2004 | 01:34 PM
  #6  
TailHappy's Avatar
Addicted to Track
Tenured Member 15 Years
 
Joined: Jan 2002
Posts: 903
Likes: 0
From: NC
I have the older non-gauge type and it's been totally useless up to this point. Apparently it does not interface well with the datalogit, causing lots of noise and poviding a useless signal. I'm not the only one to experience this. I think if you use it with the AEM EMS you'll probably be ok, but if you're buying it for a PFC/datalogit, you may want to look elsewhere. Here's a thread I started on the AEM forum that basically went nowhere other than confirming that others have the same problem.......
http://forum.aempower.com/bbs/viewto...?p=55651#55651
There's also several others on the datalogit forum with my same woes...

Between the problems with the AEM CDI and the AEM UEGO, I think I'm fniished with AEM....
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Logan Reinisch
General Rotary Tech Support
44
Sep 17, 2018 12:20 PM
mulcryant
General Rotary Tech Support
5
Oct 4, 2015 12:18 AM




All times are GMT -5. The time now is 11:37 PM.