question about wastegate control
#1
Lawn Ornament
Thread Starter
question about wastegate control
ok, i f take the pill out for the wastegate i get a perfect 7 psi, if i put the stock pill in i get 10 psi, when i put my boost controller (dawes) on, i get 10psi and cannot change that, wether i tighten or loosen it, i also hear a leak after 4300 RPM, and am getting 7 psi on my secondary, it is not the CRV becuase i have capped it and have gotten the same exact boost pattern, and still hear the noise.
#2
Eye In The Sky
iTrader: (2)
Join Date: Feb 2001
Location: In A Disfunctional World
Posts: 7,894
Likes: 0
Received 114 Likes
on
66 Posts
With your DAWES controller, it should be connected between the #1 turbo outlet and the WG actuator. There should not be any bleed off pills/devices in that circuit.
The outlet hose from the WG actuator should not connect to the piping that goes up to WG solenoid unless you want to try a combination controller. Instead, on this outlet nipple; you should
install a small bleeder pill.
I have a similar device that was made for 4 bangers. The pill sizes it came with were way too large. Install the stock WG pill there.
Or even a smaller pill.
The outlet hose from the WG actuator should not connect to the piping that goes up to WG solenoid unless you want to try a combination controller. Instead, on this outlet nipple; you should
install a small bleeder pill.
I have a similar device that was made for 4 bangers. The pill sizes it came with were way too large. Install the stock WG pill there.
Or even a smaller pill.
Thread
Thread Starter
Forum
Replies
Last Post
Skeese
Adaptronic Engine Mgmt - AUS
65
03-28-17 03:30 PM