3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

M2 stage 3 with 99 twins

Thread Tools
 
Search this Thread
 
Old 08-31-03, 06:57 AM
  #1  
mcf
Full Member

Thread Starter
 
mcf's Avatar
 
Join Date: Nov 2001
Location: Toronto
Posts: 228
Likes: 0
Received 0 Likes on 0 Posts
M2 stage 3 with 99 twins

I am contemplating the winter project. I've got a set of 99+ twins and (before I put them on) I am looking for advice. 1) Does anyone here run 99 twins with an M2 stage 3 and do they perform different enough from stock twins to require additional tuning? 2) If I go with the Power fc, would I need to upgrade my injectors? Any other advice/ comments are welcome. FWIW, I will stay non-seq so please no advice to the contrary.

Thanks.
Old 08-31-03, 07:07 AM
  #2  
FD title holder since 94

iTrader: (1)
 
Tim Benton's Avatar
 
Join Date: Mar 2001
Location: Cedartown, Ga
Posts: 4,170
Received 28 Likes on 21 Posts
You should be fine with the M2 ecu. Having talked to Brian many times in the past about it, his maps are on the generously rich side. Just maintain the boost level you are on with the stock twins (12?) and your safe.

Tim
Old 08-31-03, 07:21 AM
  #3  
Recovering Milkaholic

iTrader: (7)
 
Fd3BOOST's Avatar
 
Join Date: Jan 2002
Location: Budds Creek, Maryland
Posts: 8,203
Likes: 0
Received 0 Likes on 0 Posts
On a m2 stage III I ran up to 14 psi on 99 twins without incident for almost a year.
Thats just a testimonial not an indorsment
Old 08-31-03, 09:33 AM
  #4  
Senior Member

 
ludeowner's Avatar
 
Join Date: Dec 2001
Location: Somewhere in California
Posts: 468
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by Fd3BOOST
On a m2 stage III I ran up to 14 psi on 99 twins without incident for almost a year.
Thats just a testimonial not an indorsment
Dude that's nuts!!!

Did you run that on 93 octane? also if you dont mind me asking what were your mods at the time? and also what RWHP did you see with that setup?

I have an M2 stg III ECU as well, and I am contemplating adding in a MP after I add a FMIC (or SMIC). I think that if I can control the boost, I should be fine.
Old 08-31-03, 10:53 AM
  #5  
Recovering Milkaholic

iTrader: (7)
 
Fd3BOOST's Avatar
 
Join Date: Jan 2002
Location: Budds Creek, Maryland
Posts: 8,203
Likes: 0
Received 0 Likes on 0 Posts
You can't run a midpipe with a M2 ecu and not expect to blow up.
At the time I was running with a CB/DP/Intake/PFSIC/99 twins/M2 Stage III.
Old 08-31-03, 12:27 PM
  #6  
mor
Full Member

 
mor's Avatar
 
Join Date: May 2002
Location: Irvine, CA
Posts: 185
Likes: 0
Received 0 Likes on 0 Posts
I've talked to M2 and the reason why they say you can't run a midpipe is because boost creep.

However, I mentioned to them that I ported the wastegate so they said as long as I control the boost then it's fine.

The key here is maintaining safe boost levels.
Old 08-31-03, 01:38 PM
  #7  
Recovering Milkaholic

iTrader: (7)
 
Fd3BOOST's Avatar
 
Join Date: Jan 2002
Location: Budds Creek, Maryland
Posts: 8,203
Likes: 0
Received 0 Likes on 0 Posts
There ya go.
Old 08-31-03, 02:14 PM
  #8  
Mr. Links

iTrader: (1)
 
Mahjik's Avatar
 
Join Date: Aug 2001
Location: Kansas City, MO
Posts: 27,595
Received 40 Likes on 26 Posts
Originally posted by mor
I've talked to M2 and the reason why they say you can't run a midpipe is because boost creep.

However, I mentioned to them that I ported the wastegate so they said as long as I control the boost then it's fine.

The key here is maintaining safe boost levels.
That's pretty much true of any ECU, including programable ones.

If you have uncontrollable boost creep beyond what your car is tuned for, then you risk detonation no matter what ECU you are running.
Old 08-31-03, 03:29 PM
  #9  
Do it right, do it once

iTrader: (30)
 
turbojeff's Avatar
 
Join Date: Apr 2001
Location: Eugene, OR, usa
Posts: 4,830
Likes: 0
Received 12 Likes on 8 Posts
I agree. Keep the boost under control and you can run a MP. Basically the stock ECU is good for stage III mods if you keep the boost at 10psi.

Mark,

The difference between the 99+ turbos and the stockers should be that the 99+ turbos don't heat the air as much for the same boost level. That should mean that no additional tuning is required, but you will get a little more performance out of the car since the IC won't have to cool the intake charge down as much.
Old 08-31-03, 08:28 PM
  #10  
Senior Member

 
ludeowner's Avatar
 
Join Date: Dec 2001
Location: Somewhere in California
Posts: 468
Likes: 0
Received 0 Likes on 0 Posts
So who wants to be the guinea pig to test out a MP with their M2 ECU?
Old 09-01-03, 10:26 AM
  #11  
Rotary Freak

 
cruiser's Avatar
 
Join Date: Dec 2002
Location: Slovenia, Europe
Posts: 2,522
Likes: 0
Received 0 Likes on 0 Posts
I am next week when I install DP, intakes and M2 Stage3 ECU I bought off jpandes.

Currently there are no problems at keeping the boost at 10psi with ProfecB.
Old 09-01-03, 01:23 PM
  #12  
Rotary Freak

 
jpandes's Avatar
 
Join Date: Mar 2001
Location: San Francisco, CA
Posts: 2,236
Likes: 0
Received 1 Like on 1 Post
I ran 13-14 psi for over a year with an Intake, DP,CB, SMIC, HF CAT, Ign Amp with no issues.
Old 09-01-03, 08:57 PM
  #13  
Rotary Enthusiast

 
cover8's Avatar
 
Join Date: Apr 2002
Location: SC
Posts: 917
Likes: 0
Received 1 Like on 1 Post
MCF,

Thanks for all of your help...my advice to you is sorta expensive, but I have learned the hardest way....please buy a wideband, even a used one from the forum if you can. I blew four motors before i bought one and finally realized that I had a voltage problem to my pump...not consistently getting 12 volts. Finally got a wideband to tell me that I was not getting enough fuel...did four perfect installations....even had a brand new supra fuel pump and had great idle pressure...but when i taped the guage to my windsheild, lost pressure after 4.5k...and was going lean. I could not figure out why my voltage was so erratic.

finally, scraped some paint and ground well...got 10ga wire and a 5pin relay from rice store and wire the supra pump to 12 volts all the time....now I run the 99 spec twins to 17psi and still maitain 95% duty on stock injectors at 11.2 a/f.

hope all goes well...my used wideband cost me $400...spent close to 4k on rebuying motors.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Turblown
Vendor Classifieds
12
10-17-20 03:25 PM



Quick Reply: M2 stage 3 with 99 twins



All times are GMT -5. The time now is 05:47 AM.