3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

M2 Radiator!

Old Jul 19, 2002 | 11:05 AM
  #1  
Jason's Avatar
Thread Starter
The one
iTrader: (5)
 
Joined: Jul 2001
Posts: 3,862
Likes: 5
From: Fort Worth, TX
M2 Radiator!

I got some of these in and posted a couple of pics at http://66.216.67.51/product.asp?0=209&1=251&3=651

Its a direct drop in with no modifications. Very nice welds. Im going to install it on my car this weekend.

Jason
www.rx7store.net
Reply
Old Jul 19, 2002 | 11:14 AM
  #2  
Full Member
Tenured Member 05 Years
 
Joined: Apr 2002
Posts: 82
Likes: 0
From: Northern CA
Jason, I have been waiting for these from M2! Do you still have them in stock? If so, I will order one today! Thanks.
Reply
Old Jul 19, 2002 | 11:21 AM
  #3  
Jason's Avatar
Thread Starter
The one
iTrader: (5)
 
Joined: Jul 2001
Posts: 3,862
Likes: 5
From: Fort Worth, TX
Yea, I got in 7 of them today.

Jason
Reply
Old Jul 19, 2002 | 12:03 PM
  #4  
Street King's Avatar
*** Bless Texas!
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 775
Likes: 0
From: TX
Do you happen to know the deminsions of the M2, Fluidyne, and Koyo and rows eahc has.

Jonas
Reply
Old Jul 19, 2002 | 12:07 PM
  #5  
neo_omega's Avatar
***Moderator***
Tenured Member 15 Years
 
Joined: Feb 2001
Posts: 2,413
Likes: 0
From: Chicago
what's the different between M2, Fluidyne and Koyo?

Jason, could you do a comparsion for us?
Reply
Old Jul 19, 2002 | 12:10 PM
  #6  
vudoodoodoo's Avatar
Rotary Freak
Tenured Member 10 Years
 
Joined: Aug 2001
Posts: 1,635
Likes: 0
From: Boston, MA
Wow, it looks really nice.
I gotta get a radiator soon. Was gonna go w/ Fluidyine, but no I want the M2.
Reply
Old Jul 19, 2002 | 12:19 PM
  #7  
Jason's Avatar
Thread Starter
The one
iTrader: (5)
 
Joined: Jul 2001
Posts: 3,862
Likes: 5
From: Fort Worth, TX
The Koyo is the thickest. It does have some fitment issues. I think its 3 inches thick.

The M2 is 2 inches thick. It has nicer welds than both the fluidyne and Koyo and is a direct drop in.

I think the Fluidyne is 2 inches thick also.

Jason
Reply
Old Jul 19, 2002 | 12:24 PM
  #8  
neo_omega's Avatar
***Moderator***
Tenured Member 15 Years
 
Joined: Feb 2001
Posts: 2,413
Likes: 0
From: Chicago
If I go with FMIC, Koyo fitment will not be a issue, will it?
Reply
Old Jul 19, 2002 | 12:38 PM
  #9  
SPOautos's Avatar
Hey, where did my $$$ go?
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 4,413
Likes: 0
From: Bimingham, AL
How thick is stock??? I thought it was 2", are these actually larger than stock???

STEPHEN
Reply
Old Jul 19, 2002 | 01:22 PM
  #10  
Full Member
Tenured Member 05 Years
 
Joined: Apr 2002
Posts: 82
Likes: 0
From: Northern CA
From what I understand the total coolant capacity is much greater than the stock radiator, plus more surface area for the coolant. I have seen the M2 installed and it is a great fit and looks good. It also mates well with the M2 medium SMIC. Also the fans set well on the M2 radiator. All reasons why I just bought one.
Reply
Old Jul 19, 2002 | 05:27 PM
  #11  
futurerexowner's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 318
Likes: 0
From: Santa Barbara, California
How would fitment be if you were to use this in the stock location and an M2 medium SMIC?
Reply
Old Jul 19, 2002 | 05:52 PM
  #12  
Full Member
Tenured Member 05 Years
 
Joined: Apr 2002
Posts: 82
Likes: 0
From: Northern CA
Fitment is drop-in with the M2 medium SMIC.
Reply
Old Jul 19, 2002 | 06:00 PM
  #13  
GoRacer's Avatar
Speed Mach Go Go Go
Tenured Member 15 Years
iTrader: (2)
 
Joined: Oct 2001
Posts: 4,772
Likes: 2
From: My 350Z Roadster kicks my RX7's butt
Will it work for Auto's

My friend had to special order an AWR because it was the only one that had connections for the transmission cooler. Does the M2 offer those connections?
Reply
Old Jul 19, 2002 | 08:41 PM
  #14  
Nathan Kwok's Avatar
Rotary Enthusiast
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 1,025
Likes: 4
From: Huntington Beach, CA, USA
If it didn't fit with the M2 IC that would be pretty sad wouldn't it? BTW I think the right numbers are: stock is 25mm (27mm for the series 8) (1"), Fluidyne is 38mm (1.5"), and Koyo is 52mm (2"). If the M2 is 2" (52mm) and drops in thats pretty good. It would be nice to see a comparo between the 3.
Reply
Old Jul 20, 2002 | 12:04 AM
  #15  
PVerdieck's Avatar
Rotary Freak
Tenured Member 10 Years
 
Joined: May 2002
Posts: 1,742
Likes: 0
From: Houston
Crap! Did my Koyo ship yet? If not, I want to switch.
Reply
Old Jul 20, 2002 | 12:26 AM
  #16  
violator's Avatar
Senior Member
Tenured Member 05 Years
 
Joined: Feb 2002
Posts: 265
Likes: 0
From: Vancouver, Canada
what about the PWR one guys? i just purchased one from .
Reply
Old Jul 22, 2002 | 11:52 PM
  #17  
artowar2's Avatar
Senior Member
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 464
Likes: 0
From: Was SoCal
I just measured my still-new-in-box Koyo, and the thickness, as measured from the side, is 2.5 inches. The stock radiator seemed to be close to 1 inch. Jason shipped one of the new M2 radiators to me today, so I'll be able to compare it to the Koyo before picking one to install. I'll put the other one up for sale.
Reply
Old Jul 23, 2002 | 12:22 AM
  #18  
Nathan Kwok's Avatar
Rotary Enthusiast
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 1,025
Likes: 4
From: Huntington Beach, CA, USA
Whoops I double checked and the Koyo is 55mm, not 52mm.
Reply