3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

FD suddenly and without warning, won't start...

Thread Tools
 
Search this Thread
 
Old Jan 10, 2016 | 09:06 PM
  #1  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
FD suddenly and without warning, won't start...

Hey guys,

I knew it'd only be a matter of time before I posted a thread like this here. I didn't anticipate it would be less than a month into ownership, but here we are.

So... I needed to buy a DIN removal tool to take out my radio, cause my wideband is giving me an error and I have to access the back of it.

I start the car up today - let it warm up like normal - after water and oil are about 110*-120*F, I start driving it nice and easy. I wait till both water and oil are at/above about 160*F. I give it full throttle in third revving from about 3500 rpm's to about 7000 rpm's and let off as I approach some slower traffic.

Pull up to the stop light, everything is perfect. Drive to Best Buy about 5-7 minutes away, everything is perfect. Get there, go inside for about 10 minutes. Start the car in the lot easy peazy, everything is running perfect. Drive the car around back to speak with the car audio guys. Cars turned off for 10 maybe 15 minutes. Go to start it and it won't start.

Starter spun just fine, motor even started for a moment but wouldn't idle and I couldn't keep it going even with pushing the gas a bit. Tried it again same thing. So, I'm thinking it must be flooded some how. I sit there for about 15 minutes, this time I try to start with the gas pedal floored, to try to deflood a bit. Try it again without the gas pedal and nothing. Cranks, cranks, cranks but won't catch.

Pushed the car into the Best Buy bay and the super cool guys hooked up a battery charger to my battery so I could try again with stronger cranking power. After another 15-20 minutes, same exact results.

At this point I've convinced myself it must be flooded. So, I pull the two trailing plugs and they are dry. Had my wife bring me new plugs from the store and put them in. Nothing. Crank crank, no start. I had to tow it home.

I am baffled. Why the car would start moments prior and run perfectly, giving no warning or any sort of strangeness in its idle or anything, beats the hell out of me.

I'm totally confused. Any input would be much appreciated.

As a side note, last night I did have to drive home from a meet in some pretty heavy rain but I don't know how that would or could have effected the car. Especially when it ran fine today, just minutes prior to this. Anyone else have a similar experience??

Thank you!

Nick

Last edited by Brilliant7-LFC; Jan 10, 2016 at 09:09 PM.
Reply
Old Jan 10, 2016 | 09:29 PM
  #2  
Fritz Flynn's Avatar
All out Track Freak!
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (263)
 
Joined: Jul 2001
Posts: 10,672
Likes: 413
From: Charlottesville VA 22901
check the plug and wiring to the igniter and make sure they are good

Check the fuel pump fuse. The one in the fuse box behind the drivers side kick panel.

How modified is the car? Does the car have a j and s knock sensor?
Reply
Old Jan 10, 2016 | 09:36 PM
  #3  
Houstonderk's Avatar
My girl
Tenured Member 15 Years
iTrader: (3)
 
Joined: Apr 2004
Posts: 2,173
Likes: 3
From: Andrews AFB, MD
Gotta start with the basics.. fuel,spark,compression
Maybe check for codes as well.
Reply
Old Jan 10, 2016 | 10:19 PM
  #4  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by Fritz Flynn
check the plug and wiring to the igniter and make sure they are good

Check the fuel pump fuse. The one in the fuse box behind the drivers side kick panel.

How modified is the car? Does the car have a j and s knock sensor?
Thanks for the help Fritz.

The car has an A Spec GT40 single kit, all supporting mods. Motor is street ported, built by Kilo. I was actually planning to take it to him in the morning anyway to get a boost issue worked out. Now, I've got this...

I will check the fuse as that seems to me the most likely, I had it in mind to check tomorrow morning anyhow but didn't want to mess with it tonight.

The circumstances are what's throwing me off. All of these things are possibilities but how/why would it be running flawlessly and then after shutting off for 10 minutes, it give me this problem?? That's what's got me scratching my head.

You hear plenty of stories about how the car started to run like **** or that it wouldn't idle or whatever. The car was PERFECT, until it suddenly wasn't. That's what's so damn confusing...

Nick
Reply
Old Jan 10, 2016 | 10:21 PM
  #5  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by Houstonderk
Gotta start with the basics.. fuel,spark,compression
Maybe check for codes as well.
Thanks for the feedback dude. I am going to start tackling this list in the morning. I was hoping to get an idea before diving in. Was hoping someone else had this issue at some point.

Car has a Microtech LT-10 so not sure how to check the codes on it.

Nick
Reply
Old Jan 10, 2016 | 10:45 PM
  #6  
furious_rotation's Avatar
Full Member
Tenured Member 10 Years
 
Joined: Jul 2005
Posts: 86
Likes: 0
From: Utah
Potential issues with the fuel pump could extend past a blown fuse as well. Had a guy here in Utah, a few months ago, who's car exhibited the same issues as yours. Turned out that his WB 255 had sucked the sock material through the pump and ruined its internals.
Reply
Old Jan 10, 2016 | 11:16 PM
  #7  
Neutron's Avatar
Senior Member
Tenured Member: 10 Years
Liked
Loved
Community Favorite
iTrader: (10)
 
Joined: Jul 2011
Posts: 664
Likes: 94
From: AZ
Do you have aftermarket coils? I had a blown fuse to my AEM smart coils which exhibited this exact behavior. My bet is ignition or fuel pump fuse.
Reply
Old Jan 11, 2016 | 07:42 AM
  #8  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by furious_rotation
Potential issues with the fuel pump could extend past a blown fuse as well. Had a guy here in Utah, a few months ago, who's car exhibited the same issues as yours. Turned out that his WB 255 had sucked the sock material through the pump and ruined its internals.
I have a couple spare fuel pumps that came with the car. Any way to test for this outside of removing it?

Nick
Reply
Old Jan 11, 2016 | 07:43 AM
  #9  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by Neutron
Do you have aftermarket coils? I had a blown fuse to my AEM smart coils which exhibited this exact behavior. My bet is ignition or fuel pump fuse.
Mazda coils.

Heading out to the garage now to check them out.

Nick
Reply
Old Jan 11, 2016 | 09:28 AM
  #10  
Houstonderk's Avatar
My girl
Tenured Member 15 Years
iTrader: (3)
 
Joined: Apr 2004
Posts: 2,173
Likes: 3
From: Andrews AFB, MD
Fuel pressure gauge for the line at the engine, and timing light on plug wire. Checks fuel pressure and spark.
Reply
Old Jan 11, 2016 | 09:53 AM
  #11  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Update

Looked at several fuses, everything's good. Wanted to rule out the flooding thing so I pulled the EGI fuse, cranked it for 15 seconds with the gas pedal fully pressed. Repeated this a minute later. Then, tried to start it normally and got nothing.

Called a good friend and rotary mechanic and he asked me about my fuel pressure - it didn't make sense to him that my plugs were so dry when I pulled them.

Low and behold, I've got "0.0" on my SPA electronic gauge and my Aeromotive FPR reads dead 0 as well.

So, I pull both lines from the tank, under the rear carpet - and the hose on the passenger side dribbles out only a few drops of fuel. The line to drivers side, when pulled, had zero fuel come out of it. Then, with both lines disconnected I cranked the engine (well my wife did) and no fuel came from either of the lines.

Next step is to determine if the fuel pump is the issue or the Microtech perhaps not sending the signal to it.

I do have a spare fuel pump, it's from Rotary Performance and when speaking to them, they insist they rarely go bad so I may try that pump out instead.

For now, I've got to go to work...

Nick
Reply
Old Jan 11, 2016 | 11:18 AM
  #12  
Fritz Flynn's Avatar
All out Track Freak!
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (263)
 
Joined: Jul 2001
Posts: 10,672
Likes: 413
From: Charlottesville VA 22901
Originally Posted by MiamiFD3S
Looked at several fuses, everything's good. Wanted to rule out the flooding thing so I pulled the EGI fuse, cranked it for 15 seconds with the gas pedal fully pressed. Repeated this a minute later. Then, tried to start it normally and got nothing.

Called a good friend and rotary mechanic and he asked me about my fuel pressure - it didn't make sense to him that my plugs were so dry when I pulled them.

Low and behold, I've got "0.0" on my SPA electronic gauge and my Aeromotive FPR reads dead 0 as well.

So, I pull both lines from the tank, under the rear carpet - and the hose on the passenger side dribbles out only a few drops of fuel. The line to drivers side, when pulled, had zero fuel come out of it. Then, with both lines disconnected I cranked the engine (well my wife did) and no fuel came from either of the lines.

Next step is to determine if the fuel pump is the issue or the Microtech perhaps not sending the signal to it.

I do have a spare fuel pump, it's from Rotary Performance and when speaking to them, they insist they rarely go bad so I may try that pump out instead.

For now, I've got to go to work...

Nick
Clearly fuel pump isn't getting power. Solve that and you fixed the issue

Probably hack job fuel pump wiring bypass job
Reply
Old Jan 11, 2016 | 11:41 AM
  #13  
MattGold's Avatar
Form > Function
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (116)
 
Joined: Dec 2003
Posts: 1,990
Likes: 236
From: Metro Detroit
Replace that fuel pump fuse anyhow, that was my first instinct too. I've been on long drives and had it heat up and "melt" more then "pop". If you don't pay particular attention, it might look like it's fine but actually be done.

No better feeling then discovering it's a $.10 problem.
Reply
Old Jan 11, 2016 | 01:15 PM
  #14  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by Fritz Flynn
Clearly fuel pump isn't getting power. Solve that and you fixed the issue

Probably hack job fuel pump wiring bypass job
Yeah, hopefully it's relatively simple and not expensive.

I did notice a Bosch relay wired into the fuel pump's wiring, looked a little simple in nature. In speaking to the builder he says that relay goes into the car's factory wiring, if I remember correctly.

Nick
Reply
Old Jan 11, 2016 | 01:30 PM
  #15  
MattGold's Avatar
Form > Function
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (116)
 
Joined: Dec 2003
Posts: 1,990
Likes: 236
From: Metro Detroit
Oh, sounds like the previous owner did a rewire:

https://www.rx7club.com/3rd-generati...ty-mod-615964/

https://www.rx7club.com/3rd-generati...l-pump-847009/

Common stuff.
Reply
Old Jan 11, 2016 | 01:36 PM
  #16  
Monsterbox's Avatar
Mazzei Formula
iTrader: (6)
 
Joined: Jun 2006
Posts: 3,021
Likes: 145
From: Birmingham, Al
Gotta be careful with the rewire, as these pumps can overheat fuses/relays if you don't use beefy enough wiring/switches.

I've had two failures to date.

1. melted a fuse holder for 30amp, even having used 12 gauge wiring

2. upgraded that wiring and fuse holder, and next failure was longacre 30 amp switch just literally broke

3. fixed the switch, added a relay, all is good and then the PINS on the fuel pump bulk head connector burned up!

LOL

Solution was direct 10 gauge wire, directly to the fuel pump w/ spade connector, immediately into an 80AMP relay, then directly to the battery!

The pump was a walbo 400. Not sure how or why it burned everything in its path!
Reply
Old Jan 11, 2016 | 04:00 PM
  #17  
MK3Brent's Avatar
I'm only asking questions
Tenured Member 05 Years
iTrader: (6)
 
Joined: Jul 2010
Posts: 498
Likes: 23
From: Greensboro, North Carolina
An easy test to do before removing the access panel and removing the pump is to check for voltage to the wiring connector at the pump's wiring harness.
Just clip on your leads to the source side of the harness, and watch the multimeter while cranking.


This will test if you have a 0V problem, or a fuel pump problem.
Reply
Old Jan 11, 2016 | 04:01 PM
  #18  
MK3Brent's Avatar
I'm only asking questions
Tenured Member 05 Years
iTrader: (6)
 
Joined: Jul 2010
Posts: 498
Likes: 23
From: Greensboro, North Carolina
By the way.... You do have fuel in the tank, yes?
Reply
Old Jan 11, 2016 | 04:06 PM
  #19  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by MK3Brent
By the way.... You do have fuel in the tank, yes?
How insulting. Yes, it's got half a tank of pre-mixed 93 ready to be burned! Will try to test when I get home tonight. I won't be out till 9PM though...

Nick

Last edited by Brilliant7-LFC; Jan 11, 2016 at 10:55 PM.
Reply
Old Jan 11, 2016 | 04:12 PM
  #20  
Houstonderk's Avatar
My girl
Tenured Member 15 Years
iTrader: (3)
 
Joined: Apr 2004
Posts: 2,173
Likes: 3
From: Andrews AFB, MD
It's always something to check. For some reason my gauge goes to a smidge below a 1/4 tank and fuel pressure starts cutting out. Have to check mine out as well.
Reply
Old Jan 11, 2016 | 10:12 PM
  #21  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Don't cut the red wire!!

Good news is, the Microtech lights up! So, I know it isn't dead which is a good thing.

Ok, so I'm discovering I wouldn't make it on the bomb squad.

So, here's as far as I can figure out...

- Red wire coming off the battery (unconfirmed) splices to orange wire with inline fuse holder and 20 amp fuse -- this wire terminates in the relay

- Wire harness from car has a red/white (thicker gauge), green/white and blue wire

- Green/white and blue wire remain unaltered and terminate at fuel pump clip

- Red/white wire has been spliced to pink which terminates in the relay

- Red cable out of relay splits to red/white wire and black wire, which both terminate at fuel pump clip

- Green wire from relay terminates at grounding point

Now as far as I can work out, I assumed the thicker gauge red/white wire would be power and the green would be ground.

Then I notice the mystery black wire and I'm confused.

I am not sure which to test. I tested my tester on my battery and got 12v so it should be accurate. In playing around with it, I couldn't get a solid reading from the pins but perhaps I didn't jam it into the holes far enough? I did get one of them to read 12v while grounding to the grounding point pictured. Not sure which one... Any advice?

Pics:











Nick
Reply
Old Jan 12, 2016 | 01:47 AM
  #22  
ZE Power MX6's Avatar
Boilermakers!
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (169)
 
Joined: Nov 2002
Posts: 3,767
Likes: 375
From: Chicago, IL
Yuck, that's some messy wiring.

The green/white and blue wire are for fuel level, red/white is pump power, black just ground. To test power, turn ignition to ON and jump the F/P and GND pin in the diagnosis box, and you should see 12V at the 4-pin connector on red/white wire. If not then you need to check to see if you are getting 12V signal to the relay (red/white wire on the harness side), next would be that fuse with orange wire, then the relay or the pump itself.

I would suggest redoing the wiring, find a better place for the relay and that fuse should really be as close to the source as possible.
Reply
Old Jan 12, 2016 | 06:13 AM
  #23  
ZoomZoom's Avatar
SEMI-PRO
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (2)
 
Joined: Feb 2001
Posts: 2,865
Likes: 36
From: New Jersey
Did you inspect the bulkhead connector? I know it was suggested but didn't see a response from you. I've burned these up before and replaced them with a Racetronix unit. Here is what a burned up bulkhead connector looks like.
Name:  BC9D8886-18B9-4C41-A9C6-BC231CD423FF.jpg
Views: 1407
Size:  138.8 KB
Name:  236BDC00-8306-44A9-8C89-CA1AC53D1AAC.jpg
Views: 1384
Size:  68.0 KB
Name:  89F87FE7-AC37-4430-854F-414A22200575.jpg
Views: 1402
Size:  63.1 KB
Reply
Old Jan 12, 2016 | 06:40 AM
  #24  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by ZE Power MX6
Yuck, that's some messy wiring.

The green/white and blue wire are for fuel level, red/white is pump power, black just ground. To test power, turn ignition to ON and jump the F/P and GND pin in the diagnosis box, and you should see 12V at the 4-pin connector on red/white wire. If not then you need to check to see if you are getting 12V signal to the relay (red/white wire on the harness side), next would be that fuse with orange wire, then the relay or the pump itself.

I would suggest redoing the wiring, find a better place for the relay and that fuse should really be as close to the source as possible.
Yeah I was less than impressed myself. I was considering redoing the whole thing while I'm at it. Once this has been fully diagnosed, I will reference those two threads posted in here earlier.

Wiring and electricity are not my specialities So, please help clarify for me: "jump the F/P and GND pin in the diagnosis box" -- are you saying to take a wire and connect the F/P and GND so they make a circuit? Forgive my ignorance and, thank you for the direction...

Nick
Reply
Old Jan 12, 2016 | 06:42 AM
  #25  
Brilliant7-LFC's Avatar
Thread Starter
Senior Member
Tenured Member: 20 Years
Liked
iTrader: (7)
 
Joined: Sep 2004
Posts: 694
Likes: 31
From: Miami, FL
Originally Posted by ZoomZoom
Did you inspect the bulkhead connector? I know it was suggested but didn't see a response from you. I've burned these up before and replaced them with a Racetronix unit. Here is what a burned up bulkhead connector looks like.
Where is the bulkhead connector? I don't see it or remember seeing it when working in the area...?

I'll check it out along with the wiring mentioned above tonight after work.

Thank you!

Nick
Reply



All times are GMT -5. The time now is 12:17 AM.