doing Vacuum hoses, is it possible to use American size hoses?
doing Vacuum hoses, is it possible to use American size hoses?
Ok, i'm short on time and can't wait for 4 and 6mm hoses to arrive. I'm wondering if i can use American size silicone hose in inch unit measure?
4mm = .16 inches
6mm = .24 inches
The inside diameter of the american inch silicone hose is 5/16 which is equivalent to .156 inches and the 1/4 is obviously equivalent to .25 inches. I don't forsee a problem with the 4mm hoses, but the 1/4 is obviously bigger than the 6mm. Would this pose a problem? Fitment issues? I can have the hoses by tonight if the inch unit measure hoses can be used for the vacuum hose replacement.
D.
4mm = .16 inches
6mm = .24 inches
The inside diameter of the american inch silicone hose is 5/16 which is equivalent to .156 inches and the 1/4 is obviously equivalent to .25 inches. I don't forsee a problem with the 4mm hoses, but the 1/4 is obviously bigger than the 6mm. Would this pose a problem? Fitment issues? I can have the hoses by tonight if the inch unit measure hoses can be used for the vacuum hose replacement.
D.
Except for the few hoses that attach to a barbed fitting, zip-tying the hoses is unnecessary.
As far as hose size goes, your math is pretty far off there....
1/8" = 0.125 = 3.2mm
5/32" = 0.15625 = 4mm
3/16" = 0.1875 = 4.8mm
7/32" = 0.21875 = 5.6mm
1/4" = 0.25 = 6.35mm
5/16" = 0.3125 = 7.9mm
As far as hose size goes, your math is pretty far off there....
1/8" = 0.125 = 3.2mm
5/32" = 0.15625 = 4mm
3/16" = 0.1875 = 4.8mm
7/32" = 0.21875 = 5.6mm
1/4" = 0.25 = 6.35mm
5/16" = 0.3125 = 7.9mm
Rynberg, you're right. That is the second time today that i called 5/32 5/16 instead. In my original post, i meant to say 5/32. Sorry for the confusion. I've dealt with too many numbers today
Thanks for the information guys! It looks like i will be getting the 5/32 and 1/4" silicone hoses.
Darril
Thanks for the information guys! It looks like i will be getting the 5/32 and 1/4" silicone hoses.
Darril
All my hoses are 4mm and 6mm silicone from Baker Precision and I never zip tied any of them though I did reuse the metal spring clamps on things like the wastegate and precontrol actuators. Never blown a single one off in god knows how many race events.
Most of them even survived fire
Most of them even survived fire
Thread
Thread Starter
Forum
Replies
Last Post
Jeff20B
1st Generation Specific (1979-1985)
73
Sep 16, 2018 07:16 PM
[For Sale] Scratch & Dent, Used, and Open-Box Sale!
SakeBomb Garage
Vendor Classifieds
5
Aug 9, 2018 05:54 PM
rx8volks
Canadian Forum
0
Sep 1, 2015 11:02 PM







