3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Cooling Fans and Purge Solenoid Prolem

Thread Tools
 
Search this Thread
 
Old 11-17-09, 10:41 AM
  #1  
Eye In The Sky

Thread Starter
iTrader: (2)
 
cewrx7r1's Avatar
 
Join Date: Feb 2001
Location: In A Disfunctional World
Posts: 7,893
Likes: 0
Received 114 Likes on 66 Posts
Cooling Fans and Purge Solenoid Prolem

Auto FD story made short:

The engine had problems and the owner tried swapping ECUs and the trans control box. The engine had a water seal failure problem.

After installing a NEW Mazda engine and new harness into the automatic, the engine started effortlessly. But; the fans would run continuously and the purge solenoid would cycle, both with the engine off and key removed with a cold engine.

The 93 manuals show that the fans only get coil control 12V with the key on through a 15 fuse. They do not show the black fan control box.

The 94 manuals show the black box in the functionality view and fan relay control view, but still has the 93 wiring schematic which does not show the box.

I could not find a 95 manual with what I needed.

When I pulled the 15 A fuse and the black box, both problems still happened.
Swapped out the ecu with a another stock and a PFC, problem still there.
Swapped out the auto trans control unit, problem went away!

Mazda's manuals are really very very bad!!!!!!!!!!!
Old 11-17-09, 12:04 PM
  #2  
Form follows function

iTrader: (8)
 
Speed of light's Avatar
 
Join Date: Oct 2004
Location: Now in Arizona
Posts: 1,203
Received 33 Likes on 21 Posts
The Fan control module is used with an ECU harness adaptor and a replacement fan harness, which is not reflected in the earlier FSM's as far as I know....it's in one of their TSB's or the recall document, IIRC.
Old 11-17-09, 12:11 PM
  #3  
rotorhead

iTrader: (3)
 
arghx's Avatar
 
Join Date: Aug 2004
Location: cold
Posts: 16,182
Received 429 Likes on 263 Posts
Interesting. It must be some kind of mismatched wiring between years.
Old 11-17-09, 12:17 PM
  #4  
Eye In The Sky

Thread Starter
iTrader: (2)
 
cewrx7r1's Avatar
 
Join Date: Feb 2001
Location: In A Disfunctional World
Posts: 7,893
Likes: 0
Received 114 Likes on 66 Posts
Originally Posted by Speed of light
The Fan control module is used with an ECU harness adaptor and a replacement fan harness, which is not reflected in the earlier FSM's as far as I know....it's in one of their TSB's or the recall document, IIRC.
A new std and auto wiring harness have the new wiring included for the fan black box and do not require the jumper used with the original harness.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Bauer778
3rd Generation Specific (1993-2002)
10
11-04-15 04:42 PM
alexdimen
3rd Generation Specific (1993-2002)
20
10-23-15 01:50 PM
High_Carb_Diet
Power FC Forum
1
09-05-15 09:07 AM



Quick Reply: Cooling Fans and Purge Solenoid Prolem



All times are GMT -5. The time now is 06:27 AM.