3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

air pump not working

Old Mar 26, 2002 | 11:23 PM
  #1  
now's Avatar
now
Thread Starter
Rotary Freak
Tenured Member 10 Years
iTrader: (1)
 
Joined: Apr 2001
Posts: 1,825
Likes: 4
From: alberta, canada
air pump not working

Ok i have tested the air pump, it is ok, the relay
is ok and all the wiring is ok, but the air pump will not come on at idle of any other time for that matter.
So i grounded the wire at the computer and the air pump comes on, so the computer is not grounding the relay to turn on the air pump.
what would cause the computer not to turn on the
air pump?
I cant test for codes, so don't suggest that, why?
you ask, well, this isn't exactly a 3rd gen, but it's really close if you compare the wiring diagrams, what i am working on is a 20b, with all the 20b wiring, computer, and trani, and for some reason the computer is not switching on the air pump, so i thought i would ask if anyone here knows what would make a 3rd gen's computer not turn on the air pump.

thanks
matt
Reply
Old Mar 26, 2002 | 11:36 PM
  #2  
spooledUP7's Avatar
There and back again
Tenured Member 15 Years
 
Joined: Feb 2001
Posts: 967
Likes: 0
From: Camarillo, Ca
There could be another harness connector which may not be connected. I would clean the contacts on the harnesses to be sure there is continuity. Check for continuity from the ECU to the Pump harness connector.
Reply
Old Mar 27, 2002 | 09:01 PM
  #3  
now's Avatar
now
Thread Starter
Rotary Freak
Tenured Member 10 Years
iTrader: (1)
 
Joined: Apr 2001
Posts: 1,825
Likes: 4
From: alberta, canada
Originally posted by spooledUP7
There could be another harness connector which may not be connected. I would clean the contacts on the harnesses to be sure there is continuity. Check for continuity from the ECU to the Pump harness connector.
"So i grounded the wire at the computer and the air pump comes on"
like i said above it comes on which means that
everything is good in the wiring, for some reason the computer is not switching on the air pump.
anyone know what would make the computer not want to turn on the air pump?

matt
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
trickster
2nd Generation Specific (1986-1992)
25
Jul 1, 2023 04:40 PM
alphawolff
1st Generation Specific (1979-1985)
17
Nov 17, 2015 05:57 PM
12abridgeport
1st Generation Specific (1979-1985)
2
Aug 17, 2015 06:28 PM
Wolf_
Single Turbo RX-7's
3
Aug 11, 2015 04:23 PM


Thread Tools
Search this Thread