2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.

turbo oil passage flanges... Buy them where?

Thread Tools
 
Search this Thread
 
Old Jun 22, 2006 | 03:33 PM
  #26  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
after installing the new turbo i trie using the setup i had for the oil drain...BUT because of the way it sat my car smoked like craxy and oil FILLED my exhaust...SO, i want to order or make somthin to fit....should i just braze a 1/2 flare or somthin so it will be more sufficent?
here is what im dealing with now..
should i bother with the T/3 or T/4 flange or whatever it is or cut the stock flange and braze?
Reply
Old Jun 22, 2006 | 03:57 PM
  #27  
The Wankler's Avatar
FKITALL
iTrader: (14)
 
Joined: May 2004
Posts: 3,588
Likes: 2
From: Dublin Ca.
I had the same problem, and yet to fix it.
Reply
Old Jun 22, 2006 | 04:12 PM
  #28  
Digi7ech's Avatar
I break Diff mounts
Tenured Member 20 Years
iTrader: (1)
 
Joined: Jun 2002
Posts: 4,403
Likes: 4
From: Avondale, Arizona
Well,
Your turbo has got to hbe a hybrid and clocked differently from the pic.

If the system worked before then it shoudl now if you only Clock the Compressor cover instead fo the whole cartridge.

Just unbolt the compressor cover and slide it to fit right.

Also, If it's a brand new rebuild then you may not have a restrictore anymore inside the cartridge. Some builders remove the internal restrictor.

This made my car smoke like crazy. Just put a restrictor on the feed line and your set.

Last edited by Digi7ech; Jun 22, 2006 at 04:14 PM.
Reply
Old Jun 22, 2006 | 04:18 PM
  #29  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
lol, actually i have a brake line with fittings for the feed line...im mocking up pic. right now to show all the oil.. i went outside and blown through the feed line (tasted great!!) and it seemed restrictive...and yes it isnt the stock cold side...and i have it turned the way it needs to be because of fitment issues...
Reply
Old Jun 22, 2006 | 04:18 PM
  #30  
The Wankler's Avatar
FKITALL
iTrader: (14)
 
Joined: May 2004
Posts: 3,588
Likes: 2
From: Dublin Ca.
Originally Posted by Digi7ech
Well,
Your turbo has got to hbe a hybrid and clocked differently from the pic.

If the system worked before then it shoudl now if you only Clock the Compressor cover instead fo the whole cartridge.

Just unbolt the compressor cover and slide it to fit right.

Also, If it's a brand new rebuild then you may not have a restrictore anymore inside the cartridge. Some builders remove the internal restrictor.

This made my car smoke like crazy. Just put a restrictor on the feed line and your set.

Yeah, ya know, I have a hybrid and thought about clocking it differently. And, mine did not have a restrictor, and I was gushing oil.(well, almost). ATP Turbo has the right restrictor pills. Now, no more oil blowby.
Reply
Old Jun 22, 2006 | 04:27 PM
  #31  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
here is the outcome i plan on doing....braze a 1/2 pipe or somthin where its mocked up...
and pictures of all the oil i had pouring out of it... i filled my driveway right up!!


Reply
Old Jun 22, 2006 | 04:54 PM
  #32  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
http://www.atpturbo.com/Merchant2/me...egory_Code=OIL
is this the pill your talking about?
Reply
Old Jun 22, 2006 | 04:55 PM
  #33  
Digi7ech's Avatar
I break Diff mounts
Tenured Member 20 Years
iTrader: (1)
 
Joined: Jun 2002
Posts: 4,403
Likes: 4
From: Avondale, Arizona
wow. That's really bad.

Don't run the turbo for long like that before it destroys the front seal or you'll need a rebuild.
Reply
Old Jun 22, 2006 | 04:57 PM
  #34  
Digi7ech's Avatar
I break Diff mounts
Tenured Member 20 Years
iTrader: (1)
 
Joined: Jun 2002
Posts: 4,403
Likes: 4
From: Avondale, Arizona
^yeah that's pretty much what you need.

Somethign to reduce your 60psi oil pressure down to good turbo levels.
Reply
Old Jun 22, 2006 | 05:41 PM
  #35  
The Wankler's Avatar
FKITALL
iTrader: (14)
 
Joined: May 2004
Posts: 3,588
Likes: 2
From: Dublin Ca.
Originally Posted by 88rxn/a
http://www.atpturbo.com/Merchant2/me...egory_Code=OIL
is this the pill your talking about?
the pill size depends on the turbo. Call atp and ask them for the right pill.
Reply
Old Jun 22, 2006 | 09:06 PM
  #36  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
i ran it like that for a total of 5 minutes if that...after the smoke i ripped it out knowing somthin was wrong....
Reply
Old Jun 23, 2006 | 09:04 AM
  #37  
Aaron Cake's Avatar
Engine, Not Motor
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Feb 2001
Posts: 29,798
Likes: 128
From: London, Ontario, Canada
That thing was puking oil! The only one I have see that was worse was a 300ZX that literally had 1/2" of play side to side on the turbine and exhaust wheels...

Anyway, your plan to cut and braze seems fine. If you have never brazed before, both fittings need to be tight as brazing will not easily fill large gaps. Both must be ABSOLUTELY SPOTLESSLY CLEAN. For brazing copper to steel, use a pre-fluxed bronze based rod for this purpose. Heat both equally until cherry red and then apply the rod to the joint. Sometimes you need to heat the rod a little too. The flux will melt and make a lot of smoke and the brazing material should flow into the joint. Don't breath the fumes unless you want to stop living (or at least be very sick for the next few days). When it has cooled, remove any excess flux.
Reply
Old Jun 23, 2006 | 09:33 AM
  #38  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
Originally Posted by Aaron Cake
That thing was puking oil! The only one I have see that was worse was a 300ZX that literally had 1/2" of play side to side on the turbine and exhaust wheels...

Anyway, your plan to cut and braze seems fine. If you have never brazed before, both fittings need to be tight as brazing will not easily fill large gaps. Both must be ABSOLUTELY SPOTLESSLY CLEAN. For brazing copper to steel, use a pre-fluxed bronze based rod for this purpose. Heat both equally until cherry red and then apply the rod to the joint. Sometimes you need to heat the rod a little too. The flux will melt and make a lot of smoke and the brazing material should flow into the joint. Don't breath the fumes unless you want to stop living (or at least be very sick for the next few days). When it has cooled, remove any excess flux.
my neighbors werent to happy with all the smoke!!!!

the shaft play is in very good shape...this one spins 5X's as long as the other and has 1/2 the shaft play....i REALLY need a resistor!! and as far as brazing...my buddy is very good at welding and brazing so he does all the stuff i cant!
Reply
Old Jun 30, 2006 | 11:39 PM
  #39  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
gonna have it welded up tommorow..ill post pictures when im done...
got the pill also and will install it too!!! i will finally have the 7 back on the road!!! hopefully by sunday!
Reply
Old Jul 1, 2006 | 03:54 AM
  #40  
vipers's Avatar
IIMMM BBAAACCKKK!!
Tenured Member 15 Years
iTrader: (8)
 
Joined: Aug 2004
Posts: 2,904
Likes: 1
From: redlands, cali
just posting to save this thread on my list...... need this info soon... thanx for all the posting... great thread
Reply
Old Jul 2, 2006 | 01:02 AM
  #41  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa



here is the outcome..i lwelded this myself and im not the bes but it doesnt leak so it will work
it is a 1/2 inch piece of pipe from the local hardware store.. cost me $2.50 for it..
Reply
Old Jul 2, 2006 | 02:28 AM
  #42  
tinvestor's Avatar
Thread Starter
Rotary Enthusiast
Tenured Member 05 Years
 
Joined: May 2005
Posts: 919
Likes: 0
From: bartlett IL
grind down the weld and hit the entire piece with some paint it will protect the weld and dress the bay a little (even if you choose black) should use high temp paint though.
Reply
Old Jul 2, 2006 | 10:36 AM
  #43  
Aaron Cake's Avatar
Engine, Not Motor
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Feb 2001
Posts: 29,798
Likes: 128
From: London, Ontario, Canada
That will work...What kind of AN fittings are those? They look....rather odd...
Reply
Old Jul 2, 2006 | 11:42 AM
  #44  
88rxn/a's Avatar
tom port.. AKA streetport
Tenured Member 15 Years
iTrader: (6)
 
Joined: Jan 2005
Posts: 4,658
Likes: 0
From: ludlow, pa
its a 10 AN NPT to 1/2 inch AN fitting i got from JEGS...
and as far as paiting im doing that today....
the red AN fitting was from JEGS too but i cant remember which one it is..
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
trickster
2nd Generation Specific (1986-1992)
25
Jul 1, 2023 04:40 PM
ChrisRX8PR
Single Turbo RX-7's
18
Aug 21, 2015 01:56 PM




All times are GMT -5. The time now is 07:51 AM.