S5 NA auto: starter fluid starts it then stays on BUT cannot self start!

Thread Tools
 
Search this Thread
 
Old 07-16-07, 09:51 PM
  #1  
Banned. I got OWNED!!!
Thread Starter
 
--MAstermind--'s Avatar
 
Join Date: May 2004
Location: San Antonio
Posts: 778
Likes: 0
Received 0 Likes on 0 Posts
S5 NA auto: starter fluid starts it then stays on BUT cannot self start!

i was wondering if anyone knew anything about that? supposedly if ya spray starter fluid the FC starts, and runs... but it doesn't start without it...so I'm pretty confused on that....once it starts it goes through accelerated warm up and then holds 1k idle... its an auto.. i was just wondering if anyone knew what that could be?

things i KNOW

fuel pump checks ok
all vac lines check ok
has 135,XXXmiles


any pointers would be great!
thanks!!!
Old 07-17-07, 12:35 AM
  #2  
Lives on the Forum

iTrader: (8)
 
RotaryResurrection's Avatar
 
Join Date: Oct 2003
Location: Morristown, TN (east of Knoxville)
Posts: 11,576
Received 25 Likes on 18 Posts
bet you can't say the thread title 5 times fast.

Sounds like a weak compression engine that is flooding on startup. Auto's have a harder time getting started due to the extra mass of the torque convertor, pump, and fluid, and a borderline compression engine will just make this issue worse.

I have rebuilt MANY an s5 auto engine with 50-80k miles on the engine due to carbon buildup and weak compression that wouldn't let the car reliably restart.
Old 07-17-07, 04:05 AM
  #3  
Registered Loser

iTrader: (6)
 
walken's Avatar
 
Join Date: Dec 2002
Location: Whiterock
Posts: 2,224
Likes: 0
Received 0 Likes on 0 Posts
fresh spark plugs sometimes help
Old 07-17-07, 07:12 PM
  #4  
Automatic = Power drain

 
NoDOHC's Avatar
 
Join Date: Nov 2006
Location: Pennsylvania
Posts: 399
Likes: 0
Received 0 Likes on 0 Posts
The start position coil in the fuel pump relay may be bad (requiring air flow to start.)

Thats my only guess other than poor compression.
Old 07-18-07, 03:29 PM
  #5  
Banned. I got OWNED!!!
Thread Starter
 
--MAstermind--'s Avatar
 
Join Date: May 2004
Location: San Antonio
Posts: 778
Likes: 0
Received 0 Likes on 0 Posts
well thanks guys ill give her a compression test... i bit my tounge saying it ....ill keep ya guys posted...

where might this fuel pump relay be? the one under the dash? thanks for the help! ill also try the new plugs and see if.... i thought if it was flooeded though that the engine would only stay flooded due to MORE starter fluid.. either way all your comments are a great direction ill be back.....
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Kyo
2nd Generation Specific (1986-1992)
6
04-13-19 09:24 AM
gxl90rx7
Haltech Forum
4
09-14-15 03:09 PM
ray green
1st Gen General Discussion
2
09-02-15 06:35 AM



Quick Reply: S5 NA auto: starter fluid starts it then stays on BUT cannot self start!



All times are GMT -5. The time now is 04:48 AM.