Max that the stock feul rail will hold?

I want to know what the maximum the stock feul rails in a S5 TII will hold. Yes they will be controlled not sure what but i want to put 4 820cc injectors is this duable? witht he stock rails? i need lots more feul for my T04 and well i am trying to make a shopping list for what i will need when i put my car back together! Any tips hints or advice?
Reply
Old Sep 20, 2002 | 01:50 PM
  #2  
darkwaveboi's Avatar
Need donor car in Fairfax
Tenured Member 05 Years
 
Joined: Nov 2001
Posts: 1,759
Likes: 0
From: Northern Virginia
im not completely sure but i think 720 or 800 are the max...
Reply
Old Sep 20, 2002 | 03:10 PM
  #3  
DaleClark's Avatar
RX-7 Bad Ass
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (56)
 
Joined: Jan 2002
Posts: 15,622
Likes: 2,725
From: Pensacola, FL
Many Haltech guys use 550cc primaries and 1600cc secondaries.

I don't know at what point the stock fuel rails become a problem. That's what fuel pressure gauges are for . Probably somewhere north of 400hp would be my guess.

Dale
Reply
Old Sep 20, 2002 | 11:56 PM
  #4  
jreynish's Avatar
Thread Starter
New Project on the Way...
Tenured Member: 20 Years
iTrader: (2)
 
Joined: Apr 2002
Posts: 3,764
Likes: 6
From: Yellowknife, NT
well i Need at least 800cc in both primaries and secondaries! and i do not have a haltech as i cannot afford it! and i do not have a stock turbo to put back onto my car! so I Am looking at the Greddy e-manage and 820cc is the biggest i can put in! so i figured that i would ask if anybody knew what the max that the stock feul rails would handle. So if anybody knows let me know!
Reply
Old Sep 20, 2002 | 11:57 PM
  #5  
jreynish's Avatar
Thread Starter
New Project on the Way...
Tenured Member: 20 Years
iTrader: (2)
 
Joined: Apr 2002
Posts: 3,764
Likes: 6
From: Yellowknife, NT
oh sorry and i will be running somewhere in the region of 400-450hp by the time i am done!
Reply
Old Sep 21, 2002 | 01:03 AM
  #6  
RETed's Avatar
Lives on the Forum
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 26,664
Likes: 22
From: n
500hp is about the limit.&nbsp I would worry about the 5/16" hard metal fuel lines more than the fuel rails itself...


-Ted
Reply
Old Sep 21, 2002 | 10:05 PM
  #7  
jreynish's Avatar
Thread Starter
New Project on the Way...
Tenured Member: 20 Years
iTrader: (2)
 
Joined: Apr 2002
Posts: 3,764
Likes: 6
From: Yellowknife, NT
Originally posted by RETed
500hp is about the limit.&nbsp I would worry about the 5/16" hard metal fuel lines more than the fuel rails itself...
Care to elaborate? Because i need to know! so i can put like 820cc in both the primaries and secondaries? and it will work? but what is this about the feul lines you speak of?
Reply
Old Sep 23, 2002 | 09:24 PM
  #8  
RETed's Avatar
Lives on the Forum
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 26,664
Likes: 22
From: n
The car uses 5/16" hard metal lines from the gas tank to the front before the fuel filter.&nbsp I recommend changing them to min -6 AN SS lines if you're shooting over 500hp from the engine.

For your application, the stock stuff sounds fine.


-Ted
Reply
Old Sep 23, 2002 | 11:32 PM
  #9  
Scott 89t2's Avatar
SOLD THE RX-7!
Tenured Member 10 Years
 
Joined: Mar 2001
Posts: 7,451
Likes: 0
From: Vancouver, BC, Canada
Originally posted by jreynish
oh sorry and i will be running somewhere in the region of 400-450hp by the time i am done!
on stock ecu?

but as for injectors.. I don't know of anything that size. lots use 720's in the stock rails. the 1600's need to have the rail modified to fit them. I don't know of anything inbetween that will fit in the stock rails..
Reply
Old Sep 23, 2002 | 11:57 PM
  #10  
Rpeck's Avatar
What R U thinking self?
Tenured Member 05 Years
 
Joined: Mar 2002
Posts: 2,333
Likes: 0
From: Stockton, CA
I have 1000cc Secondaries in my stock secondary rails. I had a set of stock 550cc injectors inlarged so i would not have to deal with the impeadance factor, my injectors are high imp. Hard to find them in a large format. I use a S-AFC ... so with +50 being max, i wanted some tuning room so i went 1000, instead of 1100.
Reply
Old Sep 24, 2002 | 12:11 AM
  #11  
Scott 89t2's Avatar
SOLD THE RX-7!
Tenured Member 10 Years
 
Joined: Mar 2001
Posts: 7,451
Likes: 0
From: Vancouver, BC, Canada
Originally posted by Rpeck
I have 1000cc Secondaries in my stock secondary rails. I had a set of stock 550cc injectors inlarged so i would not have to deal with the impeadance factor, my injectors are high imp. Hard to find them in a large format. I use a S-AFC ... so with +50 being max, i wanted some tuning room so i went 1000, instead of 1100.
wow they made them from 550 to 1000? was that at RC ? I was thinking about doing something like that since there are no bolt in's for the S5's...
Reply
Old Sep 24, 2002 | 12:15 AM
  #12  
Rpeck's Avatar
What R U thinking self?
Tenured Member 05 Years
 
Joined: Mar 2002
Posts: 2,333
Likes: 0
From: Stockton, CA
Yup it was RC, they said they can usally go %50 over. that would put them max at 1100, but like I said I wanted some tuneabilty so i stopped at 1000. Or else I would have to set the S-AFC at max, and have nothing to work with.

NOT cheap though. $180 per injector! but nothing considering the gains.. and all the other money i spend on this thing ... you know what I mean
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
immanuel__7
2nd Generation Specific (1986-1992)
89
Sep 5, 2015 10:23 AM
Snook
3rd Generation Specific (1993-2002)
12
Aug 15, 2015 08:18 AM
Alan777
3rd Generation Specific (1993-2002)
1
Aug 13, 2015 02:47 AM




All times are GMT -5. The time now is 01:40 PM.