2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

Leading Spark issue

Thread Tools
 
Search this Thread
 
Old 06-15-07, 09:42 AM
  #1  
FKITALL

Thread Starter
iTrader: (14)
 
The Wankler's Avatar
 
Join Date: May 2004
Location: Dublin Ca.
Posts: 3,589
Likes: 0
Received 2 Likes on 2 Posts
Leading Spark issue

I seem to be haing a spark issue. Yesterday, I was installing a E-Fan. I had also just installed my Crane Hi-6 Ignition. The car ran great on the new ignition. Soon after installing the EFan, my problems began. Its a Taurus E Fan FYI. After properly installing the fan, my ignition seems to stop working. I seem to be getting lazy spark? I swapped out my Crane ignition for the OEM one. Same thing. Seems to be little no spark. It sparks like once twice a second. I am getting power to the ignitors. It does give some spark, just not much. Any ideas?
Old 06-15-07, 10:03 AM
  #2  
FKITALL

Thread Starter
iTrader: (14)
 
The Wankler's Avatar
 
Join Date: May 2004
Location: Dublin Ca.
Posts: 3,589
Likes: 0
Received 2 Likes on 2 Posts
I just cranked over the car for 5 seconds. Pulled the leading plug. Shouldn't there be some wet gas on the plug? Dry as a bone.
1. little to no spark. Pulled the plug to look for spark. All I see is one single spark coming from the plug, then nada.

2. Plugs not getting wet.

Last edited by The Wankler; 06-15-07 at 10:12 AM.
Old 06-15-07, 10:24 AM
  #3  
Seduced by the DARK SIDE

 
SureShot's Avatar
 
Join Date: Apr 2001
Location: Orange Park FL (near Jax)
Posts: 7,323
Likes: 0
Received 2 Likes on 2 Posts
Is you fan load current source to the relay comming off the battery or from IG1?
Old 06-15-07, 12:16 PM
  #4  
FKITALL

Thread Starter
iTrader: (14)
 
The Wankler's Avatar
 
Join Date: May 2004
Location: Dublin Ca.
Posts: 3,589
Likes: 0
Received 2 Likes on 2 Posts
The main red wire is coming off the battery.

I have the fan disonnected right now.
Old 06-15-07, 12:53 PM
  #5  
FKITALL

Thread Starter
iTrader: (14)
 
The Wankler's Avatar
 
Join Date: May 2004
Location: Dublin Ca.
Posts: 3,589
Likes: 0
Received 2 Likes on 2 Posts
Just swapped in another ECU, no change. I bet this is something real supid...
Old 06-15-07, 02:42 PM
  #6  
Seduced by the DARK SIDE

 
SureShot's Avatar
 
Join Date: Apr 2001
Location: Orange Park FL (near Jax)
Posts: 7,323
Likes: 0
Received 2 Likes on 2 Posts
I'd start by checking the switch-on voltage in IG1 & IG2.
Old 06-15-07, 03:00 PM
  #7  
FKITALL

Thread Starter
iTrader: (14)
 
The Wankler's Avatar
 
Join Date: May 2004
Location: Dublin Ca.
Posts: 3,589
Likes: 0
Received 2 Likes on 2 Posts
I get 12v up to the main relay. But from there to the coils, nada. I do not get any voltage at the cpu as well. Could the Mian Relay cause this? I also just realized, I had a couple wires backwards when I wired the Crane Ignition in. The ones that go to the Main Relay.
Old 06-15-07, 03:13 PM
  #8  
Seduced by the DARK SIDE

 
SureShot's Avatar
 
Join Date: Apr 2001
Location: Orange Park FL (near Jax)
Posts: 7,323
Likes: 0
Received 2 Likes on 2 Posts
Bingo - you're on it.
Either the main relay has a problem or it's stator coil not getting energized.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
rgordon1979
3rd Generation Specific (1993-2002)
40
03-15-22 12:04 PM
Jeff20B
1st Generation Specific (1979-1985)