2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

FD UIM on s4 TII OMP question

Thread Tools
 
Search this Thread
 
Old 08-24-08, 01:45 PM
  #1  
Full Member

Thread Starter
iTrader: (7)
 
Isam's Avatar
 
Join Date: May 2006
Location: Dayton OH
Posts: 238
Likes: 0
Received 0 Likes on 0 Posts
FD UIM on s4 TII OMP question

So, obviously there is nowhere to connect the omp rod on the fd throttle body. So i have a few questions. Does that rod control oil flow to the block only or the turbo also?
A related question is whether i can just let the rod hang and run premix since that was my plan anyways? I obviously can't let the rod hang if it also controls oil to the turbo, i know.

Also if anyone has a pics of a setup that allows that rod to be connected to the fd uim I'd like to see some.

Yes I searched first.
Old 08-24-08, 09:12 PM
  #2  
rotorhead

iTrader: (3)
 
arghx's Avatar
 
Join Date: Aug 2004
Location: cold
Posts: 16,182
Received 429 Likes on 263 Posts
block off your OMP if you are running the FD TB. your turbo will be unaffected. just make sure to premix.

http://www.banzai-racing.com/products_S4_omp_bop.htm blockoff plate kit
Old 08-25-08, 10:34 AM
  #3  
Full Member

Thread Starter
iTrader: (7)
 
Isam's Avatar
 
Join Date: May 2006
Location: Dayton OH
Posts: 238
Likes: 0
Received 0 Likes on 0 Posts
So i can just take that rod off then also?
Old 08-25-08, 10:36 AM
  #4  
Rotary Freak

iTrader: (14)
 
FrankV702's Avatar
 
Join Date: May 2006
Location: Las Vegas
Posts: 1,575
Received 11 Likes on 6 Posts
Originally Posted by Isam
So i can just take that rod off then also?
Yea, that rod is connected to to your OMP. Take off the OMP, take off the rod, and toss a block off plate on there and run premix.
Old 08-25-08, 12:04 PM
  #5  
Full Member

Thread Starter
iTrader: (7)
 
Isam's Avatar
 
Join Date: May 2006
Location: Dayton OH
Posts: 238
Likes: 0
Received 0 Likes on 0 Posts
great, thanks guys
Old 08-25-08, 02:00 PM
  #6  
Rotary Freak

iTrader: (1)
 
socalrotor's Avatar
 
Join Date: Mar 2003
Location: southbay
Posts: 2,839
Likes: 0
Received 0 Likes on 0 Posts
I don't think this was stated well enough.....IF YOU BLOCK OFF THE OMP, YOU MUST RUN PRE MIX OR BOOM!!!
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
rotor_veux
2nd Generation Specific (1986-1992)
5
09-03-15 07:10 PM



Quick Reply: FD UIM on s4 TII OMP question



All times are GMT -5. The time now is 12:21 PM.